"UNICUBE" is an organic elemental analysis device for trace samples that combines high scalability and robustness. The analysis time is within 10 minutes. With a durable electric furnace capable of reaching up to 1200°C and sampling technology that can reach 1800°C, it enables the analysis of difficult samples that are challenging for other companies. Additionally, the unique gas separation technology of Elementar, which is significantly different from conventional GC methods, provides a unique dynamic range, detection limits, and repeatability for the analysis of CHNS+O (with *Cl as an option). 【Features】 ■ Achieves 2 ppm (sulfur) with NDIR option ■ Enables ultra-low concentration nitrogen analysis ■ Complies with 21 CFR Part 11 ■ Body width of only 48 cm *For more details, please refer to the PDF document or feel free to contact us. *When requesting a quote, demo, or sample measurement, please mention that you saw this in the Ipros newsletter. A special Elementar Japan original mug (manufactured by Zojirushi) will be presented. Other model selections are also possible (until February 28, 2025).
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration
UNICUBE is an organic element analysis device for trace samples that combines high scalability and robustness. Its high gas separation performance, based on our proprietary temperature-programmed desorption technology (Direct TPD), provides reliable measurement results. It is capable of measuring samples with an elemental ratio of up to 12,000:1 (C:N ratio / C:S ratio). <Features> ● From high-purity chemicals of 0.1 mg to heterogeneous soils of 1 g ● Capable of measuring up to 6 elements (C, H, N, S, O, Cl: O and Cl are optional) ● Maintenance without tools ● Standard equipped with an auto-sampler (for 120 samples) ● Blank-free ball valve (patented technology) ● Multi-language support, including Japanese display
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration
Organic Elemental Analyzer vario EL cube A versatile type capable of measuring from trace to semi-macro samples. Unmatched performance condensed from over 125 years of experience and expertise. This device can measure all types of samples, from trace high-purity chemicals to 1g soil samples, with just one unit. Selective adsorption: The APT method uses three types of adsorption-desorption columns that selectively adsorb CO2 from carbon, H2O from hydrogen, and SO2 from sulfur. Nitrogen detection: Nitrogen-derived NOx is reduced to N2 gas and is detected first without being adsorbed by the column. High adsorption capacity: The adsorption-desorption columns can achieve up to 250 times the adsorption capacity of typical GC columns, allowing for the analysis of samples containing up to 500mg of carbon. Sharp detection peaks: Rapid heating of the column results in sharp detection peaks, achieving an excellent S/N ratio. Complete peak separation: Each component's heating and desorption can be fully controlled, allowing for complete peak separation regardless of elemental content or ratios. The C/N and C/S ratios can be accurately separated and analyzed up to a maximum of 12,000:1.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration
The vario MAX cube is an automatic analyzer for carbon, nitrogen, and sulfur, equipped with an automatic ash recovery function. It handles large sample sizes of 5 g / 5 ml and excels with heterogeneous samples. Even with soil samples that contain a lot of inorganic components, continuous unmanned operation can be performed without worrying about interruptions in measurement due to the automatic ash recovery function. It is the perfect device for labs that require high-throughput analysis. <Features> ● Uses a robust, tall stainless steel crucible for easy sampling ● High analytical precision and large capacity measurement achieved with a "post-combustion tube" suitable for heterogeneous samples ● Selectable carrier gas (helium or argon) ● Convenient automatic ash recovery for samples with a lot of inorganic components ● Options for total organic carbon and total carbon measurement available ● Multi-language support, including Japanese display
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration
Organic Elemental Analyzer vario MACRO cube The only device capable of simultaneous analysis of carbon, hydrogen, nitrogen, and sulfur with large capacity samples. No additional modules or electric furnaces for sulfur analysis, like other devices, are required. High precision measurements can be achieved even with heterogeneous large capacity samples. <Features> 1. Selective adsorption: The APT method uses three types of adsorption-desorption columns that selectively adsorb CO2 from carbon, H2O from hydrogen, and SO2 from sulfur. 2. Nitrogen detection: Nitrogen-derived NOx is reduced to N2 gas and is detected first without being adsorbed by the column. 3. High adsorption capacity: The adsorption-desorption columns can achieve up to 250 times the adsorption capacity of typical GC columns, allowing analysis of samples containing up to 500 mg of carbon. 4. Sharp detection peaks: Rapid heating of the column results in sharp detection peaks, achieving an excellent S/N ratio. 5. Complete peak separation: Complete control over the heating and desorption of each component allows for complete peak separation regardless of elemental content or ratio. The C/N ratio and C/S ratio can be accurately separated and analyzed up to 12,000:1.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration
The inductar CS cube is a new carbon and sulfur analysis device that is highly accurate, user-friendly, resistant to dirt, fully automated, and equipped with everything required. It gathers innovations and creative ideas that enable unprecedented ease of use and reliability, changing the concept of CS analysis. <Features> ● Dirt-resistant internal structure and easy maintenance ● Standard equipped with an auto-sampler (89 holes or semi-auto) ● Long-lasting solid-state high-frequency induction heating furnace ● Grip-type piping connection (easy maintenance without tools) ● Highly functional software that is intuitive to use ● High-precision analysis of sulfur in steel ● Multi-language support, including Japanese display
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration
The Soli TOC cube is a groundbreaking device that enables automatic separation and quantification of total organic carbon (TOC), total inorganic carbon (TIC), and elemental carbon (ROC) without the need for acid treatment. It features easy sampling with a unique crucible and allows fully automated separation measurements of different carbon species through multi-stage temperature increases. <Features> ■ Challenges in TOC measurement: Simply distinguishing TIC is insufficient, as the presence of ROC has an impact. ■ Importance of ROC: Measuring ROC allows for accurate TOC measurement. ■ Multi-stage temperature method: TOC, ROC, and TIC are measured at 400°C, 600°C, and 900°C, respectively. ■ Carrier gas switching: After exceeding 400°C, switch from oxygen to nitrogen and perform pyrolysis at 900°C. ■ Measurement process: After TIC measurement, return the carrier gas to oxygen to oxidize and detect ROC. An effective method for measuring many samples.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration
The fully organic carbon analysis device vario TOC cube features: 1. Diverse measurement parameters and sample compatibility It can measure TOC, NPOC, TC, TIC, DOC, POC, and TNb, accommodating a wide range of sample types including pure water, industrial wastewater, high-concentration saltwater, and solids. It is also suitable for difficult-to-decompose compounds, ensuring accurate analysis. 2. Flexible customization It supports automatic/manual sample introduction, liquid/solid sample compatibility, and can perform TOC-only measurements or simultaneous TOC and TNb measurements, catering to various user requests. Additionally, optional units allow for the analysis of TIC in solids. 3. Excellent measurement accuracy It maintains stable accuracy over a wide range from several ppb to several percent, providing high reliability even in the analysis of solid samples. 4. Efficient routine analysis With easy maintenance and the capability for unmanned operation through an auto-sampler, it offers options for 32, 50, or 80 sample capacity, enhancing the efficiency of daily operations. 5. Low running costs with SALTTRAP By employing SALTTRAP to prevent component deterioration due to salt crystallization, it extends the lifespan of parts and reduces running costs. Its unique technology enables high-sensitivity continuous analysis without the need for maintenance.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration
Elementar's TOC analysis device has been highly regarded in the field of environmental water analysis and wastewater analysis around the world for decades. As a result of further innovations, the enviro TOC has finally been born, packed with new technologies such as a powerful electric furnace, easy measurement mode switching, the desalination technology SALTTRAP, and a highly stable wide-range non-dispersive infrared detector (NDIR). In addition to the new auto-sampler, TNb measurement using a chemiluminescence detector (CLD) is also possible. In measuring TOC and TN contained in environmental water and wastewater, the enviro TOC is an ideal and futuristic device that enables flexible and efficient analysis. <Features> ● Standard equipped with an auto-sampler (60 holes / 40 ml EPA vials) ● Easy maintenance desalination technology SALT TRAP even for high salt concentration samples ● Combustion temperature that does not select samples, up to 1200℃ ● High versatility with rapid liquid/solid mode switching (solid option) ● Automatic cleaning function to suppress contamination and protect the injection unit
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration
The visION series is a stable isotope ratio analysis solution that includes an elemental analyzer (EA) and a gas chromatograph (GC) as pretreatment devices for the stable isotope ratio mass spectrometer (IRMS). We propose optimal solutions for various applications, including food analysis, fragrance analysis, earth sciences, and archaeology. 1. A stable isotope analysis solution that prioritizes ease of use. 2. Standardized workflows through automated and simplified operations, ensuring data quality independent of the operator. 3. Complete software control that is less affected by the operator's skill level. 4. Reduction of implementation costs for systems specialized in routine analysis by refining unnecessary functions. 5. One general-purpose pretreatment device included, with the capability to connect one additional type, for a maximum of two types of pretreatment devices.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration
• Incredible new capabilities for acquisition and data processing. • Elegant user interface with contextual control. • Intelligent and automatic instrument performance optimization. • Instantaneous data processing with dynamically updating results. • Import your data from 3rd party instruments.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration