The "Barrier Chamber System" is a PE barrier chamber filled with a non-conductive liquid between two diaphragms to meet advanced safety standards. A sensor for measuring conductivity is attached to monitor the liquid, and if a diaphragm fails and a change occurs in the liquid, the sensor detects it and sends an anomaly signal to the control device. 【Three Types of Barrier Systems】 ○ BC1: Standard Barrier System (with sensor) ○ BC2: Barrier System (with sensor and control device) ○ BC3: Barrier System (with sensor and control device) for explosion-proof use - ATEX For more details, please contact us or download the catalog.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe "Metal Diaphragm Pump (Special Material Pump)" includes aluminum pumps with PTFE coating, cast iron pumps with PE conductive coating (conductive polyethylene) on the center section, metal pumps with integrated heaters and cooling jackets, and pumps with optional handles for drum pump use. 【Features of Aluminum Pumps with PTFE Coating】 ○ Suitable for fluids similar to those used in AISI316 pumps ○ Pump connections are made of AISI316 ○ Ideal for the printing industry and ink manufacturing industry For more details, please contact us or download the catalog.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe "Helix V Series" is an inline vertical multistage pump without priming, available in two types (16bar and 25bar). The impeller, diffuser, and pump casing are made of stainless steel 304 or optionally 316L. The motor shaft and pump shaft conform to IEC standards and are assembled with a flexible coupling, additionally reinforced with large bearings to support thrust loads (over 7.5kW). 【Features】 ○ The flanges for V1 type and V18 type allow for motor replacement → Uses a bidirectional cartridge mechanical seal for maintenance and repair ○ All materials are suitable for drinking water → Certified by Germany's KTW and the UK's WRC For more details, please contact us or download the catalog.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationWe would like to introduce our lineup of equipment for sanitary processes (drum pumps/diaphragm pumps). We offer products suitable for sanitary processes, including a centrifugal drum pump with a maximum flow rate of 35 GPM (132 LPM), as well as diaphragm pumps that have obtained 3A certification and are FDA compliant. 【Lineup of Equipment for Sanitary Processes】 ○ Drum Pump - Centrifugal ○ Drum Pump - Single-Screw ○ Diaphragm Pump - 3A Certified ○ Diaphragm Pump - FDA Compliant, and more For more details, please contact us or download the catalog.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationNewIsomon-2 can measure hydrogen peroxide gas over a wide range with a single unit. For example, it can measure high concentration levels (0-2000ppm) during the sterilization process of hydrogen peroxide gas in pharmaceutical and food factories, as well as low concentration levels (0-100ppm) after aeration, all with one device. 【Features】 - It has a built-in suction pump, allowing for quick concentration measurements. - It comes standard with a 4-20mA output and alarm output necessary for control. - It can measure concentrations within the range of 0-2000ppm with high precision. *Demo units are available. Please feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe Q46H/62-63 residual chlorine meter adopts a polarographic membrane sensor, allowing for the direct measurement of free chlorine, active chlorine, and combined chlorine (monochloramine) without the need for reagents. Due to its diaphragm-type sensor, it is less affected by changes in the measurement liquid or impurities, enabling the measurement of residual chlorine in electrolyzed hypochlorous water, seawater, wastewater, hot springs, and pure water. Additionally, since the electrode does not come into direct contact with the measurement liquid, it is less prone to contamination and has a long lifespan. By adding a pH sensor option, simultaneous measurement of chlorine and pH is possible. The pH correction function allows for measurements even when the pH value is high or fluctuating. It has a wide measurement range, capable of measuring low concentrations below 1 mg/L and high concentrations above 100 mg/L with a single unit. 【Features】 ■ No reagents required ■ Easy installation ■ Wide and flexible measurement range ■ Cost-effective *Demo units are available, so please feel free to inquire. *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe "Q46H/79PR type" is a total chlorine meter that allows for inline continuous measurement without reagents. It is suitable for managing effective chlorine (free chlorine and combined chlorine) after chloramine treatment and disinfection. Additionally, it can be used in seawater or low conductivity environments without the need for chemical reagent additions. Furthermore, options for pH measurement and additional outputs are available. 【Features】 ■ Inline continuous measurement without reagents ■ No need for chemical reagent additions ■ Usable in seawater and low conductivity environments ■ Options for pH measurement and additional outputs available *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe Q46H/79S total chlorine meter is resistant to interference from contaminants and can measure total chlorine concentration with high precision. It features a unique structure that prevents contact between the measurement liquid and the sensor, and it has a proven track record in special applications worldwide, such as drinking water, wastewater, and cooling towers. 【Features】 - High precision - Capable of handling a wide range of applications - Measures by gasifying the sample liquid
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe "Q46H/65" is a chlorine dioxide meter suitable for disinfection and sterilization systems, as it can continuously produce chlorine dioxide water. Being a diaphragm type, it can operate in environments with low conductivity and many impurities. Additionally, it has multiple outputs, including 4-20mA analog output, PID control, and digital communication, making it applicable for measuring any chlorine dioxide water. 【Features】 ■ Displays chlorine dioxide and pH on the indicator ■ Remote monitoring and recording capabilities ■ Ideal for disinfection and sterilization systems ■ Diaphragm type, suitable for environments with low conductivity and many impurities ■ Applicable for measuring any chlorine dioxide water *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThis product is a gas detector that can measure gas concentrations in the air with simple operations. It can be used with one hand, and with the built-in suction pump and sampling wand, it is possible to pinpoint the location of gas leaks. Additionally, the sensor module can be easily replaced, allowing one unit to measure multiple gases. 【Features】 ■ Can pinpoint the location of gas leaks ■ Capable of measuring multiple gases with one unit ■ Sensor module can be easily replaced ■ Large LCD display with backlight for clear visibility in dark places ■ Equipped with an alarm that sounds and lights up when the measured value reaches the set value *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe "F12 model" is a hydrogen peroxide concentration meter for safety management and concentration management. It can measure high concentration ranges (0-2000ppm) used in sterilization processes and low concentration ranges (0-100ppm) to check residual concentrations after aeration. Additionally, it has a strong track record with major pharmaceutical companies, allowing for measurements that are close to theoretical values due to calibration with actual gas. 【Features】 ■ Strong track record with major pharmaceutical companies ■ Capable of measuring values close to theoretical values due to calibration with actual gas *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe "F12 model" is a peracetic acid gas concentration meter. It is a fixed installation type, and with various measurement ranges and options available, it can accommodate a wide range of specifications. In addition to this product, we also offer a rich selection of sensors for hydrogen peroxide, peracetic acid, chlorine dioxide, ozone, EOG gas, and more. 【Sensor Selection Table】 ■ Measured Gas: Peracetic Acid / Peracetic Acid / Acetic Acid ■ Sensor Model: 00-1704 / 00-1705 / 00-1045 ■ Minimum Range: 0-1ppm / 0-10ppm / 0-100ppm ■ Maximum Range: 0-5ppm / 0-100ppm / 0-500ppm ■ Standard: 2ppm / 20ppm / 100ppm *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe "F12 model" is an ozone gas concentration meter. The gas detectors from ATI that we handle can measure over 30 types of toxic gases and oxygen. They are used in various locations such as plants and laboratories. Additionally, we also offer "EOG gas concentration meters," "chlorine dioxide gas concentration meters," and "formaldehyde gas concentration meters." 【Sensor Selection Table】 ■ Measured Gas: Ozone ■ Sensor Model: 00-1163 / 00-1008 / 00-1009 / 00-1358 ■ Minimum Range: 0–500 ppb / 0–1 ppm / 0–5 ppm / 0–200 ppm ■ Maximum Range: 0–2000 ppb / 0–5 ppm / 0–200 ppm / 0–1000 ppm ■ Standard: 0–1000 ppb / 2 ppm / 20 ppm / 1000 ppm ■ Auto Test Generator: 00-1538 * For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe "F12 type" is a chlorine dioxide gas concentration meter. The gas detectors from ATI that we handle can measure over 30 types of toxic gases and oxygen. They are used in various locations such as plants and laboratories. Additionally, we also offer "EOG gas concentration meters," "ozone gas concentration meters," and "formaldehyde gas concentration meters." 【Sensor Selection Table】 ■ Measured Gas: Chlorine Dioxide ■ Sensor Model: 00-1004 / 00-1005 / 00-1359 / 00-1425 ■ Minimum Range: 0-1ppm / 0-5ppm / 0-200ppm / 0-1ppm ■ Maximum Range: 0-5ppm / 0-200ppm / 0-1000ppm / 0-5ppm ■ Standard: 2ppm / 20ppm / 200ppm / 5ppm ■ Auto Test Generator: 00-1538 / 00-1538 / - / 00-1538 *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe "F12 model" is a formaldehyde gas concentration meter. The gas detectors from ATI that we handle can measure over 30 types of toxic gases and oxygen. They are used in various locations such as plants and laboratories. Additionally, we also offer "EOG gas concentration meters," "ozone gas concentration meters," and "chlorine dioxide gas concentration meters." 【Sensor Selection Table】 ■ Measured Gas: Formaldehyde ■ Sensor Model: 00-1040 / 00-1349 ■ Minimum Range: 0-20 ppm / 0-500 ppm ■ Maximum Range: 0-200 ppm / 0-2000 ppm ■ Standard: 20 ppm / 1000 ppm ■ Auto Test Generator: 00-1539 *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe "F12 model" is an EOG gas concentration meter. The gas detectors from ATI that we handle can measure over 30 types of toxic gases and oxygen. They are used in various locations such as plants and laboratories. Additionally, we also offer "ozone gas concentration meters," "chlorine dioxide gas concentration meters," and "formaldehyde gas concentration meters." 【Sensor Selection Table】 ■ Measured Gas: Ethylene Oxide ■ Sensor Model: 00-1039 ■ Minimum Range: 0–20 ppm ■ Maximum Range: 0–200 ppm ■ Standard: 20 ppm ■ Auto Test Generator: 00-1539 *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationIt supports the detection of over 30 types of gases, including hydrogen fluoride, ozone, and chlorine. By simply attaching the target gas sensor module to the gas detector, you can detect low-concentration gas leaks and measure high-concentration gas levels. 【Features】 ■ Easy to replace due to the use of smart sensors, eliminating the need for on-site calibration. ■ Intrinsically safe explosion-proof structure (ATEX, IECEx) - Is type only ■ Large and easy-to-read LCD display *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe "Q46F model" can be used for continuous measurement of fluoride ions in wastewater, effluent, and drinking water. It employs a fluoride ion selective electrode (ISE) and can measure fluoride ions from 0.1 PPM to a maximum of 1000 PPM. With its simple structure, it allows for low-cost continuous measurement of fluoride ions. *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe dissolved ammonia meter "Q46N" can continuously measure the ammonia concentration in water. Compared to traditional complex systems, it is inexpensive, easy to operate, and a highly reliable online ammonia measuring device. By adding a monochloramine sensor as an option, it can measure trace amounts of ammonia nitrogen. It has a proven track record in chloramine treatment, drinking water, and water quality management in lakes, rivers, and seas. *Demo units are available, so please feel free to contact us.* 【Features】 ■ Demo units available ■ Inexpensive and easy to operate ■ Capable of measuring trace amounts of ammonia nitrogen (optional feature available) *For more details, please refer to the PDF document or feel free to contact us.*
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe "Q46S/66 model" is a measuring device that can measure residual sulfite ions and reduce the consumption of chemicals that are being used excessively. This product allows for the measurement of sample water without contact between the sensor and the fluid, enabling the removal of wastewater for measurement. A small amount of residual sulfite ions during dechlorination treatment is effective for complete dechlorination, and measuring the concentration of residues can control the chemical dosing, significantly reducing chemical costs. 【Features】 ■ Selectively converts sulfite ions to sulfur dioxide (sulfurous gas) for measurement ■ Sample water and sensor do not come into contact with the fluid, allowing for the removal of wastewater for measurement ■ Power supply can be selected as 115 or 230 VAC, 60/60 Hz ■ Maintains stable costs for chemicals ■ Controls chemical dosing through the measurement of residue concentration, significantly reducing chemical costs ■ Allows for savings on chemicals *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe "Q46H/64 type" dissolved ozone meter can continuously measure dissolved ozone in water without the need for reagents. It employs a diaphragm-type polarographic sensor, which means the electrode does not come into direct contact with the measuring liquid. As a result, it is less affected by impurities and can be used for measurements in wastewater. The electrode is resistant to contamination, ensuring a long lifespan and cost-effective usage. Additionally, it can handle a wide range of concentrations, from low levels below 100 ppb to high levels above 100 ppm. 【Features】 ■ Strong resistance to contamination achieved through the diaphragm-type polarographic sensor that protects the electrode ■ No adjustment needed after sensor replacement ■ Large LCD display ■ Optional wide-range measurement from 0 to 200 PPB to 0 to 200 PPM ■ Standard PID control function can be assigned to analog output *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe "Q4Q46/88 model" is an SS meter that can measure and monitor particles in various water and wastewater in real-time. Measurements can be taken by inserting an immersion-type sensor into the process tank, or for a wide range of measurements, a sensor using optical backscatter technology is employed. The measurement results are displayed on the Q46 electronic unit located near the sensor. 【Specifications】 ■ Measurement target: SS concentration ■ Measurement range: 0-100.0 / 0-1000 mg/l, 0-10.00 g/l ■ Sensor type: Flow-through type ■ Equipped with automatic air cleaning function *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe turbidity meter "Q46 / 76 model" offers precision and reliability for low-range turbidity measurements and is widely used around the world. It is designed to be suitable for drinking water systems and industrial water treatment. 【Features】 ■ High precision low-range turbidity measurement ■ Proven track record worldwide ■ Optional features available *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe Q46D dissolved oxygen meter is an ideal measurement control device that can maintain reliability for monitoring measurements throughout the entire year by utilizing an automatic cleaning function. It has a proven track record in biological processes at wastewater treatment plants.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe Q46/84 type hydrogen peroxide meter is designed to continuously measure H2O2 in aqueous solutions. Hydrogen peroxide is used for disinfection, odor control, oxygen treatment, and various controls such as cyanide oxidation, and measuring it allows for efficient control. *We also have demo units available, so please feel free to contact us.*
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe Q46/85 peracetic acid meter features a diaphragm-type sensor, making it resistant to interfering substances and capable of handling water quality with low conductivity. It is used for cleaning pipes in the food industry, disinfecting peracetic acid (PAA) production equipment, washing food, and disinfecting cooling water systems. It is a reliable measuring instrument for online real-time measurement of peracetic acid (PAA). Additionally, it is not affected by changes in the concentration of hydrogen peroxide present in the solution.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe Q46P/R type pH/ORP meter is a highly accurate, reliable, and versatile measuring instrument. It is used for the routine monitoring of pH values in various liquid processing systems, including water supply and drainage, wastewater, cooling water, pure water, cleaning water in food manufacturing processes, and cooling water in chemical plants, among many others.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe Q46C2 conductivity meter is a highly precise and reliable measuring instrument for measuring the high purity water required in pure water systems. It features a large, easy-to-read LED display, and the sub-display can show temperature and other information. Since it may be appropriate to display values in resistivity units, the Q46C2 conductivity meter allows for the measurement unit to be changed.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe ATI Q46C4 type 4-electrode conductivity meter is a water quality meter that meets the conductivity measurement needs of most liquids. It has a proven track record in drinking water, cooling water, chemical solutions, and other water treatment systems.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe A14/A11 series is a gas detector that can add various functions with just one unit. Since the functions can be customized, it is adopted by major pharmaceutical factories, semiconductor manufacturing plants, and research laboratories in Japan. It can be used for both simple and complex applications, making it suitable for indoor gas detection, safety management systems, and more! 【Features】 ■ Capable of measuring up to 12 locations ■ Sensor cables can be extended up to 300m ■ Usable for both simple and complex applications
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationIt is a device for removing moisture from gas that contains moisture. It can also be used with ATI gas detectors and gas detectors from other manufacturers.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationGenerating approximately 0.8 ppm of ozone gas at about 500 cc/min.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe 2-wire transmitter (wet gas detector) can measure the concentration of wet gases. We have a proven track record of confirming removal after scrubber treatment. Measurable gases: Chlorine, chlorine dioxide, bromine, ozone, hydrogen fluoride, hydrogen chloride, hydrogen 【Features】 ■ Cost-effective and easy to handle ■ Capable of detecting a variety of gases *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe A12-17 type combustible gas detector can reliably measure combustible gases. An automatic testing function can be added as an option, allowing for a reduction in labor costs.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe "Batch Control System for Drum Pumps / Electric Motor Type (for Low Viscosity)" features a clear LCD display and allows for easy setting and calibration with just button operations. It employs a highly accurate paddle wheel flow meter, making it ideal for small packaging and semi-automated applications. Available in PP, PVDF, and SUS models, it can handle various fluids. It supports the setting and saving of up to 10 different liquids. Additionally, it comes with a remote start function. 【Features】 ■ Three-color backlight display ■ Pulse output relay ■ Multilingual functionality ■ Chemical resistance ■ Easy operation *For more details, please refer to the catalog. Feel free to contact us with any inquiries.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe "SP-48WD" is a lightweight and easily movable pump lifter, ideal for the food processing sector. It comes with a rechargeable battery pack and a detachable hand controller. Additionally, it features a foot-operated brake. 【Features】 ■ Perfect for food processing environments ■ Lightweight and portable ■ Rechargeable battery pack ■ Detachable hand controller ■ Foot-operated brake *For more details, please refer to the catalog. Feel free to contact us with any inquiries.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationBy measuring the turbidity during the stirring and backwashing of the accumulated material at the bottom of the tank, optimal filter cleaning can be achieved.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationWe handle ATI's "Dissolved Ozone Meter" and "D16 Portable Gas Detector," which allow for easy and reliable measurement of ozone concentration. They have a wide measurement range, excellent operability, and visibility of displays, making them widely adopted across various industries. 【Features】 "Dissolved Ozone Meter Q46H/64 Model" - Compatible with ProfibusDP, Modbus, and Ethernet - Supports two separate 4-20mA analog outputs - pH measurement monitoring is also possible - Large LCD display with backlight - Standard equipped with three SPDT relays "D16 Portable Gas Detector" - Usable with one hand - Large LCD allows for confirmation of ozone concentration and alarm messages even in dark places - Powered by D-cell alkaline batteries and rechargeable batteries - Equipped with data logger functionality, manageable via computer - Offers more than 30 sensor modules, not just for ozone *We also handle spare parts for the old model (C16). *For more details, please refer to the materials. Feel free to contact us with any inquiries.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThis pump is ideal for the transfer of corrosive chemical fluids and viscous fluids. The housing is made of homogeneous PE and PTFE. A notable feature is that the screw connection can rotate 180 degrees. 【Main Features】 ■ Optimal design values ■ Flexible mounting methods ■ Homogeneous and robust structure ■ Highest quality diaphragm For more details, please refer to the catalog or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationWe have a system that automatically performs cleaning and disinfection for CIP (Clean-in-Place) and SIP (Sterilization-in-Place) without the need to disassemble and reassemble the pump. It features a clamp design that allows for quick removal without tools. The wetted parts and external finish are made of sanitary electropolished stainless steel (SUS). The diaphragm is made of high-purity TFM (PTFE) material suitable for food grade applications. 【Main Features】 ■ Easy to remove ■ Smooth surface ■ Highest level of finishing ■ Clean air valve ■ Diverse connection types ■ Pump designed for CIP and SIP systems For more details, please refer to the catalog or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe "SP8600 model / SP8700 model" is a sanitary pump designed for hygiene and sterilization, manufactured with materials and structures that meet FDA standards. It is ideal for transferring various fluids such as juice, concentrated liquids, beer, wine, and cosmetic liquids from various containers and tote tanks. 【Structural Features】 ■ Easy to clean ■ Tri-clamp fittings ■ Lightweight and portable ■ Variable speed electric motor and air motor ■ Dry running For more details, please refer to the catalog or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe standard polypropylene pump tube is designed for the transfer of a wide range of corrosive fluids and is ideal for transferring stimulating chemical fluids due to its robust polypropylene material. 【Applicable Fluids】 ■ Acetic acid ■ Nitric acid ■ Sulfuric acid ■ Alkali ■ Hydrochloric acid ■ Ferric chloride, etc. *The above are representative examples. Other fluids can also be measured. We can provide a demonstration. Please feel free to consult us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe STANDARD Pump Company's "Chemical Drum Pump for Water Treatment" is a high-quality and safe drum pump. Additionally, it is possible to purchase only the tubes or parts, and it has been highly regarded for its maintenance service. 【Features】 ○ Ideal for the transfer of chemicals and solutions associated with industrial water treatment ○ Applicable fluids → Sodium hypochlorite / Sodium hypochlorite solution → Calcium chloride → Potassium hydroxide → Potassium hydroxide (caustic potash) → Fluids containing sodium bromide → Chlorination treatment (disinfectants, neutralizers, hand sanitizers) *The above are representative examples. Other fluids can also be measured. We can provide a demonstration. Please feel free to consult us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThis pump adopts a flap valve type. Therefore, it can transport solid materials such as 62.5mm. It is made of SUS316 material, and the inlet/outlet is connected with a hygienic fitting, allowing for quick disassembly and assembly for maintenance and cleaning. Size: 3.0S Maximum temperature: 82.2℃ Maximum particle size: 62.5mm For more details, please contact us or download the catalog.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe standard stainless steel pump tube is designed for the transfer of diesel fuel and similarly flammable chemical fluids, featuring excellent strength and reliability with robust 316 stainless steel. 【Applicable Fluids】 ■ Alcohol ■ Various solvents ■ Isopropyl ether ■ Aqueous ammonia ■ Gasoline ■ Petroleum-based fluids, etc. *The above are representative examples. Other fluids can also be measured. We can provide a demonstration. Please feel free to consult us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration