Measured the thickness variation of non-electrolytic nickel plating: measured 72 points with 6 outer and inner diameters of pipes, 12 pieces each.
Electroless nickel plating is characterized by its ability to form a relatively uniform coating on products with complex shapes. In this instance, we conducted electroless nickel plating on 12 pipe products aiming for a film thickness of 12μm, measuring the thickness at three points on the outer diameter and three points on the inner diameter. We not only measured the outer diameter but also split the pipes to measure the thickness in the inner diameter section, confirming the degree of thickness variation and uniformity between the outer and inner diameters.
[We measured the thickness at a total of 72 points: 12 products × 6 points]
Outer diameter: Average of 36 points: 12.71μm
Inner diameter: Average of 36 points: 11.80μm

Inquiry about this news
Contact Us OnlineMore Details & Registration
Details & Registration