316~360 item / All 372 items
Displayed results
Filter by category
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationContact this company
Contact Us Online316~360 item / All 372 items
Filter by category
■ The UPS pump has a circulator pump with three speeds (50Hz and 60Hz). ■ These pumps can be used in both open and closed systems. The pump and motor form an integrated unit with two gaskets instead of a shaft seal, and they are of the canned rotor type. Additionally, the bearings are lubricated with the conveyed liquid. ■ Designed for liquid circulation in heating and air conditioning systems. Pumps with copper or stainless steel housings can also be used in hot water service systems.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration■Grundfos TP and TPE vertical inline pumps can be used for various applications. All pumps are single-stage inline centrifugal pumps equipped with standard motors and mechanical shaft seals. These are close-coupled pumps where the pump and motor are independent units. Compared to similar canned rotor pumps, they have the advantage of being unaffected by impurities in the conveyed liquid. ■There are two models of vertical inline pumps. We offer a wide range of special product options for each model. 【TP Pump】 This pump is characterized by excellent reliability and high efficiency. For models with 7.5KW 4P and 11KW 2P or higher, a quiet IE2 motor with high-efficiency operation is standard. The pump body of the TP pump is all coated with electrodeposition paint, ensuring excellent corrosion resistance. 【TPE Pump】 The main difference between the TP pump and the TPE pump is the motor. The TPE motor has a built-in frequency converter, allowing for different control methods to be applied. The TPE pump saves energy and improves comfort.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration- Ducted air blowing is possible with clean hot air. - Stacking storage is possible (HS290L1: 3 tiers, HS290-L1T80: 2 tiers). - Equipped with a large-capacity oil tank (80L), allowing for 18 hours of continuous operation (HS290-L1T80).
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration- Air blowing operation Can operate with air blowing only. - Alarm monitor Notifies the operation status of safety devices via lamps or error codes. - Earthquake (earthquake automatic extinguishing) Automatically extinguishes in the event of a strong earthquake or shock. - Ignition (ignition safety) Automatically extinguishes in cases of ignition failure, mid-operation extinguishing, abnormal combustion, or fuel depletion. - Power outage (power outage safety) Prevents automatic operation from starting even after power is restored following a power outage. - Overheating prevention Automatically extinguishes when the heater's interior overheats abnormally. - Overload (overload protection) Stops operation by cutting off the electrical circuit in the event of an overcurrent. - High voltage (high voltage stop) Stops operation when the power supply voltage becomes abnormally high during operation. - Low voltage (low voltage alarm) Issues an alarm when the power supply voltage is abnormally low.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe warm air jet heater is different from the infrared type; it is a heater that uses a fan to distribute the heat from the burner. Due to its convection method, it is particularly effective for drying applications.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe warm air jet heater is different from the infrared type; it is a heater that uses a fan to distribute the heat from the burner. Due to its convection method, it is particularly effective for drying purposes. There is also an energy-saving type that reduces kerosene consumption.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationWe have achieved efficient low fuel consumption by reducing fuel consumption during weak combustion. The position of the control panel has been raised, improving visibility and ease of use. The individual alarm monitor allows for immediate identification of the cause of safety device activation. It features a large-capacity tank that can sustain combustion for over 10 hours.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe warm air jet heater is different from the infrared type; it is a heater that uses a fan to distribute the heat from the burner. Due to its convection method, it is particularly effective for drying applications. The odor during ignition has been significantly reduced to less than 1/5 (compared to the same company). It is also ideal for interior-related spaces of 10 tsubo or more.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationEquipped with a rotary gasification burner, it operates quietly with a sound level below 58 dB. Weighing only 11.5 kg, it is easy to transport (when the tank is empty) and features a clearly visible warning lamp that minimizes the risk of kerosene spilling during transport or if it tips over.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationJet heaters are used not only for outdoor and indoor heating in schools, gymnasiums, golf practice ranges, tennis courts, driving schools, funeral homes, event venues, logistics warehouses, factories, and greenhouses, but also for drying purposes such as painting and curing concrete at construction sites. They can be stacked for storage, so they do not take up space during the off-season.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationIt can be used not only for outdoor and indoor heating but also for drying in construction site painting and concrete curing. It is also well-received as graduation commemorative gifts and PTA donations. It is a general-purpose type that takes into account the introduction cost. It comes standard with six types of safety devices and alarm monitors.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationQuiet operation sound (combustion and airflow at minimum: 58db) with wide heating at 30 degrees to the left and right. Combustion and airflow levels can be adjusted in five stages. We have thoroughly pursued the longevity of the automatic oscillation mechanism. (3-year warranty on the oscillation mechanism *Excludes failures due to improper handling or natural disasters.)
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationJet heaters are used in schools, gymnasiums, golf practice ranges, tennis courts, driving schools, funeral homes, event venues, logistics warehouses, factories, and greenhouses. With the double power of infrared and warm air, they provide wide warmth with low fuel consumption.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration- Stacking (Stacking Storage) When stored, it can be stacked in three layers. - Long Duration (Long Duration Combustion) When the oil tank is full, combustion lasts for over 14 hours. - 3P Cord It is a power cord compatible with both 2P and 3P (Pockin plug). - Alarm Monitor It notifies the operation of safety devices via a lamp or error code. - Earthquake Resistance (Earthquake Automatic Extinguishing) It automatically extinguishes in the event of a strong earthquake or shock. - Ignition (Ignition Safety) It automatically extinguishes in cases of ignition failure, mid-combustion extinguishing, abnormal combustion, or running out of oil. - Power Outage (Power Outage Safety) It prevents automatic operation from starting even after power is restored following an outage. - Overload (Overload Protection) If excessive current flows, it cuts off the electrical circuit and stops operation. - High Voltage (High Voltage Stop) Operation stops when the power supply voltage becomes abnormally high during operation. - Low Voltage (Low Voltage Alarm) An alarm is triggered when the power supply voltage is abnormally low.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe Jet Heater/Eco Silence HRR480B-S is an eco-friendly heater that provides more warmth with less fuel, considering both energy conservation and CO2 reduction. With the automatic eco operation feature and the newly added thermo operation function, it achieves approximately 38% energy savings. Efficient radiation panels and burner heating allow it to provide the same warmth as conventional models while using 30% less kerosene. With an operating noise level of 53 to 57 dB, it is also ideal for quiet places. Compared to electric heaters, it excels in both energy conservation and CO2 reduction, making it a cost-effective heater with low running costs.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration■ Lightweight, space-saving, and energy-efficient without a power supply. The main unit requires no power and weighs only 10kg (for ODF5-W1). Achieves zero floor space by being wall-mounted. Running cost is 6.3 yen/L. ■ Uses an element-based system for consumable replacement. Easy and reliable for anyone. Element replacement time is 6 minutes. Can be replaced during lunch breaks. ■ Various ways to use it. For equipment with low operating frequency. As a "pre" drain processing unit for existing equipment.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration■ Measurement/display of the dew point (at atmospheric pressure) and temperature of the refrigerated air dryer is possible (digital display of conventional refrigerant pressure and compressed air cooling temperature). ■ Standard analog output equipped (single output). ■ Slim and compact (62% volume ratio of MG40A-P). ■ External communication function allows management of up to 8 units via PC (optional feature).
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration【MG40 (For Atmospheric Air Only)】 - Simultaneous display of temperature, humidity/dew point (humidity/dew point can be switched). - Dew point/humidity alarm output standard equipment (with two non-voltage contacts). - Standard analog outputs (temperature, humidity/dew point: DC output). 【MG40A-P (For Compressed Air Only)】 - Simultaneous display of temperature, humidity/dew point (humidity/dew point can be switched). - Dew point/humidity alarm output standard equipment (with two non-voltage contacts). - Standard analog outputs (temperature, humidity/dew point: DC output).
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration■When the instantaneous air consumption exceeds the total discharge amount of the air compressor. ■When using two or more air compressors to average the load rate. ■In front of a heatless air dryer.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration■The tank is made of SUS304 material. The surface of the tank is finished with paint (metallic silver). The plugs for the cleaning and inspection holes are made of FC material. We also accept orders for SUS specifications, so please feel free to inquire. ■Ideal for industries such as food, medical, and semiconductor, where rust is undesirable.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration■ Uses a special spiral tube, demonstrating excellent heat transfer capability 2 to 3 times that of bare tubes. ■ Adopts a self-cleaning (self-purification) method.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration■Ideal for heatless dryers. ■Adopts a wide-pitch condenser that is easy to maintain.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration■Ideal for 11 to 150 kW air compressors. ■Adopts a wide-pitch condenser for easy maintenance. ■Uses wave-shaped fins. The thin heat exchanger with good heat transfer efficiency has a large air contact area, demonstrating excellent cooling capability. ■Special fan adopted to minimize air flow unevenness.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration【Motor Valve Type Drain Trap: ADE-2-B/3-B】 ■ Automatically discharges drain with water detection sensor. ■ Discharge cycle time can be set with variable timer (ADE-3-B). 【Float Type Drain Trap: FD2/2-NC/5/6-G3/10-A】 ■ Discharges drain without air loss (FD2・5・6・10-A). 【Disk Type Drain Trap: AD-5-G1】 ■ Discharge interval is variable.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration【Timer-type Drain Trap: ADE4B】 - The discharge interval can be set with a variable timer. - Equipped with an energy-saving function that automatically controls the discharge interval based on ambient temperature detection. - Significantly reduces clogging of sludge and other materials by adopting a large-diameter orifice solenoid valve. - Equipped with a freeze prevention function that automatically shortens the discharge interval during low temperatures. 【Electromagnetic Drain Trap: ADE300】 - Equipped with a capacitive liquid level sensor. - Prevents clogging of foreign objects by adopting a large-diameter orifice solenoid valve. - Remote management is possible (operating signal and alarm signal are standard features).
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration■No power supply is required at all. ■Adopts a variable type that allows adjustment of the discharge temperature and airflow of cold air. You can achieve the optimal combination of cold air temperature and discharge volume according to the cooled object and various working conditions. ■Long lifespan.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration■No power supply. ■Equipped with a dew point indicator for checking dehumidification status. ■No vibration, no heat discharge, and easy maintenance. ■No drain generation. The removed moisture is discharged as water vapor, so no drain is generated. ■Compact, lightweight, and space-saving (compared to our refrigerated air dryers). Approximately 1/5 the installation space and less than 1/10 the weight.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration■Simply set it in the duct to easily supply dehumidified air. The unique expansion separation method achieves lightweight and compact design. Furthermore, since it does not require a power supply, you can easily provide dehumidified air. ■Unique structure that follows flow rate fluctuations. It ensures reliable dehumidification performance even during fluctuations in flow rate and pressure, making it ideal for air management at the end point. ■Achieves maintenance-free operation. There is no clogging since no filters are used. Additionally, the drain is automatically discharged from the auto drain trap.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration■ Four types: for water droplet and solid removal, for solid removal, for oil mist removal, and for odor removal. (A total of 20 models are available) ■ Can be connected with a tie rod, allowing for reduced piping space (optional support available)
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration■High-precision filtration. Removes particles of air cleanliness ISO 14644-1 Class 3 (F.S. 209D Class 1). ■Compact and lightweight. ■Easy maintenance. Features a cartridge-type filter that is easy to replace.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration■Achieves high cleanliness of compressed air. ■Capable of precise filtration at 0.5μm. ■Casing is finished with SUS polishing, and the element uses PTFE membrane or fiberglass. ■Standard equipped with an outlet particle measurement port.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationOrion Machine's compressed air filters (compressed air purifiers) allow you to choose from various filters tailored to different removal levels for water droplets, solids, oil mist, odors, and more in compressed air.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration■Cooling is achieved simply by placing the cooling coil in the tank. ■Lightweight design allows for easy movement and installation. ■Uses cooling coils with excellent chemical resistance (two types: SUS304 and titanium). ■By installing a liquid temperature controller (optional), constant temperature control is possible.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationYou can choose from various filters tailored to the removal levels of water droplets, solids, oil mist, odors, and more in compressed air.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationOrion's compressed air filters (compressed air purifiers) allow you to choose from various filters tailored to different removal levels for water droplets, solids, oil mist, odors, and more in compressed air.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationCompressed air filters (compressed air purifiers) allow you to choose from various filters tailored to different removal levels for water droplets, solids, oil mist, odors, and more in compressed air.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration- Standard equipment includes the first stainless steel container in its class (over 400). - Newly developed "fiber-like activated carbon" adopted. - Significantly reduced the outflow of activated carbon particles to the secondary side compared to conventional granular activated carbon. - Reduced outlet oil concentration to 0.003 wtppm. - By adopting the newly developed element and combining it with line filters and mist filters, the outlet oil concentration is significantly reduced, providing cleaner air. - Expanded pressure range (150B to 250B). - Tie rod connection (150B to 250B). - Diameter selection available (400, 1000).
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration- Standard adoption of stainless steel containers for the first time in the class (400-1 and above). - Standard adoption of clamp joint method (400-1 to 2000-1). The adoption of a band structure simplifies the housing removal process compared to the conventional flange method. - By adopting a newly developed element, the normal pressure loss value is reduced to 0.02 MPa (a 33% reduction compared to our previous models). - The timing for element replacement is indicated by a ramp (400-1 and above). Element life indicator adopted. - Expanded pressure range (75B to 250B). - Tie rod connection (75B to 250B). - Diameter selection available (400, 1000).
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration- Standard adoption of stainless steel containers for the first time in the class (400-1 and above). - Standard adoption of clamp joint method (400-1 to 2000-1). The adoption of a band structure simplifies the removal of the housing compared to the conventional flange method. - Improved water resistance achieved through the adoption of newly developed elements (200% compared to our previous models). - Expanded pressure range (75B to 250B). - Tie rod connection (75B to 250B). - Diameter options available (400, 1000).
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration■ Adoption of stainless steel pressure vessels (400-1 and above). ■ Achieves high efficiency and stable separation efficiency. Utilizes an element filtration method, ensuring no decrease in separation efficiency due to fluctuations in flow rate. ■ Low pressure loss (below 0.005 MPa). ■ Expanded pressure range (75B to 250B). ■ Tie rod connection (75B to 250B). ■ Diameter selection available (400, 1000).
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration■ Significant energy savings achieved through energy-saving dew point sensors. ■ Digital dew point monitor enables dew point monitoring and further energy savings. ■ Energy-saving control possible with any dew point setting from -60 to 0°C (under pressure). (Dew point display accuracy: -60°C to +20°C ±3°C) ■ Equipped with a digital dew point monitor. ■ Standard features include dew point alarm output (with two voltage-free contacts and standby sequence) and analog output (DC 1-5V (-80 to +20°C)). ■ Remote monitoring of compressed air quality and dew point is possible.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration■Freon-free Air Dryer The heatless air dryer QSQ series removes water vapor from compressed air using a desiccant. Unlike refrigerated air dryers, it can supply freon-free air with a low dew point. The regeneration of the desiccant is achieved by passing a portion of the dried air through it (purge air). ■Energy-saving dew point sensor is standard equipment. (Medium-sized series) ■All functions are displayed with lamps. ■Compact, lightweight, and easy to maintain.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration■ Energy-saving mode switch for dew point temperature. In addition to a dew point of 10°C under pressure, 18°C is also selectable. This enables significant energy savings during high-temperature periods. Additionally, it is possible to prevent condensation caused by the difference in outdoor temperature. A feature has been added to automatically adjust the dew point setting under pressure in conjunction with the outdoor temperature (for models RAXE4900 and above). ■ Achieves up to 60% energy savings. Through the unique development of "frequency PID control of the inverter compressor" and "infinitely variable PID control of the electronic expansion valve for optimizing the refrigeration cycle," significant energy savings have been achieved even during normal operation compared to the conventional RAX series (CCV control). Furthermore, when the dew point under pressure is set to 18°C, up to 60% energy savings are possible (RAXE4900 model achieves up to 53%). ■ Responds to low-pressure needs (0.54MPa standard). In response to low-pressure needs, the design standard pressure has been changed from 0.69MPa to 0.54MPa. There is no need for a rank upgrade in model selection at low pressure (for models RAXE2300 to 4900). ■ Continuous operation even under high load. With unique control, continuous operation is maintained even under unexpected high loads, making it difficult to stop before safety devices are activated through self-protection control. ■ Inverter control allows for the same capacity at 50Hz and 60Hz.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration■Equipped with a digital control compressor for energy savings. Energy-saving operation that follows load fluctuations (up to 68% energy savings). Energy-saving operation through manual and automatic changes of the dew point setting (linked to outside temperature) (10℃ to 18℃). ■High inlet temperature compatible model (inlet air temperature 5℃ to 80℃). ■Optimized design Minimizes alarm shutdown during high load operation in summer through self-protection/control. Reduces exhaust heat in energy-saving operation. *Custom SUS pipes are available to improve corrosion resistance.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration■ Achieves energy-saving operation with DC inverter control. Realizes energy-saving operation (up to 65%) that follows load fluctuations with the industry's first DC inverter compressor control. ■ Safe and secure design with additional features. 1. Design compatible with increased airflow for air compressors. 2. Automatic switching function linked to ambient temperature and dew point. 3. Optimization automatic control and ability to check operating status. 4. Designed to be less prone to tripping even during high load in summer. 5. Condenser exhaust directed upwards. 6. Drain discharge can be changed to the left side or rear. 7. Corrosion-resistant heat exchanger (uses stainless steel shell and nickel-plated copper pipes). *Custom SUS pipes are available to improve corrosion resistance. ■ Environmentally friendly Compliant with RoHS directive.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration