Medical institutions should ensure that unnecessary communications are blocked to protect the core from ransomware attacks.
One-way communication restriction device data diode OWCD series
Damage from ransomware infections is further increasing. A slight improvement in convenience can lead to unexpected risks. Let's be mindful of implementing multi-layered intrusion and information leakage countermeasures.
It is said that "with zero trust in security measures, boundary control for intrusion prevention is outdated..." However, there are still vulnerabilities lurking somewhere in security, and intrusions occur from there. Zero trust is meant to prevent "lateral movement" and "authentication acquisition," and the protection of critical devices requires the premise of "not being connected." The physical data diode OWCD provides hassle-free "disconnected" boundary control. Did you know there are actually two ways to use it? One is to protect the core by "not allowing anything to intrude." The other is to prevent takeover damage by "not allowing anything to exit." Ransomware relies on remote communication with the outside. By shutting that down, it prevents leakage and encryption. By combining it with access authentication and virus detection mechanisms, we enhance the overall availability of your medical system and protect medical services. Not only in medical institutions, but government agencies and companies that skillfully combine OWCD to strengthen security while improving convenience are rapidly increasing. We encourage your company to utilize the physical data diode OWCD. Please refer to our website for more information. There are also video explanations! Check out the related links below, including contact information.
Inquire About This Product
basic information
The overall system of a hospital is composed of various systems such as diagnostic medical devices, medical records, and medical administration. Access authentication for convenient use, detection of viruses brought in by someone, as well as boundary control to prevent hijacking of medical record systems and diagnostic medical devices and to protect backup data are also very important. Intruders aim to take something valuable (manipulate) back with them. If there is no route, the targeted damage does not occur. However, even with the same boundary control, things like firewalls that require authentication settings can lead to mistakes or forgetfulness. Each time personnel or systems change, and each time a virus protection patch is released, settings need to be adjusted, so it is uncertain when mistakes may occur... management and costs are significant. A physical data diode restricts communication to one direction on an electronic circuit, preventing any backflow. Since user settings and security patches are irrelevant, it actually pairs perfectly with "zero trust" and multi-layered defense! For those in critical infrastructure such as government agencies, power plants, and transportation systems where even the slightest mistake is unacceptable, as well as various research institutions, adoption is being decided one after another. The medical system is also critical infrastructure, so please consider incorporating it.
Price information
We also accept implementation system engineering (scope, cost, and delivery time are negotiable). It can be said that we are in an era where breaches are almost guaranteed. It is best for medical devices and medical record systems to have no unintentional connections to external routes. Intrusion pathways can be found even in the smallest gaps. Let’s be cautious to prevent business collapse. We can also propose methods to maintain routes for remote maintenance by manufacturers for inspection equipment and the like. This is even more robust than ZTNA (Zero Trust Network Access). Please feel free to consult with us. For inquiries, please contact us through our company website.
Price range
P5
Delivery Time
※Standard products will take 7 weeks from the order. For more details, please contact us through our website above.
Applications/Examples of results
Medical management system (one-way communication control from medical record system to medical office system) Traffic information system (one-way communication control from control system to public web server) Remote monitoring system for industrial equipment (intrusion prevention at data transmission unit) Countermeasures against backflow from external data file acquisition lines in government agencies (no communication signals emitted at all) Additionally, it is used in government agencies, power plants, defense systems, manufacturers' research laboratories, and production information transmission points. There is also an increasing demand for solutions such as usage in supply chains between companies, remote maintenance, and enhanced file management. Data diodes are typically placed quietly and without hassle. They often do not even appear in diagrams explaining examples of ransomware countermeasures. They are subtly hidden. Try asking SIers, "Aren't you using data diodes?" Among them, the physical data diode OWC-D, which restricts the circuit to one-way communication at the electrical circuit level, will further enhance the safety and security of our customers. For inquiries, please visit our company website above.
catalog(24)
Download All Catalogs
Company information
Our company is a member of the Mitsubishi Heavy Industries Group, serving as a design technology partner for Mitsubishi Heavy Industries, where we engage in planning and mechanical design for prime movers (steam turbines/boilers, gas turbines, water turbines), pumps, and various plants, as well as instrumentation control system planning and electrical design. In order to meet the increasingly diverse and sophisticated needs of our customers, we will continue to challenge ourselves to improve our technological capabilities, streamline operations, and reduce costs based on the trust we have built with users. Through this, we are developing activities that contribute to society by providing the products and engineering capabilities we have cultivated so far to everyone. Alongside the sale of products related to IoT, manufacturing DX, and on-site monitoring/condition monitoring, we will focus on custom orders, customization, and system construction to realize your ideas. We encourage you to consider utilizing our services. https://eng.power.mhi.com