1~45 item / All 90 items
Displayed results
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationContact this company
Contact Us Online1~45 item / All 90 items
The "KEL-2" is a level switch that detects the measured object by the change in resistance occurring between the electrode and the metal tank wall. The main features are as follows: - No moving parts! Maintenance costs can be reduced. - Sensitivity can be easily adjusted. - Can withstand severe impact loads from bulk materials. - Installation and handling are very simple! No difficult knowledge or skills are required. - Usable for a wide range of materials, such as gravel and crushed stone, as long as they contain a certain amount of moisture. *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe laser level meter "LASER-RANG-S" is designed for short-distance measurements up to 10 meters, pursuing compact size, lightweight, and low cost. It can be installed with a small diameter fitting (G2 screw-in) and allows measurements from outside the tank. ■ Examples of Use - Distance measurement of colored material surfaces inside small tanks - Level measurement of open containers by ceiling installation - Level measurement in crushed stone and grinding equipment - Non-contact measurement of food and processed products, etc. For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationFlowJam T is a sensor that monitors the flow of powder transported through thin tubes or hoses. The sensor can be used with hoses made of non-conductive materials such as plastic or rubber, with an outer diameter of 4 to 25 mm, and is mounted around the measurement hose for measurement. ■ Capable of measuring powder flow in tubes or hoses with a diameter of φ4mm to φ25mm ■ No specified measurement direction ■ Easy installation with clamp-on mounting ■ Parameters can be set and data logging can be performed using dedicated software on a PC *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe Electro-Dynamic Dust Monitor LeakAlert73 (integrated type) and LeakAlert65-02 (separated type) have obtained domestic explosion-proof certification, so they can be used in explosion-proof areas. <Integrated Type Explosion-Proof> Model: LeakAlert73X Explosion-Proof Structure: Dust explosion-proof structure "t" by container Applicable Zone: Zone 20 <Separated Type Explosion-Proof> Model: LeakAlert65-02X Explosion-Proof Structure: Dust explosion-proof structure "t" by container Applicable Zone: Zone 22 We can assist with explanations of the dust monitor, selection of sensors suitable for usage conditions, and we also offer the possibility of lending test products, so please feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationIntroducing the special specifications of the horizontal mounting float switch in the KF-200 series, which reliably captures the liquid level with a simple structure! - Float with Bellows: Model KF-209 The bellows prevent the intrusion of fine solid particles mixed in the measuring liquid into the float's moving parts, ensuring it continues to operate. - Rust-resistant Bellows Float Switch: Model KF-207BR To prevent rust caused by standard stainless steel materials in seawater, the float is made of PVC, and the liquid contact parts are coated with tar epoxy. - Horizontal Type Vertical Mounting: Model KF-207F When viscous liquids or liquids mixed with impurities and debris are mounted horizontally, there is a possibility of them entering the moving parts. This model is suitable for cases where vertical mounting from the top of the tank is desired. Additionally, we manufacture level switches suitable for various applications, including explosion-proof specifications, heat-resistant specifications, models with operation confirmation test levers, two-contact output specifications, and products that have obtained NK certification. If you have any concerns regarding liquid level measurement, please feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration<Product Lineup> 1. Standard Type NL Series 2. Low-Cost Type NM Series 3. Optimal Dual-Rotation Type NNL Series for conditions with fluidity in the tank and frequent powder changes 4. Low-Cost Type NNM Series with common parts to the NNL Series 5. Pressure-Resistant Explosion-Proof Type FL-GM Series for use in explosive atmospheres Each series offers the following specifications: 1. Extended Protection Tube Type → Custom lengths available 2. Heat-Resistant Type → Supports up to Max. 250°C (NL Type) 3. Shaft Length Adjustment Type → Ideal for on-site adjustments in tanks with a resting angle * For upper limit detection only 4. Load-Bearing Type → Ideal for lower limit detection 5. Flexible Shaft Type → Optimal for conditions where load is applied to the detection vane 6. Protective Cover Type → Best for environments where overload occurs near the tank lower limit or inlet 7. Angled Flange Type → For installation on the conical part of the tank If you have any other requests, we will utilize our years of experience and technical expertise to creatively develop suitable rotary types. If you have any issues with powder measurement, please feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe indoor working environment measuring device AirSafe2 measures dust particles in the atmosphere captured by an induced fan and outputs an alarm contact when the set concentration is exceeded. It is capable of continuously monitoring the invisible fine dust generated within the factory. <Features> - Compact design allows for flexible placement! - Ready to use immediately after installation! - Easy to change settings! - Simple maintenance! - Explosion-proof type is also available! *For more details, please refer to the attached PDF or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationStarting with the "VIEW370," which can be used for measuring dust concentration in various processes, we also offer the "VIEW Ex800," which can measure in hazardous areas. Despite having one of the most advanced features in dust monitoring, it achieves high-speed data processing. 【Features】 ■ Almost unaffected by adhesion or dirt on the probe ■ Ultra-high sensitivity of 0.01 to 1000 mg/m3 ■ PTFE and FRP coatings can be manufactured (VIEW370・370PRO) ■ Capable of measuring high humidity gases with special air purging (VIEW370・370PRO) ■ Free power supply: AC 90 to 260V ■ Capable of withstanding ultra-high temperatures: MAX 800℃ ■ Supports up to 16-channel sensors (VIEW370PRO) ■ Can be connected to a common bus with other models from our company (VIEW370PRO) *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe KSL-DS4 type is a microprocessor-controlled controller that can connect up to four of our sounding type level meters. It converts the measurement distance of the instrument into the storage volume in the tank, and can be set to display either the empty volume or the remaining volume. The tank display can be selected with a single touch, and it can be set up with a flexible detection method according to the application. <Compatible Models> KSL-T8 (AU) type, KSL-T2 type, KSL-W3T type, KSL-W2B type
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationPlease use our products in the following wastewater treatment processes: - For sewage pipes carrying household wastewater, ultrasonic or flow meters - For sedimentation tanks, ultrasonic, capacitive, or ball float types - For sewage pumps in pump chambers, ultrasonic or electrode types - For settling tanks, underwater sludge level meters, electrode types - For digestion tanks, microwave or capacitive types, etc. We also offer a variety of sensors that are optimal for wastewater treatment systems and can assist in selecting the appropriate sensors for your specific applications. *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationAdvantages of Non-Contact Level Gauges - No concerns about foreign matter contamination due to breakage or wear since it is non-contact - Capable of long-span measurements - Easy to install in hard-to-reach places such as high locations - Usable in vacuum, high temperature, and high pressure environments (radar type) Disadvantages of Non-Contact Level Gauges - There is a "non-measurable zone" where measurements cannot be taken at a certain distance from the sensor tip. - If the properties of the measured substance in the tank change, it is prone to malfunction... - Initial setup is required Non-Contact Continuous Level Gauges - Radar type - Ultrasonic type - Laser type *For details on the models you are interested in, please refer to the PDF materials or feel free to contact us. *We will select the appropriate model based on usage conditions, etc.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration<Operating Principle> It consists of an electro-dynamic sensor integrated with an induction fan. When air is drawn in from the induction fan, a flow of 100m³/h (130m³/h for explosion-proof type) is generated, and the charge amount of the charged particles carried by this airflow is measured. The measurement signal can be output in analog form, and if an abnormality occurs in the fan, it will be indicated by an LED. <Features> - Compact design that allows for flexible placement! - Usable immediately after installation! - Easy to change settings! - Simple maintenance! - Explosion-proof type is also available! *For more details, please refer to the attached PDF or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe KF-300 series is a vertical float switch for liquid measurement. It has a simple structure that makes it easy to handle. Additionally, since it uses a reed switch, it can also withstand humidity, gas, and dust. We offer a variety of materials and float sizes to accommodate different liquids. Furthermore, while it is a point measurement level switch, it can detect multiple points by increasing the number of reed switches. We can also accommodate challenging usage conditions with options such as a wave-damping tube, relay joint specifications, and ribbed floats, so please feel free to consult us. For more details about the product, please refer to the attached PDF.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThis is a capacitive level switch that can be used for various applications with over 1,000 types of electrode shapes and special circuits. It reliably detects even in the following situations: 1. For measurement objects with electrode adhesion or deposits, unique correction functions ensure that adhesion and deposits are not detected. 2. For use in areas with severe vibrations, it is equipped with amplification separation and vibration-resistant measures. 3. For corrosive measurement objects, Teflon-coated electrodes can be used (depending on the measurement conditions). 4. There are no issues with installing multiple units in the same tank (however, if the installation spacing is short, interference countermeasures are required). 5. If you want to detect interfaces, it can be adapted by referring to the relative permittivity of the two liquids, provided the conditions are met. 6. For use in areas with significant temperature differences, there is a condensation prevention specification (indoor use only, with air holes). 7. If you want to confirm ON/OFF without going to the site, there is a version with a visible operation indicator light. 8. If chattering causes frequent ON/OFF repetitions, the ALN type comes standard with an ON delay function (an OFF delay option is also available). If you have any other concerns, please feel free to consult us, and we will help you select the appropriate model for your use.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationPlease use this when you are having trouble with the following: ■ Issues with using a rotary level switch - Due to significant level fluctuations, the ON/OFF frequency is high, leading to quick failures. - Cannot be used in a pressurized tank. - Fine powders invade the sealing area, causing malfunction. - Want to detect light powders, but need to increase the size of the blades, making it difficult to use. - Cannot determine the state inside the tank, making it unclear how the blades are moving. - Have previously broken it by incorrectly applying the power supply voltage. ■ Issues with using a capacitive level switch - Sensitivity adjustment is cumbersome. - Uncertainty about the physical properties of the measured substance leads to difficulties in sensitivity adjustment. - The measured substance undergoes physical changes, such as moisture variation, causing malfunctions. - Used for detecting resin powder, but adhesion makes sensitivity adjustment tricky and difficult. ■ Issues with using a vibrating level switch - Adhesion prevents vibration recovery during empty conditions. - The vibrating rod may break due to overload. - Used for detecting chute blockages, but has a short lifespan. - Cannot be used at high temperatures of 200°C. In this way, the pendulum-type level switch overcomes conditions that were difficult to measure with other types of level switches and provides stable detection.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationWith the adoption of a super high-sensitivity detection circuit, it has become possible to detect the flow of insulating powders and low-density powders, which were previously difficult to detect. It can be used for flow detection and clog prediction of powders and particles flowing through pipes. Additionally, it can penetrate materials such as glass and synthetic resins, allowing for indirect detection, making it optimal for powder flow in various industries. The KFD-1 type is a flow switch, but there are also continuous output KFD-2 types and contact-type flow sensors like the KDS-1 type. For more details, please refer to the PDF materials or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationIf you want to measure the flow rate of a waterway, using an electromagnetic flowmeter or ultrasonic type requires the installation of a weir or a separate flow velocity meter. However, with the "Open Channel Flow Meter AVFM 6.1," you can install it without extensive construction, and it allows simultaneous measurement of flow rate and water level with just one sensor. <Features of AVFM 6.1> - Simultaneous measurement of flow velocity from 0.03 to 6.2 m/sec and water level from 25.4 mm to 4.57 m with a single unit. - Simply fix the sensor to the bottom of the waterway with a bracket and input the information into the controller to start measuring. - Large-capacity data logger with 6.5 million points. There is also a portable type available, "Stingray 2.0." *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe KVX and XV2 models are compact, small vibrating level switches that pursue ease of use while maintaining the performance of our vibrating level switch KVK model. - Despite their small size, they can stably detect low-density powders with a specific gravity of 0.1 or higher (optional 0.03 or higher), making them suitable for use with resin pellets, powders, flakes, and more! - The installation sizes are also small diameter. The KVX model is for R1 installation type, and the XV2 model is for R(G) 3/4 installation type. Flange and hygienic installation options are also available! - No initial adjustment is required. Just like the KVK model, measurement starts immediately upon powering on! - There is no influence from changes in the physical properties of the measured substance, such as dielectric constant! Options for vibrating rod with mountain shape and vibrating pulse specifications are also available! - Amplified separation types that are effective for tanks with vibrations, such as knockers, can also be manufactured! - If there is adhesion on the detection rod, the optional pulse transmission specification is recommended! *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationLeak Alert 73 (integrated type) / 65-02 (separated type) is an electrodynamic dust monitor. The electrodynamic type is a high-resolution and high-stability dust monitor (particulate concentration meter) that is less affected by dust adhesion to the probe compared to conventional triboelectric methods or traditional optical detection methods. Generally, during filter cleaning (pulse jet, shaking, backwashing), the exhaust concentration of a typical bag filter temporarily increases. If there is an abnormality in the filter, a rapid concentration increase occurs. By monitoring this rapid concentration increase with a dust monitor (particulate concentration meter), it is possible to detect abnormalities in the filter at an early stage and replace the filter before it completely tears. Additionally, it is possible to identify filters that are experiencing abnormalities from trends, which can help reduce running costs. We can assist with explanations of the dust monitor, selection of sensors suitable for usage conditions, and we also offer test product loans, so please feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe horizontal float switch is a sensor that detects liquid level by utilizing the buoyancy of a float. Its operating principle involves the ON-OFF switching of contact output through the mutual magnetic action between a magnet attached to the end of the float and a magnet inside a case separated by a partition. In addition to the standard KF-207 model, we also offer custom-made options tailored to the measuring liquid and conditions. - For stable measurement of high-viscosity liquids or liquids containing impurities, we have the KF-207F model, which is mounted vertically. - If the liquid contains fine solids, such as sewage or scum, which may prevent the float from moving, we offer the KF-209 model with a bellows. - For use in ships where chattering needs to be prevented, we provide the KF-207K model with a larger float size (φ40-200L). Additionally, we manufacture level switches suitable for various applications, including explosion-proof specifications, heat-resistant specifications, screw-mounted specifications, models with operational test levers, two-contact output specifications, and products certified by NK. If you have any concerns regarding liquid level measurement, please feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe ball float we handle, the 【KARI Float Switch】, has a weight embedded inside the float that tilts in one direction and a micro switch. Additionally, there is a pendulum-like weight that presses the micro switch when the float tilts, allowing it to output contacts in response to the tilt of the float. There are two types of buoyancy: 2N and 6N. The 2N KARI Mini Float is suitable for level control (for alarms) in clean water, while the 6N buoyancy KARI Float can handle wastewater containing solid particles. Furthermore, we also offer a multi-point ball float switch model KF-805N, which combines the KARI Mini Float with a terminal box, allowing measurements from one to six points (with optional seven or eight points). For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationSince the detection electrode is always in contact with the measurement object, it can reliably measure under challenging conditions such as measurements during input, measurements in dusty environments, and measurements of materials with low dielectric constants, which are difficult for non-contact methods. 【Features】 - No moving parts, making maintenance easy - Capable of handling high-temperature, high-pressure, strong acid, strong alkali, conductive, and insulating conditions - Long-length measurements can be safely accommodated due to robust electrode design - Suitable for use in explosion-proof areas with intrinsically safe explosion-proof types - Can be sold together with an indicator (optional) *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe rotary level switch that we have been manufacturing since the founding of our company responds to user needs thanks to our years of technical expertise. For example, if you cannot determine the operating status of the rotary level switch from a distance, options such as a rotation confirmation plate or an operation indicator light are available. If the inner diameter of the mounting hole for the tank is smaller than the size of the vane, and it is not possible to remove the vane to install the level switch and then reattach the vane, an option for an expandable vane is available. The expandable vane can be installed in the tank while the vane is still attached. Moreover, due to its larger surface area, it is effective even for lightweight powders! The above is just one example. If you have any concerns regarding powder measurement, please feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationAlthough it is contact-based, it can be used in many applications such as "screw conveyors," "belt conveyors," "drying equipment conveyors," and "tank bottoms," and it is very helpful for production processes and product quality control. --Features-- - Usable for various powders and granules - Capable of measuring not only surface moisture but also internal moisture - Not affected by flow rate or color changes of the measured material - Usable in various applications *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationIt can be used in drainage treatment facilities, water purification equipment, power plants (desulfurization units), as well as in petrochemical and refining sludge tanks. By accurately monitoring the sludge level, equipment such as pumps can be operated efficiently, leading to energy savings. - Measurement range: Max. 10m - Sensor materials can be selected between stainless steel and Teflon according to measurement conditions - Maintenance of the sensor part is reduced by the cleaning unit - Standard equipped with a data logger of 10,000 points - A portable type that allows easy measurement at multiple locations is also available *For more details, please refer to the PDF materials or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationUnlike the Doppler method, it detects only the area around the electrodes, allowing for pinpoint detection without being affected by nearby rotating bodies or similar influences. It can be used for contamination prevention and quality control of mixed products through leak detection from bag filters and cyclones, clog detection, and flow/no-flow detection in air transport routes. Main features of the KDS-1 model: - As it is a contact type, it can measure low concentrations without being affected by changes in flow rate! - It has no moving parts, maintaining high functionality with minimal maintenance! - Alarm delay time can be set to prevent malfunctions! - Compact integrated design makes handling and adjustments easy! * The KDS-1 model is a contact type flow sensor, but there is also the KFD-1 model that detects flow non-contact. For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThere are float-type level gauges for measuring liquids, but the electrode type allows customers to easily set the detection position by cutting or connecting the electrodes. If the liquid is conductive, there is a wide variety of electrode materials available, making it possible to measure even high concentrations of acids and alkalis. You can specify the use of coated tubes such as PVC or Teflon for the electrodes, so there is no concern about conductivity due to liquid pooling. Additionally, there are electrode types available that can be used under high temperature and high pressure conditions, which are typically difficult to measure with standard types, so please feel free to contact our sales office for inquiries. The main features of the electrode type level switch are as follows: - Multi-point detection possible with a single unit - Choice of electrode rod material and thickness - Detection points can be changed simply by adding or cutting the electrode rods - Pressure-resistant specifications available (optional)
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationAround the conveyor, we ensure safety near the conveyor with the following equipment we handle: - Emergency stop devices (emergency pull cord switches) mandated by labor safety and health regulations [Our model numbers: KP-850-1, KP-850-2, KP-860, KP-870] - Off-center alarm switches that directly detect misalignment and wandering of the belt conveyor [Our model number: KP-880] - Speed detectors that detect the inability of the conveyor belt to move (slip) due to excessive loading [Our model numbers: KPS-11, KPS-21, KPS-123/124] In addition, we offer flow switches for detecting the flow of powders, granules, and bulk materials (KP-810, KP-820, KP-830, KP-4, KP-840, KFD-1), tilt switches (TC-3) capable of detecting chute level and chute blockages, leak-type level switches (KEL-2), and microwave-type level switches (MWS2-24TN/RN). *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe measurement method is a simple mechanical detection method, so it is not affected by dust and other factors that can cause malfunctions in non-contact continuous level gauges. Additionally, initial adjustments are easy; once the instrument is installed and powered on, measurement can begin immediately. With regular inspections and replacement of consumable parts, it can be used for many years. Our technicians can also be dispatched to inspect the instruments. *For more details, please refer to the PDF materials or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationFor example, if you want to measure the waste in a garbage pit, have you ever encountered issues such as, "The specific gravity of the waste (for example, paper waste) is light when it is in a rotating state, causing the blades to not stop, and it could not be detected..." or "The detection unit inside the pit was damaged by falling objects..."? Our microwave level switch model MWS can detect the measurement object even if its size is not uniform, as it receives microwaves emitted from the transmitter and detects when the measurement object interrupts the signal. (It does not respond to objects that are falling.) Additionally, it can measure with minimal influence from adhesion to the emitting surface or dust. If you are particularly concerned about adhesion to the emitting surface, measurement is possible even through a detection window (such as glass, Teflon, or ceramic, which allows radio waves to pass through). *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe compact rotary level switch "KMS" is a palm-sized rotary level switch suitable for small tanks, completely renewing our conventional lineup and now available in a DC24V specification. It also complies with CE standards. 【Specifications】 - KMS (Standard Type) - KMS (Standard Stainless Steel Contact Type) - KMS-S (Protection Tube Extension Type L=150/200/250/300mm) - KMS-H (Heat Resistant Type Max. 200℃) 【Options】 - "Deployable Blade" that eliminates the hassle of attaching blades during tank installation - Operation Indicator LED *Our company will be exhibiting at POWTEX 2024, the 25th International Powder Technology Exhibition Tokyo, held at Tokyo Big Sight from November 27 (Wednesday) to November 29 (Friday). We sincerely look forward to your visit. *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationCustom-Made Delivery Record No. 1 1. High-sensitivity electrodes can be used for materials with low dielectric constant. 2. Coated electrodes can be used for corrosive materials. 3. Automatic correction function is standard, allowing for use with viscous materials like honey. 4. Flat electrodes can be used when there are concerns about load detection at lower limits or when stirring prevents the electrodes from being placed inside the tank. 5. Wire electrodes can be used for measuring the angle of repose. 6. Pipeline electrodes can be used for flow detection within pipes. 7. Heat-resistant electrodes can be used in locations with temperature. 8. For use in areas with vibrations from knockers or vibrators, amplifier-separated types can be used. 9. If installation space is limited, amplifier-separated cable direct output specifications can be accommodated. 10. Installation and materials can be tailored to the measurement object and your preferences. In addition to the above, we will select models suited to your usage locations. We also accommodate measurements for high-difficulty applications, so please feel free to consult with us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationDifferences from paddle type! 1. An amplifier composed of electronic components instead of a motor. 2. Long lifespan due to the absence of mechanical wear parts such as gears and clutches. 3. Universal power supply from AC 100V to 240V. 4. Complete separation of the detection part and the power part by a partition, so even if the detection vane is overloaded, it does not affect the power part. 5. The partition prevents fine powder from entering the sealing part due to pressurization. 6. Powders with a specific gravity of 0.1 or more can be measured, and detection torque adjustment is also possible. 7. Less susceptible to adhesion due to instantaneous movement. 8. The driving torque remains constant even when the detection vane is buried, ensuring stable operation during empty return. Our original SWM series products, developed and manufactured with years of experience and technology, come in various variations suitable for different applications. For more details, please refer to the PDF materials or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThis booklet provides an easy-to-understand explanation of the multi-hop wireless system "Kunimaru" through manga. We respond to the real voices from manufacturing sites, such as "We want to introduce a level meter and manage it all at once, but the tanks are far away, so wiring work is necessary." Please feel free to download and take a look. 【Contents】 ■ Multi-hop wireless "Kunimaru" ・ Wireless * For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThis booklet provides an easy-to-understand explanation of the multi-point ball float switch 'KF-805N' in a comic format. "I want to measure the liquid level in a tank, but there are many solids in the liquid... Is there a level switch that works even in such a tank?" We respond to the real voices from manufacturing sites. Please download and take a look. [Contents] ■ Multi-point ball float switch 'KF-805N' ・ Solids in the liquid * For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThis booklet provides an easy-to-understand explanation of the open channel flow meter "AVFM6.1" through manga. It addresses the real voices from manufacturing sites, such as "I want to measure the flow in the channel, but with microwave or ultrasonic types, I have to set up a weir or install a separate flow velocity meter, which is cumbersome." Please feel free to download and take a look. 【Contents】 ■ Open Channel Flow Meter "AVFM6.1" ・ Two functions in one unit *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThis booklet provides an easy-to-understand explanation of backscatter dust monitors through manga. "We want to measure dust concentration in a 10m class duct, but isn't it difficult because optical sensors need to be installed facing each other?" This addresses the real voices from manufacturing sites. Please feel free to download and take a look. [Contents] ■ Backscatter Dust Monitor ・ Maintenance *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThis booklet provides an easy-to-understand explanation of electrode-type level switches through manga. We respond to real voices from manufacturing sites, such as, "I want to measure the liquid level in the tank, but since there may be a possibility of changing the measurement point, is there a product that allows for easy changes to the measurement point?" With an electrode-type level switch, you can easily make changes. Please download and take a look. 【Contents】 ■ Electrode-type Level Switch ・ Easy to set up *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThis booklet provides an easy-to-understand explanation of sounding-type level meters through manga. We respond to real voices from manufacturing sites, such as, "In powder silos, non-contact level meters malfunction due to dust; are there any other models that can measure accurately?" Please feel free to download and take a look. [Contents] ■ Sounding-type level meters ・ Mechanical *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThis booklet provides an easy-to-understand explanation of ultrasonic underwater sludge level meters through manga. "We manually measure the sludge levels in multiple septic tanks every time we go to the site, but is there a sensor that can measure in real-time without having to go on-site?" This is a real voice from the manufacturing field that we address. Please feel free to download and take a look. [Contents] ■ Ultrasonic Underwater Sludge Level Meter ・ Energy-saving *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThis booklet provides an easy-to-understand explanation of non-contact detection using microwave level switches through manga. It addresses real voices from manufacturing sites, such as "We are measuring the level of waste in the pit with a rotary method, but it's not working well." Please feel free to download and take a look. 【Contents】 ■ Microwave Level Switch ・ Non-contact Detection *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThis booklet provides an easy-to-understand explanation of flow detection using microwave flow sensors through manga. "We had a hard time because the supply line to the raw material tank was clogged, and we couldn't store the raw materials. Is there anything that can monitor the flow of raw materials in the transport line?" This addresses the real voices from the manufacturing site. Please feel free to download and take a look. [Contents] ■ Microwave Flow Sensor ・ Flow Detection *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThis booklet provides an easy-to-understand explanation of the convenience of vertical float switches through manga. We respond to real voices from manufacturing sites, such as "I want to automatically control the liquid level in a storage tank, but is there a good model available?" With vertical float switches, you can set the number of contacts and detection points as needed, allowing for various liquid level control options. Please download and take a look. [Contents] ■ Vertical Float Switch ・ Convenience *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThis booklet provides an easy-to-understand explanation of radar level meters through manga. We respond to real voices from manufacturing sites, such as "I want to measure the raw materials in the cement silo using a non-contact level meter! Are there any good models available?" Please feel free to download and take a look. [Contents] ■ Radar Level Meters ・ Dust *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe installation of emergency stop devices on conveyor belts is legally required to ensure the safety of workers. This booklet provides an easy-to-understand explanation of emergency pull cord switches through manga. Please feel free to download and take a look. [Contents] ■ Emergency Pull Cord Switch ・ Safety *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration