1~45 item / All 153 items
Displayed results
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationContact this company
Contact Us Online1~45 item / All 153 items
PBS860/880 is an analog output transmitter for atmospheric pressure measurement. By adopting a piezoresistive element, it enables extremely high precision and stable measurement of atmospheric pressure. It also excels in long-term reproducibility, has low hysteresis, and maintains stable performance against temperature changes. Depending on the model, it converts to a linear analog output of voltage or current. It is also equipped with a potentiometer for offset (zero) adjustment. ▲ Supply voltage DC 8–35V, current consumption <4mA ▲ Suitable for battery and solar panel power applications, with analog output options of 4–20mA, 0–1/0–5/0–10/1–5V.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration■ Microprocessor-controlled temperature and humidity transmitter ■ Despite its probe shape, it has a built-in amplifier, and temperature input can be scaled to the output ■ HD9008TRR has an output of 4-20mA, while HD9009TRR has an output of 0-1V ■ The sensor is mounted at the tip of a cylindrical resin case, with a highly responsive and long-lasting capacitive type humidity sensor, and a platinum sensor (100Ω/0℃) for temperature ■ Calibration and scaling of the transmitter are all set via key operations. No soldering of jumpers or adjustment of potentiometers is required ■ The humidity sensor can be recalibrated using two types of saturants: 75% and 33% ■ The relationship between input and output is fixed. An output of 4mA (or DC0V) corresponds to 0% RH, and an output of 20mA (or DC1V) corresponds to 100% RH ■ The standard temperature setting for both HD9008TRR and HD9009TRR is -40 to +80℃, corresponding to outputs of 4-20mA and DC0-1V respectively ▼ All output models have a built-in amplifier ▼ Highly reliable humidity and temperature sensors ▼ Temperature output scaling available ▼ Outdoor protective shield (optional)
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration■The UVA radiometer LPUVA02 series measures the broadband UVA irradiance (W/m²) incident on a surface. ■The measured irradiance is the sum of direct solar radiation and scattered radiation. ■The LPUVA02 can also measure UVA irradiance indoors in closed environments. ▲High sensitivity μV, DC 4-20mA, 0-1V output, level gauge, with shielding plate.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationpH transmitter that converts the output from a pH electrode or Redox electrode into a temperature-compensated 4-20mA analog signal, insulated from the electrode's input circuit. The LCD display can show the process signal values and various parameters. High-quality product design and the use of selected components enable long-term, high-precision, and reliable measurements. It can be used in combination with separately sold pH electrodes or Redox electrodes and a temperature probe (Pt100Ω/0°C). ▼ DC 4-20mA output pH meter ▼ Relay output (delay setting available)
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe HD2021T series converts light and radiation amounts in the UVB and UVC spectral regions and the wavelength range of 400 to 1050 nm into signals of 0-10V or 4-20mA, represented as illuminance (lux), luminance, equivalent light curtain luminance (cd/m²), or irradiance (W/m²). These analog outputs are calibrated to the specified full-scale values before shipment. ▼ Analog output DC 4-20mA or DC 0-10V ▼ Three types of output scaling available ▼ Suitable for outdoor use (IP66 model) ▼ Equivalent light curtain luminance measurement (HD2021T7)
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe HD9817T series is a relative humidity and temperature transmitter that can be used in various applications such as HVAC-R, environmental monitoring, chemical storage, food transportation, greenhouse automation, and more. It is housed in an AISI304 stainless steel casing with an IP65 protection rating, making it suitable for use in harsh environmental conditions. Additionally, its ultra-compact size (φ14×138mm) and two output types (0-1V analog output, RS232C output) make it ideal for integration into various host devices. The HD9817T series allows for reading measurements and calibrating the relative humidity sensor using the HD9817TC software (available for download from this site). ▼ High-precision capacitive sensor, Pt100 sensor with accuracy class 1/3DIN ▼ Output options include 0-1V and RS232C ▼ Durable AISI304 stainless steel housing ▼ Compact size of φ14×138mm, perfect for embedded applications
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration- Outputs 5 elements with different measurement ranges as analog voltage or current (standard) - Outputs an additional 12 elements with different measurement ranges as analog voltage or current (via optional extended analog output) - Five types of communication interfaces: RS232C, RS422, RS485 Modbus-RTU, RS485 multi-drop, and AoXnd mode for extended analog output - Averaging interval for all output values can be arbitrarily set from 1 to 60 seconds or 1 to 60 minutes - Achieves measurement accuracy of ±1% for wind direction and speed measurements through raw data processing and evaluation algorithms - 50Hz data output via high-speed digital sampling mode, or high-speed analog data sampling at 5Hz and 20Hz - Orientation adjustment to magnetic north using an integrated compass - No moving parts, significantly reducing maintenance and service costs - Robust and reliable structure suitable for long-term use in harsh environmental conditions - Heater function option: The built-in heater function prevents icing and snow accumulation on the ultrasonic sensor, ensuring high-precision measurements - Optional full-duplex 4-wire output for RS422 communication
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe output from the pH electrode or Redox electrode is temperature-compensated and converted into an insulated 4-20mA analog signal from the electrode input circuit. The analog output is single-point, allowing for the selection of either pH or Redox output, and scaling is also possible. In addition to the analog output, it features two relay outputs with a delay setting of up to 255 seconds. The large LCD on the front displays temperature on the top line and either pH or Redox values on the bottom line, showing the set parameters during configuration. The DO9765TR and DO9785TR enable high-precision and reliable measurements over an extended period due to high-quality product design and the use of carefully selected components. They are used in combination with separately sold pH electrodes or Redox electrodes and a temperature probe (Pt100Ω/0℃). ▼ DC 4-20mA output pH meter ▼ Relay output (delay setting available)
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe conductivity transmitters DO9766T-R1 (wall-mounted type) and DO9786T-R1 (panel-mounted type) correct the output of the conductivity electrode for temperature and convert it into an insulated 4-20mA analog signal from the input circuit of the electrode, with scaling capabilities. In addition to the analog output, they are equipped with two relay outputs that can be set with a delay of up to 250 seconds. The large LCD on the front displays the process measurement values under normal conditions and the set parameters during configuration. Thanks to high-quality product design and the use of carefully selected components, they enable long-term, high-precision, and reliable measurements. They are used in combination with separately sold conductivity electrodes and temperature probes (Pt100Ω/0℃). ▼ DC4-20mA output conductivity meter ▼ Relay output (delay setting available)
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration■Analog + RS232C/RS485 Output The HD2001 series measures and displays temperature, relative humidity, and atmospheric pressure, depending on the model. Additionally, the HD2001.2 can measure and display wind speed using a thermal wire probe equipped on the top of the unit. All models are equipped with RS232C or RS485 serial output, allowing for networking of multiple units. Furthermore, all models feature an open collector alarm output with configurable upper and lower limits. The HD2001.1 has an analog output that can be changed in addition to digital output, and the selection of output type can be easily done by switching dip switches and jumpers on the internal circuit board. The large dual-line LCD common to all models displays one of the environmental monitoring elements on the upper line and continuously shows temperature changes on the lower line. *Models HD2001.1: Temperature, Humidity, Atmospheric Pressure HD2001.2: Temperature, Humidity, Atmospheric Pressure, Wind Speed
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration- Measurement resolution is available in standard 0.2mm, as well as 0.1mm and 0.5mm. - An integrated bubble level assists in accurate installation. - Corrosion-resistant materials provide excellent long-term reliability. - In the heater-equipped version, the heater automatically operates around +4°C during low environmental temperatures, snowfall, or after snowfall to eliminate residual snow and ice, enabling high-precision measurements. - Power supply voltage is DC24V (HD2013R) or DC12V (HD2013R1), with a power consumption of approximately 165W. - A collection cone connected to an aluminum cylinder directs rainwater into the measuring container. → When the specified level is reached, the accurately calibrated container rotates under its own weight to drain the rainwater. → During the rotation of the container, a normally closed reed contact opens momentarily, sending a pulse signal to the counter. → Rainfall is measured based on the number of times the container rotates and empties. - The number of pulse signals can be detected and recorded by data loggers or pulse counters like the HD2013-DB. - By combining with the wireless data logger HD33 series, which has a built-in communication modem, measurement data can be directly uploaded to the cloud, allowing for monitoring of rainfall information.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration■The capacitance value of the sensing element changes in response to the wet sensing surface caused by raindrops. ■The built-in heater evaporates moisture from the rain sensor to maintain dryness and prevent false signals (malfunctions) caused by mist or dew. ■At low temperatures, this heater melts snow and detects snowfall using the ambient temperature sensor. ■The circular dome on the outside of the rain gauge serves as a windbreak to prevent sensor malfunctions. ■Equipped with an automatic calibration algorithm to correct fluctuations (drift) in response caused by dirt accumulating on the sensor's sensing surface. ■Features RS485 digital output that can be used with Modbus-RTU or proprietary protocol, 0/4–20mA or 0–10V analog output, and a voltage-free contact output. ■Protection rating IP68. ■A bracket for mounting on walls or poles with a diameter of 30–50mm is included as standard. ■Bird deterrent spikes are optional. ▲Built-in heater accurately detects rain, snow, hail, and sleet. ▲Compact size of φ70×70mm, high durability, protection rating IP68. ▲Operating temperature -40 to +60℃, bird deterrent spikes (optional). ▲Drift correction due to dirt is achieved through a self-calibration algorithm. ▲RS485 (Modbus-RTU or proprietary protocol) / Analog / Contact output.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration■Atmospheric pressure transmitter that measures gauge pressure or gauge differential pressure in the range of 10hPa to 200hPa and converts it to an analog output of current or voltage. ■Suitable for any application involving non-corrosive air or gas. ■Enables extremely high accuracy and stability in atmospheric pressure measurement thanks to the built-in piezoresistive sensor. It exhibits low hysteresis and excellent performance in reproducibility and temperature characteristics. ■All models are factory calibrated for accuracy before shipment, allowing for immediate installation and use. ▼Two types of output: 4-20mA (HD408T) / 0-10V (HD4V8T) ▼For gauge micro-pressure/micro-differential pressure monitoring in the measurement range of 10hPa to 200hPa ▼Extremely high measurement accuracy and long-term stability with piezoresistive sensor ▼Low hysteresis with excellent measurement reproducibility and temperature characteristics ▼Compact size (66×60×35mm) allows for installation in narrow spaces
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationMain Features: - Records data for temperature or relative humidity, temperature, and dew point - Built-in sensor, body-fixed type, or cable-connected separate probe - Manual (with delay time setting possible) or automatic logging start at a pre-programmed date and time - Configurable measurement value alarms with thresholds - USB output - Automatic log issuance in PDF and CSV formats - Software included for settings, monitoring, and data download - Software option compliant with FDA 21 CFR Part 11 - LCD display and LED indicators for power, data logging, and alarm status - Long-life lithium battery - Excellent environmental resistance ▲ Large memory capacity of 526,000 data points (capable of long-term recording for over 5 years with 1 element at 5-minute intervals) ▲ Three types of probes (body-fixed/separate/built-in) for a wide range of applications ▲ Ability to start/stop logging and set alarm thresholds ▲ Data download and management via included software ▲ Calibration certificate available from ACCREDIA (equivalent to IAJapan) ▲ Easy-to-install wall-mounted design
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe radiation balance meter LPNET07 measures the radiation balance received on its sensing surface from near ultraviolet to far infrared. The radiation balance is defined as the difference between the radiation incident on the upper surface of the radiation balance meter and that incident on the lower surface. The upward-facing surface measures direct solar radiation, diffuse solar radiation, and long-wave radiation emitted from the sky (clouds), while the downward-facing surface measures solar radiation reflected from the ground (albedo) in addition to long-wave radiation emitted from the Earth. The LPNET07 is designed with a robust structure to be used outdoors under any weather conditions and has high reliability for long-term measurements. In addition to its use for energy balance measurements in meteorology, the LPNET07 can also be used for measuring indoor radiation temperature (ISO7726). ▼ High-precision measurement of radiation balance in the spectral range from near infrared to far infrared ▼ High sensitivity output of 10μV/(W/m²) (typical value) ▼ Robust housing design that withstands harsh environmental conditions ▼ Usable for measuring indoor radiation temperature as well as outdoor (ISO7726) ▼ Signal amplifier converter (optional) to convert microvolt output to standard signal is also available.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationTwo pyranometers equipped with thermopile sensors mounted back-to-back allow for measurements from two directions. The pyranometer directed upwards (towards the sky) measures the incident global solar radiation, while the other one is directed downwards (towards the ground) and measures the global solar radiation reflected from the ground. Three versions are available, fully compliant with ISO 9060:2018 standards and WMO (World Meteorological Organization) guidelines "Guide to Meteorological Instruments and Methods of Observation": Spectrally Flat Class A LPS110P0, Spectrally Flat Class B LPS050P0, Spectrally Flat Class C LPS060P0. All are passive types and do not require a power supply. The electrical signal output from the two pyranometers can be sent directly to data loggers or automatic data processors. They can be used outdoors in low-temperature environments, and the built-in bubble level allows for precise leveling during installation. ▲ High-quality measurement specifications due to lightweight body design ▲ Accuracy and reliability backed by ISO 17025 accredited lab (equivalent to JCSS) ▲ High immunity to interference in installation environments, no power supply required
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe LPPHOT02 series illuminance meter measures illuminance (lux), defined as the ratio of luminous flux (lumens) incident on a surface to unit area (m²). The spectral response curve of the photometric measurement probe approximates the human eye's response curve, known as the standard photopic curve V(λ). The difference between the LPPHOT02 series and the standard photopic curve V(λ) in spectral response is calculated as error f’₁. The LPPHOT02 series illuminance meter has a robust structure, designed for long-term outdoor use, and is primarily used for meteorological measurements in daylight.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration■High-precision measurement of the temperature of the target using RTD sensors or thermocouples for immersion, penetration, surface, or air probes. ■Input B can connect a 4-wire Pt100 sensor or a 2-wire or 4-wire Pt1000 sensor. ■Input A can connect K, J, T, N, or E thermocouples. ■Probes connected to Input B use an 8-pin DIN45326 connector with an automatic recognition module (SICRAM) that stores calibration data from the factory, while Input A is equipped with a mini connector for thermocouples. ■The HD2178.2 can store up to 36,000 measurement data points as a data logger. Stored data can be transmitted to a PC via RS232C and USB2.0. The data storage interval, print content, and baud rate can be set via the menu. ■The HD2178.1 and HD2178.2 are equipped with an RS232C serial port, allowing real-time transmission of measurement data to a PC or portable printer. ■The MAX-MIN-AVG function displays the maximum, minimum, and average values over any specified time period. ■Equipped with a REL (deviation measurement) function that displays the deviation (positive or negative value) based on the measurement at any moment, a HOLD function, and a cancelable auto power-off function. ■Protection rating IP66.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationHigh-precision temperature measurement of the target using immersion, penetration, surface, or air probes with Pt100 or Pt1000 sensors. Three-wire or four-wire Pt100 sensors and two-wire Pt1000 sensors can be used. The thermometer's resolution is 0.01°C in the range of ±199.99°C and 0.1°C in other ranges. The temperature probe is equipped with an automatic recognition module (SICRAM) that memorizes the calibration details from the factory. The HD2107.2 can store up to 80,000 measurement data points as a data logger, and the stored data can be transmitted to a PC via RS232C and USB2.0. The data storage interval, print content, and baud rate can be set via the menu. The MAX-MIN-AVG function displays the maximum, minimum, and average values over any specified time. Other features include the REL (deviation measurement) function that displays the deviation (positive or negative value) based on the measurement at any moment, a HOLD function, and a user-definable auto power-off function. The main unit is protected to IP66 even when the probe is connected. ▼Measurement resolution 0.01°C ▼Pt100/Pt1000 sensors ▼REL (deviation measurement)
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration■ It can measure temperature with high precision of ±0.01℃ on 2 channels. ■ Compatible with 3-wire or 4-wire Pt100/Pt1000/Ni1000 and NTC thermistors. ■ Real-time measurement is possible via RS232C serial communication. ■ The HD2127.2 can store up to 32,000 sets of measurement data as a data logger, and the stored data can be sent to a PC via RS232C and USB2.0. ■ The A-B function calculates and displays the temperature difference measured by inputs A and B. It also has functions such as REL (deviation measurement), which displays the deviation (+ or - value) based on the measurement value at any moment as a reference value. ■ The protection rating is IP67 (waterproof specification). ▼ Measurement instrument resolution 0.01℃ ▼ Pt100/Pt1000 sensor ▼ REL (deviation measurement)
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration■High-precision measurement of the temperature of the object using immersion, penetration, surface, or air probes with Pt100 or Pt1000 sensors ■Compatible with 3-wire or 4-wire Pt100 and Pt1000 sensors ■MAX-MIN-AVG function displays the maximum, minimum, and average values over any specified time ■REL (deviation measurement) function displays the deviation (positive or negative value) based on the measurement at any moment ■HOLD function and a cancelable auto power-off feature ■Protection rating is IP67 (waterproof) ■Large LCD display
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration■High-precision temperature measurement of the target using immersion, penetration, air, or surface probes ■Connect thermocouples K, J, T, N, R, S, B, or E ■The HD2128.2 can store up to 76,000 sets of measurement data as a data logger. Stored data can be transmitted to a PC via RS232C and USB2.0. The data storage interval, print content, and baud rate can be set via the menu. ■Equipped with an RS232C serial port to transmit measurement data in real-time to a PC or portable printer ■The MAX-MIN-AVG function displays the maximum, minimum, and average values over any specified time ■Equipped with a REL (deviation measurement) function that displays the deviation (positive or negative value) based on the measurement at any moment, a HOLD function, and a user-definable auto power-off feature ■Protection rating IP66 ▲1 thermocouple input / A-B2 inputs ▲Differential temperature display for A-B2 inputs ▲Large-capacity data logger function ▲MAX-MIN-AVG, deviation measurement
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration■High-precision temperature measurement of the target using immersion, penetration, or air/surface probes ■Connects K, J, T, or E thermocouples ■Displays maximum, minimum, and average values over any specified time with MAX-MIN-AVG function ■A-B function calculates and displays the temperature difference measured by inputs A and B ■Equipped with REL (deviation measurement) function that shows the deviation (positive or negative value) based on the measurement at any moment, HOLD function, and a user-releasable auto power-off feature ■The protection rating of the main unit is IP67 ▲ Thermocouple A-B2 input ▲ Differential temperature display for A-B2 input ▲ Large LCD display ▲ MAX-MIN-AVG, deviation measurement
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration● Measures relative humidity and temperature using a humidity-temperature composite probe with a Pt100 sensor ● Allows for standalone temperature measurement using immersion, penetration, or surface probes ● Can use Pt100 or Pt1000 as temperature sensors ● Connects a humidity-temperature composite probe to calculate and display not only relative humidity and temperature but also absolute humidity, dew point, water vapor pressure, and discomfort index ● Equipped with an automatic detection module (SICRAM) that stores calibration data from the factory ● Features an RS232C serial port to transmit measurement data in real-time to a PC or portable printer ● Displays maximum, minimum, and average values over any specified time period using MAX-MIN-AVG function ● The HD2101.2 can save up to 38,000 measurement data points as a data logger, with saved data transmitted to a PC via RS232C and USB2.0. Data saving intervals, print content, and baud rate can be set via the menu ● Equipped with REL (deviation measurement) function to display deviations (positive or negative values) based on measurements at any moment, HOLD function, and a user-definable auto power-off feature ● Protection rating IP66
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration■Pressure measurements are conducted using the TP704 and TP705 series pressure probes and the SICRAM module PP471. ■Temperature is measured using a Pt100 sensor probe or a 4-wire Pt100 sensor. ■The temperature probe is equipped with a module (SICRAM) that memorizes the calibration details from the factory, and when the power to the pressure and temperature meter is turned on, it automatically detects the stored information. ■The data logger type (HD2124.2) can store up to 32,000 sets of measurement data, and the stored data can be transmitted to a PC via RS232C and USB2.0. ■The data storage interval, print content, and baud rate can be set via the menu. ■The MAX-MIN-AVG function displays the maximum, minimum, and average values within any specified time. ■The Peak function detects the peak value of the pressure. ■The A-B function displays the difference between inputs A and B. ▲A-B2 input, temperature measurement is also possible. ▲Absolute pressure, gauge pressure, and differential pressure measurements. ▲Large-capacity data logger function. ▲MAX-MIN-AVG and deviation measurements.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration■Pressure measurements are conducted using the TP704 and TP705 series pressure probes and the SICRAM module PP471. ■Temperature is measured using immersion/penetration/surface or air Pt100 sensor probes, or a 4-wire Pt100 sensor. ■The temperature probe is equipped with a module (SICRAM) that stores calibration data from the factory, and when the power to the pressure and temperature meter is turned on, it automatically detects the saved information. ■The MAX-MIN-AVG function displays the maximum, minimum, and average values over any specified time period. ■It features a REL (deviation measurement) function that displays the deviation (positive or negative value) based on the measurement at any moment as a reference value, a HOLD function, and a user-definable auto power-off function. ■Protection rating IP67. ▲Absolute pressure, gauge pressure, and differential pressure measurement. ▲Pt100 temperature sensor connection available. ▲Large LCD display. ▲MAX-MIN-AVG, deviation measurement.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration■Pressure is measured with a built-in differential pressure sensor. ■By connecting the PP471, which functions as an interface between the pressure gauge and pressure probes, a wide range of pressure measurements can be made with all TP704 and TP705 series pressure probes. ■The built-in pressure module of HD2114B.0 and HD2114B.2 measures atmospheric pressure. ■Temperature is measured using immersion/stabbing/surface/air Pt100 sensor probes, or 4-wire Pt100 sensors, or 2-wire or 4-wire Pt1000 sensor probes. ■The temperature probe with SICRAM module stores calibration information and automatically detects saved information upon powering on the pressure and temperature meter. ■Data logger types (HD2114.2, HD2134.2, HD2164.2, HD2114B.2) can store up to 36,000 sets of measurement data. The stored data can be transmitted to a PC via RS232C and USB2.0. ■The data storage interval, print content, and baud rate can be set via the menu. Measurement data can be transmitted in real-time to a PC or printer via the serial port. ▲Eight series with different pressure and temperature measurement ranges. ▲Large LCD display. ▲MAX-MIN-AVG and deviation measurement.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration■ Measures air velocity, flow rate, and temperature inside pipelines or vents using a hot wire or vane probe. ■ Capable of measuring only the temperature of the subject using immersion, penetration, or air probes. ■ Selectable temperature sensors are Pt100 or Pt1000. ■ Probes are equipped with a SICRAM module that memorizes calibration data from the factory. ■ Equipped with an RS232C serial port to transmit measurement data in real-time to a PC or portable printer. ■ Displays maximum, minimum, and average values over any specified time using the MAX-MIN-AVG function. ■ Features a REL (deviation measurement) function that displays deviations (positive or negative values) based on measurements at any moment, a HOLD function, and a user-definable auto power-off feature. ■ Protection rating IP66. ■ The HD2103.2 can store up to 38,000 measurement data points as a data logger, with saved data transmitted to a PC via RS232C and USB2.0. The data storage interval, print content, and baud rate can be set through the menu. ▲ Hot wire and vane probes ▲ Wind speed, flow, and temperature measurement ▲ Serial output and logger function ▲ MAX-MIN-AVG, deviation measurement
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration■ Measures air velocity, flow rate, and temperature inside pipelines or vents using hot wire or vane probes. ■ It is also possible to measure only the temperature of the target using immersion, penetration, or air probes. ■ Temperature sensors can be selected from Pt100 or Pt1000. ■ Probes are equipped with a SICRAM module that memorizes calibration data from the factory. ■ The MAX-MIN-AVG function displays the maximum, minimum, and average values over a specified time period. ■ Equipped with REL (deviation measurement) function that uses measurements at any moment as a reference value, HOLD function, and auto power-off function. ■ Protection rating IP67. ▲ Hot wire and vane probes ▲ Wind speed, flow, and temperature measurement ▲ Large LCD display ▲ MAX-MIN-AVG, deviation measurement
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration- Four variations are available depending on the presence of data logger functionality and measurement range. - The differential pressure detected by the Pitot tube connected to the manometer input is measured by the built-in micro-pressure sensor, allowing for the acquisition of wind speed and flow rate data inside pipelines and vents. - All K-type thermocouple sensors equipped with a standard thermocouple mini connector can be connected, enabling use as a K-type thermocouple thermometer. - The HD2114P.2 and HD2134P.2 can store up to 36,000 measurement data points as a data logger, and the stored data can be transmitted to a PC via RS232C and USB2.0. The data storage interval, print content, and baud rate can be set via the menu. - The MAX-MIN-AVG function displays the maximum, minimum, and average values over any specified time period. - Equipped with REL (deviation measurement) function, HOLD function, and auto power-off function, allowing measurement values at any moment to be used as reference values. - Protection rating IP66. ▼ Micro-pressure, micro-differential pressure, atmospheric pressure, and temperature measurement ▼ Built-in micro-pressure sensor ▼ Peak value detection function ▼ MAX-MIN-AVG, deviation measurement
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration■ Measurement of illuminance, luminance, PAR (photosynthetically active radiation), and radiance (spectral ranges of VIS-NIR, UVA, UVB, UVC, UVBC, or effective radiation according to the CIE UV action curve) is possible by selecting the appropriate probe. ■ All probes are equipped with an automatic recognition module (SICRAM) that memorizes the calibration details from the factory. ■ In addition to instantaneous measurements, the illuminance, luminance, and radiance meters calculate the time-integrated values of the obtained measurements. ■ The menu settings allow for the association of time-integrated measurement values and integration times, as well as threshold settings. ■ The HD2102.2 can function as a data logger, capable of storing up to 38,000 measurement data points for single-element probes and up to 14,000 for multi-element probes. The stored data can be transmitted to a PC via RS232C and USB2.0. ■ Data storage intervals, print content, and baud rates can be set via the menu. ■ Equipped with features such as RE (deviation measurement) based on any moment's measurement value, HOLD, and auto power-off. ■ Protection rating IP66. ▼ Illuminance, luminance, PAR, UVA, UVB, UVC, UVBC, illuminance + UVA, blue light, solar radiation ▼ Logging storage data: 38,000 ▼ MAX-MIN-AVG, deviation measurement
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration■ Measures illuminance, luminance, PAR (photosynthetically active radiation), and irradiance (in the spectral ranges of VIS-NIR, UVA, UVB, UVC, UVBC, or effective radiation according to the CIE UV action curve) based on the selected probe. ■ All probes are equipped with the automatic recognition module "SICRAM." ■ Automatically selects not only the type of connected probe but also the measurement units. ■ Displays maximum, minimum, and average values over any specified time using the MAX-MIN-AVG function. ■ Equipped with a REL (deviation measurement) function that displays deviations (positive or negative values) based on measurements at any moment, a HOLD function, and a user-releasable auto power-off feature. ■ Features a rubber exterior on the main body perimeter and connector area. ■ Protection rating IP67. ▼ Illuminance, luminance, PAR, UVA, UVB, UVC, UVBC, illuminance + UVA, blue light, solar radiation. ▼ MAX-MIN-AVG, deviation measurement. ▼ Large LCD display.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration■Temperature measurement is possible using immersion, penetration, and surface probes of Pt100 or Pt1000. ■Electrode calibration can be performed at 1, 2, or 3 points, and during the calibration process, appropriate values can be selected from 13 standard liquid values. ■The temperature probe is equipped with an automatic recognition module "SICRAM," which can automatically select the type of connected probe and measurement unit. Calibration details are also stored. ■The HD2105.2 can function as a data logger, capable of storing up to 34,000 pH and temperature measurement data, which can be transmitted to a PC via RS232C and USB2.0. The data storage interval, print content, and baud rate can be set through the menu. ■Equipped with an RS232C serial port to transmit measurement data in real-time to a PC or printer. ■The MAX-MIN-AVG function displays the maximum, minimum, and average values over any specified time period. ■Features include a REL (deviation measurement) function that uses the measurement value at any moment as a reference, HOLD, and auto power-off functions. ■Protection rating IP66. ▼pH resolution 0.01/0.001 ▼pH, mV, and Pt100 temperature measurement ▼MAX-MIN-AVG, deviation measurement ▼Large-capacity data logger function
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationIt is possible to measure pH and oxidation-reduction potential (ORP) with high precision in mV, as well as to measure temperature using immersion, penetration, or surface probes of Pt100 or Pt1000. The pH electrode can be calibrated at pH values of 4.01, 6.86, or 9.18, with options for 1-point, 2-point, or 3-point calibration. The temperature probe is equipped with an automatic recognition module called "SICRAM," which automatically selects not only the type of connected probe but also the measurement unit. Calibration details from the factory are also stored in memory. The MAX-MIN-AVG function allows for the display of maximum, minimum, and average values over any specified time period. Other features include a REL (deviation measurement) function that displays the deviation (positive or negative value) based on measurements at any moment, a HOLD function, and a user-definable auto power-off function. Additionally, the outer circumference of the main unit and the connector area are equipped with a rubber exterior, and the protection rating is IP67.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration■Using a 4-electrode or 2-electrode conductivity and temperature probe, measurements can be taken for pH, mV, oxidation-reduction potential (ORP), conductivity, liquid resistance, total dissolved solids (TDS), and salinity. ■pH electrode calibration can be performed at one, two, or three points, with the calibration process allowing for the selection of appropriate values from 13 buffer solution values. ■The conductivity probe can be automatically calibrated using one or more conductivity calibration solutions of 147μS, 1413μS, 12880μS, or 111800μS/cm. ■The HD2156.2 features a data logger function, capable of storing up to 20,000 sets of measurement data for three elements out of pH or mV, conductivity, liquid resistance, total dissolved solids (TDS), or salinity, and the saved data can be transmitted to a PC via RS232C and USB2.0. ■The protection rating is IP67 (waterproof specification). ▲Measurement of pH, mV, conductivity, ORP, liquid resistance, total dissolved solids, and salinity ▲Automatic calibration function ▲MAX-MIN-AVG
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration■A conductivity and temperature combined probe with 4 or 2 electrodes that measures conductivity, liquid resistance, total dissolved solids (TDS), and salinity. ■Temperature measurement is also possible with immersion, penetration, or surface probes of Pt100 or Pt1000. ■The conductivity probe can be automatically calibrated with one or more conductivity calibration solutions of 147μS, 1413μS, 12880μS, or 111800μS/cm. ■The temperature probe is equipped with an automatic recognition module "SICRAM" that memorizes the calibration details from the factory. ■The HD2106.2 can function as a data logger, capable of storing up to 36,000 sets of conductivity and temperature measurement data. Stored data can be transmitted to a PC via RS232C and USB2.0. The data storage interval, print content, and baud rate can be set through the menu. ■The HD2106.1 and HD2106.2 are equipped with an RS232C serial port, allowing real-time transmission of measurement data to a PC or printer. ■With the MAX-MIN-AVG function, it displays the maximum, minimum, and average values over any specified time. ■Equipped with a REL (deviation measurement) function that displays the deviation (positive or negative value) based on the measurement value at any moment, a HOLD function, and a cancelable auto power-off function.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration■Using a 4-electrode or 2-electrode conductivity and temperature combined probe to measure conductivity, liquid resistance, and total dissolved solids (TDS) ■Temperature-only measurements are also possible using immersion, penetration, or surface probes of Pt100 or Pt1000 ■The conductivity probe can be automatically calibrated with conductivity calibration solutions of 147μS, 1413μS, 12880μS, or 111800μS/cm ■The MAX-MIN-AVG function displays the maximum, minimum, and average values over any specified time ■Equipped with a REL (deviation measurement) function that uses the measurement value at any moment as a reference, a HOLD function, and a cancelable auto power-off feature ■Protection rating IP67 ▲Conductivity, liquid resistance, total dissolved solids measurement, Pt100 temperature measurement ▲MAX-MIN-AVG, deviation measurement ▲Automatic calibration function
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationeSENSE is a maintenance-free, low-cost CO2 concentration transmitter that employs the latest NDIR (infrared) method, allowing installation in air conditioning and ventilation ducts depending on the choice of living environment or housing. The patented NDIR (non-dispersive infrared absorption) technology provides reliable CO2 measurements through a unique refractive (infrared waveguide) optical sensor treated with gold plating. ■ 2× Analog outputs (excluding -IP50 model): 0-10V (0-2,000ppm CO2) 2-10V (0-2,000ppm CO2) ■ RS485/ModBus network (optional) ■ Three types of housing options: (1) IP30 wall-mounted type (with/without display) (2) IP65 duct type (with/without display) (3) IP50 multi-purpose type (suitable for wall mounting and duct installation)
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration■ High-precision measurement of CO2 using the latest NDIR (non-dispersive infrared absorption) technology ■ Five types of CO2 concentration measurement ranges available ■ Maintenance interval exceeds 5 years ■ Equipped with a serial communication port for connection to a PC or GSM module ■ Standard analog output with 2 channels (mV/mA), optional relay output also available ■ Optional local network communication via RS485 or LonWorksTM ■ 2-channel logger function (optional)
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration■ CO2 gas measurement using the latest infrared (NDIR) technology. ■ CO gas measurement using the latest hybrid thick-film sensor (MMOS) technology. ■ Various outputs allow for connection and control of DDC (Direct Digital Control) devices, dampers, and variable fans. ■ Contributes to reducing energy costs when used in demand control ventilation systems. ■ Equipped with a serial communication port for PC, GSM module, and LAN connection. ■ Maintenance-free for over 5 years.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThis is a temperature and humidity transmitter equipped with a data logger function. In addition to analog output of current or voltage, it also offers RS232C/RS485 serial communication capabilities (available on all models) and a control ON/OFF output (only for models ending in -R). The HD2717T and HD2817T series feature interchangeable probes as a significant characteristic, allowing users to replace the probe with a spare without long interruptions to the process if the need arises. ◎ The HD2717T and HD2817T series temperature and humidity transmitters measure the following elements: Temperature Relative Humidity ◎ Based on the measurements of these elements, the following calculations are performed: Wet Bulb Temperature Dew Point Temperature Absolute Humidity Mixing Ratio ▼ High maintainability with interchangeable, high-precision temperature and humidity probes ▼ Logger function capable of storing 9,000 data points, with variable intervals from 1 second to 4 minutes ▼ Three types of probe shape variations: downward, rear, and separated ▼ RS232C/RS485 serial communication capabilities, analog, and relay output
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration■ All models come with a built-in compass ■ Serial interfaces include RS232C, RS485, RS422, and SDI-12, with communication protocols equipped for ASCII proprietary, NMEA, Modbus-RTU, and SDI-12 ■ All models are equipped with two analog outputs for wind speed and direction ■ Outputs can be factory-set to either DC4–20mA (standard) or DC0–1V, DC0–5V, DC0–10V ■ The optional heater function prevents ice and snow accumulation on the wind direction and speed meter, enabling accurate measurements under all weather conditions ■ An ACCREDIA calibration certificate with traceability can be attached (optional, international mutual certification including Japan under ILAC-MRA) ■ Networking of the wind direction and speed meter is possible via Modbus-RTU output ▼ Measurement range of 0–60m/s, resolution of 0.01m/s, built-in compass ▼ Optional additions for solar radiation, atmospheric pressure, temperature, relative humidity, and rainfall are available ▼ RS232C/RS485/RS422/SDI-12 output + analog output ▼ Use in icy and snowy regions is possible with the heater function option ▼ Low power consumption allows for operation in remote locations using solar panels and batteries
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationA measuring instrument that is installed perpendicular to sunlight using a solar tracking device and measures direct solar radiation (W/m²). The LPPYRHE16 has a field of view of 5° and an inclination angle of 1°, in accordance with ISO 9060:2018 and WMO standards. Its operating principle is based on a passive type thermopile sensor. The sensing surface of the thermopile is coated with matte black paint to ensure that the direct solar radiation sensor is not selective to different wavelengths. The spectral range of the direct solar radiation sensor is determined by a quartz window that protects the sensor from dust and moisture. Thanks to the special quartz, non-selective measurements across a spectral range of 200nm to 4000nm are possible. The sensor used achieves a response time faster than what is required for class B direct solar radiation sensors by ISO 9060:2018. (The required response time is 15 seconds according to ISO 9060:2018, while the LPPYRHE16 is under 9 seconds.) ▼ ISO 9060:2018, WMO compliant class B direct solar radiation sensor ▼ Complete overview of solar radiation elements through combined use with an all-sky solar radiation sensor ▼ Long-term high-precision measurements achieved with automatic temperature compensation feature ▼ Calibration certificate included as standard
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationMeasurement of illuminance (lux) in the near ultraviolet spectrum region VIS-NIR and the photon flux in the UVA, UVB, and PAR regions (400–700nm). ■LPPHOT03 Measurement of illuminance (lux), defined as the ratio of luminous flux (lumens) to unit area (m²). The spectral response curve of the photometric measurement probe approximates the response curve of the human eye known as the photopic standard sensitivity. ■LPPAR03 Measurement of the ratio of the number of photons incident on a surface per second to unit area (m²) in the spectral range of 400–700nm. This quantity is defined as PAR: Photosynthetically Active Radiation. ■LPUVA03 Measurement of radiative illuminance (W/m²), defined as the ratio of the radiative flux (W) incident on a surface to unit area (m²) in the UVA spectral range (315–400nm). With the adoption of a new photodiode, LPUVA03 is insensitive to visible and infrared light. ■LPUVB03BLAV Measurement of radiative illuminance (W/m²), defined as the ratio of the radiative flux (W) incident on a surface to unit area (m²) in the UVB spectral range (280–315nm). The spectral sensitivity is centered at 304nm with a bandwidth (FWHM) of 5nm.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationMainly used in the field of meteorological measurements for measuring longwave radiation (far infrared region). The measurements target wavelengths exceeding 4.5 μm. Longwave radiation can be obtained from the output signal of the thermopile and the temperature of the longwave radiometer, with the temperature measured by a built-in 10kΩ NTC in the longwave radiometer. By adding another longwave radiometer to measure upward infrared radiation and an albedometer to measure shortwave radiation (<3 μm), it can also be used for energy balance investigations. Two versions of the longwave radiometer are available: ● LPPIRG01: μV/(W/m²) output ● LPPIRG01S: RS485 Modbus-RTU output *Provided with a calibration report obtained from outdoor comparative measurements (for at least one clear night) with a reference instrument calibrated at WRC (World Radiation Center). ▼ ISO9060:2018 compliant longwave (infrared) meter ▼ Measurement range -300 to +300 W/m² ▼ Built-in silica gel cartridge for condensation prevention (replaceable) ▼ Robust construction designed for long-term use, M12 connector connection
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration