●Compact and lightweight ●Constant digital display of two components
● Two-stage alarm with lamp, buzzer, and vibration ● Oxygen 21% and zero toxic gas adjustment, automatic calibration for toxic gases ● Intrinsically safe explosion-proof structure (i2G3 certification number T62160) ● Using the optional "M176T-1102G-KT10," both remote measurement and body-worn measurement are possible.
Inquire About This Product
basic information
■Common Specifications ItemOxygenCarbon MonoxideHydrogen Sulfide Measurement PrincipleGalvanic Cell TypeConstant Potential Electrolytic Type SensorM176T-1102G-206GM176T-1102G-607EM176T-1102G-605E Measurement Range0.0 to 25.0%0 to 300ppm0.0 to 30.0ppm Minimum Scale0.10%1ppm0.1ppm Service Range25.1 to 42.0% (Above 42.0% HI Display)301 to 999ppm (Above 1000ppm HI Display)30.1 to 50.0ppm (Above 50.1ppm HI Display) Sampling MethodDiffusion Type Indication Accuracy±0.7% O2Within ±5% of Full Scale 90% Response TimeWithin 20 secondsWithin 30 seconds First AlarmBelow 18%Above 50ppmAbove 10.0ppm Second Alarm-Above 150ppmAbove 30.0ppm Alarm MethodLightFirst FlashingFirst Alarm: Slow Flashing Second Alarm: First FlashingFirst Alarm: Slow Flashing Second Alarm: First Flashing BuzzerFirst IntermittentFirst Alarm: Slow Intermittent Second Alarm: First IntermittentFirst Alarm: Slow Intermittent Second Alarm: First Intermittent
Price range
Delivery Time
Applications/Examples of results
●User-replaceable sensor and battery.
Company information