1~40 item / All 40 items
Displayed results
Filter by category
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration
Contact this company
Inquiry Form1~40 item / All 40 items
Filter by category

Do you have any of these concerns? - Preventing theft of offering boxes - This is ● Shrine. The sensor has detected something. The reporting device (WhiteLock) fundamentally solves these issues. ◇ An infrared sensor is installed on top of the offering box to detect suspicious individuals at night and report them. ◇ By wiring the alarm signal from the infrared sensor to the reporting device (WhiteLock), it will notify you when the sensor detects something. *For more details, please refer to the materials available for download from <Download Catalog>. Feel free to contact us as well.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration
Do you have any of these concerns? - Remote monitoring of temperature abnormalities in refrigeration and freezing units - This is freezer A. A high-temperature alarm has been triggered. The notification device (WhiteLock) fundamentally solves these issues. ◇ By simply wiring alarm signals (temperature, humidity, power outage, malfunction) from the refrigeration and freezing units to the notification device (WhiteLock), you can monitor the temperature of food and pharmaceuticals that require a constant temperature 24 hours a day. *For more details, please refer to the materials available for download from <Download Catalog>. Feel free to contact us with any inquiries.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration
Do you have any of these concerns? - Prevention of intruders, theft, and fire in nighttime warehouses and unmanned warehouses The reporting device (WhiteLock) fundamentally solves these issues. ◇ By wiring infrared sensors installed in nighttime warehouses or unmanned warehouses, and magnet-type door sensors attached to doors, as well as alarm signals from fire detectors to the reporting device (WhiteLock), it will notify you when the sensors detect something. *For more details, please refer to the materials available for download in the catalog. Feel free to contact us with any inquiries.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration
Do you have any of these concerns? - Preventing vandalism of vending machines at night - This is a vending machine. The vibration sensor has detected something. The reporting device (WhiteLock) fundamentally solves these issues. ◇ By wiring alarm signals from vibration sensors and impact sensors to the reporting device (WhiteLock), it will notify you when the sensors detect something. *For more details, please refer to the materials available for download in the catalog. Feel free to contact us as well.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration
Do you have any of these concerns? - Prevention of intrusions and fires at vacation homes or stores - This is a vacation home. An intruder has been detected. The reporting device (WhiteLock) fundamentally solves these issues. ◇ By wiring the alarm signals from infrared sensors installed in vacation homes or stores, magnet-type door sensors attached to doors, and fire alarms to the reporting device (WhiteLock), it will notify you when the sensors detect something. *For more details, please refer to the materials available for download from <Download Catalog>. Feel free to contact us with any inquiries.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration
Do you have any of these concerns? - Wind power generation is often susceptible to lightning strikes, which can lead to blade damage and fire accidents. - From the perspective of ensuring public safety, it is important to install lightning detection devices on wind turbine equipment. The reporting device (WhiteLock) fundamentally resolves these issues. ◇ By simply wiring the alarm signals from the lightning detection device to the reporting device (WhiteLock), you can remotely monitor wind power generation 24 hours a day, 365 days a year. *For more details, please refer to the materials available for download from <Download Catalog>. Feel free to contact us with any inquiries.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration
Do you have any of these concerns? - Remote monitoring of the kerosene boiler (oil water heater) for fuel level and malfunctions. - This is Boiler A. The fuel level is low. The reporting device (WhiteLock) fundamentally solves these issues. ◇ By simply wiring alarm signals (fuel level, malfunctions) from the kerosene boiler (oil water heater) and sensors to the reporting device (WhiteLock), you can monitor the boiler's status 24 hours a day, 365 days a year. ◇ Alarm signals can also be transmitted using low-power radio to locations with telephone lines. *For more details, please refer to the materials available for download from <Download Catalog>. Feel free to contact us with any inquiries.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration
Do you have any of these concerns? - Solar power generation is not maintenance-free. - This is Solar Power Plant A. A power outage has occurred. The reporting device (WhiteLock) fundamentally solves these issues. ◇ By simply performing the necessary wiring from the power conditioner with a voltage-free contact to the reporting device, remote monitoring is possible 24 hours a day. ◇ Additionally, when a power outage occurs in an area that includes solar power generation, operations will stop. ◇ Power outage notifications are also possible, so early resumption of operations can be expected. * For more details, please refer to the materials available for download in the <Download Catalog>. Feel free to contact us with any inquiries.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration
Do you have any of these concerns? - Responding to the opening and closing of sluice gates and weirs - This is Sluice Gate A. The water level has risen. The reporting device (WhiteLock) fundamentally solves these issues. ◇ By simply wiring the signal from the water level sensor to the reporting device (WhiteLock), you can remotely monitor the river's water level 24/7, 365 days a year. ◇ Alarm signals can also be transmitted to locations with telephone lines using specific low-power radio. *For more details, please refer to the materials available for download in the catalog. Feel free to contact us as well.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration
Do you have any of these concerns? - When the motor pump (blower) stops operating, the air supply to the tank ceases, putting the farmed fish in a state of oxygen deprivation. - If this condition persists for a certain period, the farmed fish will die. - Additionally, immediate action is required in the event of a malfunction of the cold water chiller (cold water circulation device) or hot water chiller (hot water circulation device) that controls water temperature. The reporting device (WhiteLock) fundamentally solves these issues. ◇ By simply wiring alarm signals from water level gauges, dissolved oxygen concentration meters, blowers, and circulation devices to the reporting device (WhiteLock), remote monitoring of the tank can be achieved 24 hours a day, 365 days a year. ◇ Alarm signals can also be transmitted using low-power radio to locations with telephone lines. *For more details, please refer to the materials available for download from <Download Catalog>. Feel free to contact us with any inquiries.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration
Do you have any of these concerns? - Remote monitoring of temperature, humidity, and water leaks in food factories and warehouses - This is Warehouse A. A temperature alarm has been triggered. The notification device (WhiteLock) fundamentally solves these issues. ◇ By simply wiring alarm signals (temperature, humidity, water leaks, flooding, power outages) from various sensors in food factories and warehouses to the notification device (WhiteLock), you can monitor remotely 24 hours a day, 365 days a year. ◇ Alarm signals can also be transmitted using low-power radio to locations with telephone lines. *For more details, please refer to the materials available for download in the catalog. Feel free to contact us with any inquiries.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration
Do you have any of these concerns? - Security against intruders, theft, and fire for women living alone - This is your home. An intruder has been detected. The reporting device (WhiteLock) fundamentally solves these issues. ◇ By wiring infrared sensors, magnet-type door sensors installed on windows, and alarm signals from smoke detectors to the reporting device (WhiteLock), it will notify you when the sensors detect something. *For more details, please check the materials by downloading the catalog. Feel free to contact us as well.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration
Do you have any of these concerns? - If water exceeding discharge standards is released, the decline in corporate trust due to environmental pollution and health damage is a significant issue. - This is Factory A. A pH anomaly has occurred. The reporting device (WhiteLock) fundamentally resolves these challenges. ◇ By simply wiring the alarm signals output from each sensor (pH, turbidity, water level) and equipment (such as pumps) to the reporting device (WhiteLock), water quality can be monitored remotely 24/7, 365 days a year. ◇ The alarm signals can also be transmitted using low-power radio to any location with a telephone line. *For more details, please refer to the materials available for download from <Download Catalog>. Feel free to contact us with any inquiries.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration
Do you have any of these concerns? - Early response is necessary for equipment failures or stoppages during unmanned nights and holidays. - This is Factory A. A failure alarm has been triggered. The reporting device (WhiteLock) fundamentally solves these issues. ◇ By simply wiring alarm signals (failure, power outage) from equipment to the reporting device (WhiteLock), you can monitor the equipment 24/7, 365 days a year. ◇ Alarm signals can also be transmitted using low-power radio to locations with telephone lines. *For more details, please refer to the materials available for download in the catalog. Feel free to contact us with any inquiries.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration
Do you have any of these concerns? - Preventing theft at construction sites and material storage areas - This is the ●● material storage area. An intruder has been detected. The reporting device (WhiteLock) fundamentally solves these issues. ◇ By wiring the alarm signal from the photoelectric sensor (beam sensor) to the reporting device (WhiteLock), it will report when the sensor detects something. ◇ The alarm signal can also be transmitted using low-power radio to locations with telephone lines. *For more details, please refer to the materials available for download in the catalog. Feel free to contact us with any inquiries.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration
Do you have any of these concerns? - Managing temperature and humidity requires monitoring equipment such as ventilation fans and heating devices. - Temperature sensors, power outages, and ventilation fan failure alarm signals are received and reported by WhiteLock (the reporting device). The reporting device (WhiteLock) fundamentally resolves these issues. ◇ By simply wiring alarm signals (temperature, humidity, ventilation fan and other equipment failures, power outages) from within the livestock barn to the reporting device (WhiteLock), you can remotely monitor environmental conditions 24 hours a day, 365 days a year. ◇ Alarm signals can also be transmitted using low-power radio to locations with telephone lines. *For more details, please refer to the materials available for download in the catalog. Feel free to contact us with any inquiries.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration
Do you have any of these concerns? - To ensure the safety of pedestrians, during strong winds, pedestrian and bicycle traffic will be halted for 10 minutes at an average wind speed of 10-15 m/s, and completely stopped at 15-25 m/s. - To prevent falls, it is important to take measures such as alerting pedestrians on-site. The reporting device (WhiteLock) fundamentally solves these issues. ◇ By simply wiring the alarm signals from the anemometer to the reporting device (WhiteLock), you can remotely monitor wind speeds on the bridge 24 hours a day, 365 days a year. ◇ The alarm signals can be transmitted using specific low-power radio to any location with a telephone line. *For more details, please refer to the materials available for download from the <Download Catalog> link. Feel free to contact us with any inquiries.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration
Do you have any of these concerns? - Prevention of intruders, theft, and fires in orchards - This is ●● Farm. We have detected an intruder. The notification device (WhiteLock) fundamentally solves these issues. ◇ By installing photoelectric sensors (beam sensors) at the four corners of the orchard, we can detect suspicious individuals at night and send alerts. ◇ If you wire the alarm signals from the photoelectric sensors (beam sensors) to the notification device (WhiteLock), it will send an alert when the sensors detect something. *For more details, please refer to the materials by downloading the catalog. Feel free to contact us as well.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration
Do you have any of these concerns? - Investigating the cause after something runs out takes time for recovery. - It is necessary to constantly monitor the condition of the entire equipment. The reporting device (WhiteLock) fundamentally solves these issues. ◇ By simply wiring alarm signals (power outages, malfunctions) from each measuring device (water level gauge, flow meter), pumps, and boilers to the reporting device (WhiteLock), hot spring facilities can be monitored remotely 24 hours a day, 365 days a year. ◇ Alarm signals can also be transmitted using low-power radio to locations with telephone lines. *For more details, please refer to the materials available for download in the catalog. Feel free to contact us with any inquiries.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration
Do you have any of these concerns? - Since radio broadcasting relies on public airwaves, it is necessary to ensure that there is no period of silence for a certain duration. - Therefore, it is crucial to respond quickly when the silence detector or monitoring tuner detects an anomaly. The reporting device (WhiteLock) fundamentally resolves these issues. ◇ By simply wiring the alarm signals from the silence detector and monitoring tuner to the reporting device (WhiteLock), you can monitor 24 hours a day, 365 days a year. ◇ The alarm signals can also be transmitted using low-power radio to locations with telephone lines. *For more details, please refer to the materials available for download in the catalog. Feel free to contact us with any inquiries.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration
Do you have any of these concerns? - In buildings or apartments, failures or power outages of electrical (lighting and power supply) equipment, air conditioning systems, and water supply and drainage systems require immediate response. The reporting device (WhiteLock) fundamentally solves these issues. ◇ By simply wiring alarm signals (failures, power outages) from equipment to the reporting device (WhiteLock), you can monitor the equipment 24 hours a day, 365 days a year. ◇ Alarm signals can also be transmitted using low-power radio to locations with telephone lines. *For more details, please refer to the materials available for download in the catalog. Feel free to contact us with any inquiries.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration
Do you have any of these concerns? - Remote monitoring of temperature, humidity, boiler abnormalities, and power outages in a greenhouse. - The WhiteLock (notification device) receives alarm signals for temperature and humidity anomalies, power outages, boiler failures, etc., and reports them. The notification device (WhiteLock) fundamentally solves these issues. ◇ By simply wiring alarm signals (temperature, humidity, power outages, failures) from inside the greenhouse to the notification device (WhiteLock), you can remotely monitor the environmental conditions inside the greenhouse 24 hours a day, 365 days a year. ◇ Alarm signals can also be transmitted using low-power radio to locations with telephone lines. * For more details, please refer to the materials available for download in the catalog. Feel free to contact us with any inquiries.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration
Do you have any of these concerns? - The basic electricity charge is determined by the contracted power, which is updated based on the demand value (maximum demand power). - If the electricity usage exceeds the contracted power, you will have to pay an excess charge or your contracted rate will increase. - Therefore, it is important to monitor demand to avoid exceeding the contracted power. The reporting device (WhiteLock) fundamentally solves these issues. ◇ By simply wiring the alarm signals from the demand monitoring device to the reporting device (WhiteLock), you can monitor demand 24 hours a day, 365 days a year. ◇ The alarm signals can also be transmitted using specific low-power radio to any location with a telephone line. *For more details, please refer to the materials available for download from <Download Catalog>. Feel free to contact us with any inquiries.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration
Do you have any of these concerns? - You can monitor the temperature of food that requires a constant temperature for 24 hours. - You want to respond to temperature anomaly alarms and malfunction alarms from food showcases. The reporting device (WhiteLock) fundamentally solves these issues. ◇ By simply wiring the alarm signals (temperature, power outage, malfunction) from the food showcase (food storage device) to the reporting device (WhiteLock), you can monitor the temperature of food that requires a constant temperature for 24 hours. ◇ The alarm signals can also be transmitted using low-power radio to locations with telephone lines. *For more details, please refer to the materials available for download in the catalog. Feel free to contact us with any inquiries.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration
Do you have any of these concerns? - In a server room, managing temperature and humidity is crucial for the stable operation of servers. - If servers exceed the appropriate temperature range and fail, or if a server goes down, it can lead to significant losses such as disruptions in communication networks. The reporting device (WhiteLock) fundamentally solves these issues. ◇ By simply wiring alarm signals (temperature, humidity, abnormalities) from air conditioning equipment and various sensors to the reporting device (WhiteLock), you can remotely monitor the server room 24/7, 365 days a year. ◇ Alarm signals can be transmitted using low-power radio to locations with telephone lines. *For more details, please refer to the materials available for download from <Download Catalog>. Feel free to contact us with any inquiries.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration
Do you have any of these concerns? - A forced entry signal has been detected. - The alarm signal for forced entry is received by WhiteLock (the reporting device), which will notify you. The reporting device (WhiteLock) fundamentally solves these issues. ◇ By installing vibration sensors and impact sensors on automatic payment machines, it reports abnormalities such as forced entry. ◇ If you wire the alarm signals (vibration or forced entry signals) from the automatic payment machine and sensors to the reporting device (WhiteLock), it will notify you when the sensors detect something. *For more details, please refer to the materials available for download in the catalog. Feel free to contact us with any inquiries.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration
Do you have any of these concerns? - Out of change. - Change shortage or gate malfunction. The reporting device (WhiteLock) fundamentally solves these issues. ◇ By simply wiring the alarm signals (out of change, malfunction) output from the control panel of the automatic payment machine installed in coin parking (unmanned parking lot) to the reporting device (WhiteLock), you can monitor the automatic payment machine 24 hours a day, 365 days a year. ◇ The alarm signals can also be transmitted using specific low-power radio to locations with telephone lines. *For more details, please refer to the materials available for download from <Download Catalog>. Feel free to contact us with any inquiries.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration
Do you have any of these concerns? - If an abnormality occurs in the dialysis fluid supply device or RO device, immediate action is necessary. - Additionally, by quickly responding to abnormalities after dialysis operations at unmanned clinics at night, you can ensure a smooth start to the dialysis operations the following morning. The reporting device (WhiteLock) fundamentally resolves these issues. ◇ By simply wiring the alarm signals from the dialysis device to the reporting device (WhiteLock), you can monitor 24 hours a day, 365 days a year. ◇ The alarm signals can also be transmitted using specific low-power radio to locations with telephone lines. *For more details, please refer to the materials available for download in the <Catalog>. Feel free to contact us with any inquiries.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration
Do you have any of these concerns? - When high-voltage receiving equipment fails and causes a power outage, not only are the costs for equipment repairs incurred, but in factories and similar settings, production stops, leading to additional losses. - Therefore, it is essential to monitor for leakage, power outages, and failures 24/7. The reporting device (WhiteLock) fundamentally resolves these issues. ◇ By simply wiring alarm signals (leakage, insulation, power outage, transformer overheating) from within the cubicle to the reporting device (WhiteLock), it enables 24/7, 365-day monitoring of the cubicle. ◇ Alarm signals can also be transmitted using low-power radio to locations with telephone lines. * For more details, please refer to the materials available for download from <Download Catalog>. Feel free to contact us with any inquiries.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration
Do you have any of these concerns? - It allows for early detection if the box trap closes while empty or in the case of accidental captures. - If utilizing for meat, it enables rapid processing from capture. The notification device (WhiteLock21MM) fundamentally solves these issues. ◇ When the door of the box trap closes, it receives a contact signal and can notify a pre-set contact via "voice notification" or "SMS notification." ◇ Since you can understand the status of the box trap, it is expected to reduce the effort required for patrols and improve operational efficiency. *For more details, please view the materials by downloading the catalog. Feel free to contact us with any inquiries.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration
Do you have any of these concerns? - In underpasses (subways) that go under roads and railways, it is necessary to alert pedestrians and vehicles of danger when flooding occurs. - Especially during localized heavy rain (guerrilla rain), it is important to respond quickly and accurately to alert drivers on-site to prevent accidents such as vehicle submersion. The reporting device (WhiteLock) fundamentally solves these issues. ◇ By simply wiring the alarm signal from the water level gauge to the reporting device (WhiteLock), remote monitoring is possible 24 hours a day, 365 days a year. ◇ The alarm signal can be transmitted using specific low-power radio to locations with telephone lines. *For more details, please refer to the materials available for download in the catalog. Feel free to contact us with any inquiries.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration
Do you have any of these concerns? - Noticing temperature abnormalities in prefab refrigerators and freezers too late, only checking alarms or thermometers in the morning. - Being unable to grasp abnormalities until the responsible person arrives on-site, even if the internal temperature rises during the night or on holidays. - The hassle of temperature recording and patrol checks leading to food and raw material disposal or shipment halts when equipment troubles occur. The remote notification device 'WhiteLock21MM' fundamentally resolves these issues. ◇ Remote monitoring of temperature abnormalities via LTE communication It monitors input signals from temperature sensors and other sources to grasp temperature abnormalities in prefab refrigerators and freezers remotely. ◇ Notification via phone or SMS when abnormalities occur Abnormalities are reported to the designated contacts via voice calls or SMS. This allows the responsible person to understand the situation before arriving on-site, facilitating initial response actions. ◇ Monitoring of equipment abnormalities beyond temperature with a single unit Supports up to 8 input signals. It can manage multiple monitoring applications, including power outages, water levels, and security, in addition to temperature abnormalities. It helps reduce the time from abnormal occurrence to on-site confirmation, thereby alleviating patrol burdens and minimizing loss risks due to temperature abnormalities. *For more details, please refer to the materials available for download from <Download Catalog>.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration
Do you have any of these concerns? - Every time there is heavy rain or a typhoon, I feel anxious about the manhole pump overflow and go to check the site at night. - Delays in discovering sudden power outages, overloads, leakage, or pump failures have led to complaints from nearby residents. - The introduction of complex remote monitoring systems is costly, and I cannot afford the hassle of setup and wiring work. The manhole monitoring notification device "WhiteLock" fundamentally solves these issues. ◇ Easy installation by simply wiring to the control panel's voltage-free contact signal ◇ Instantly reports alarm signals for overload, water level, leakage, failure, and power outages without missing any ◇ Automatically detects abnormalities in manhole pump equipment 24/7, 365 days a year By implementing this system, the speed of response during trouble occurrences is significantly improved, dramatically reducing the mental burden on field workers and unnecessary nighttime patrol labor. *For more details, please refer to the materials available for download in the catalog. Feel free to contact us with any inquiries.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration
This is a device that transmits contact signals using specific low-power wireless technology. The transmission distance is 1000 meters in line of sight, making it suitable for wide areas. Additionally, up to 10 relay units can be used. *Line of sight means that the antennas can see each other. If there are obstacles preventing the antennas from seeing each other, it is not considered line of sight. *It can only be used in a one-to-one configuration; one-to-many configurations are not possible. Since contact signals are transmitted wirelessly, there are no communication costs involved.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration
Remote monitoring is possible using a standard line (telephone line). There are 4 input signals, and depending on the environment of the reporting destination, both "voice reporting" and "text message reporting" are available. Additionally, you can select the input signals to monitor for each reporting destination. ~ Please check the details in the catalog first!! ~
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration
The input signal has 8 contacts, and depending on the environment of the reporting destination, it is possible to use "voice reporting" or "text message reporting." Additionally, you can select the input signals to monitor for each reporting destination. ~ Please check the details in the catalog first!! ~
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration
The LTE (4G) communication module is built-in, allowing for remote monitoring in environments without a general line. It is possible to use NTT Docomo's LTE (4G) wireless for "voice reporting" and "SMS email reporting," with a maximum of six settings for each.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration
- It is a device that transmits contact signals using specific low-power radio. - Remote monitoring and remote control are possible using specific low-power radio. - The transmitter has 8 input signal contacts, and the receiver has 8 output signal points, operating in synchronization with each other. - The reachable distance is approximately 1000 meters at a height of 1.5 meters in an open rural area (however, this is only applicable in environments with low noise and without surrounding influences. The distance may be shorter depending on installation conditions, such as the presence of obstacles like buildings or mountains). - It can only be used in a one-to-one configuration. It cannot be used in a one-to-N configuration.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration
●Prevents unnecessary battery consumption The standby power when the main unit is switched on is about 0.3 watts. ●Notifies with sound and buzzer when voltage drops When the battery voltage drops below 11.5V, a warning buzzer (beep beep) sounds every 30 seconds, and a blue light turns on. When the battery voltage drops below 11.0V, an SOS buzzer (beep beep beep beep beep ...) sounds, and a red light turns on. The load will be disconnected within 30 seconds. ●Notifies with sound and buzzer when the heat sink becomes too hot When the temperature of the heat sink exceeds 50°C, an SOS buzzer (beep beep beep beep beep ...) sounds, and a yellow light flashes. If the temperature does not decrease after 60 seconds, the load will be disconnected.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration
This is a device that warns with a buzzer sound when the key is removed while the vehicle's small lights or headlights are still on, in order to prevent battery drain. It features a microcontroller and has an easily understandable alarm sound, with a current draw of only a few mA while the lights are on, making it very energy-efficient. Additionally, the main body case is compact, measuring W30×H20×D40.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration