The ACC performs stable cooling control using feedback control with thermocouples.
Standard Type ACC - Stable cooling control is achieved using feedback control with a thermocouple. - The main power switch and cooler start switch are separated, allowing cooling to begin after setting the temperature. An option is available to issue an alarm for unmet cooling temperature and output the discharge temperature as 4-20mA. Pressure Gauge Equipped Type ACCP - The main power switch and cooler start switch are separated, allowing cooling to begin after setting the temperature. An option is available to issue an alarm for unmet cooling temperature and output the discharge temperature as 4-20mA. - Equipped with a pressure gauge for visual confirmation of pressure. An option is available to issue an alarm for insufficient pressure and output the pressure as 4-20mA. Pressure Gauge and Flow Meter Equipped Type ACCPFM - The main power switch and cooler start switch are separated, allowing cooling to begin after setting the temperature. An option is available to issue an alarm for unmet cooling temperature and output the discharge temperature as 4-20mA. - Equipped with a pressure gauge for visual confirmation of pressure. An option is available to issue an alarm for insufficient pressure and output the pressure as 4-20mA. - Equipped with a flow meter for visual confirmation of flow rate. An alarm for insufficient flow can be issued, and the flow rate can be output as 4-20mA.
Inquire About This Product
basic information
ModelFeatures ACC-0.7MPa-300LTemperature controller mounted on the surface ACCP-0.7MPa-300LTemperature controller and pressure gauge mounted on the surface ACCPFM-0.7MPa-200LTemperature controller, pressure gauge, and flow meter mounted on the surface ACCPFM-0.7MPa-300LTemperature controller, pressure gauge, and flow meter mounted on the surface [Options] TypeFunction TPTemperature controller with radiation thermometer input specification TMR1Timer mounted on the surface - One-shot cooling setting TMR2Timer mounted on the surface - Cool preservation time setting TMR3Timer mounted on the surface - Display of cumulative cooling time for predictive maintenance BUZBuzzer sounds for 10 seconds when time is up RC1Remote control: Start/stop cooling with external signal RC2Remote control: Control output voltage with external 4-20mA signal RSPRemote control: Set target value with external 4-20mA signal MONMonitor output: Output injection temperature as 4-20mA signal externally RS485RS-485 communication TCBThermocouple disconnection alarm APAir pressure shortage alarm
Price range
Delivery Time
Applications/Examples of results
Feedback Control of Cold Air Coolers 1. Cooling of vials 2. Low-temperature drying of vial bottles 3. Partial cooling of culture media 4. Cooling of test tubes 5. Refrigerant for Graham coolers 6. Refrigerant for Aleen coolers 7. Refrigerant for Jim Roth coolers 8. Refrigerant for Dewar coolers 9. Refrigerant for Liebig coolers 10. Cooling of samples for electron microscopes 11. Cooling and solidification of 3D printers 12. Reproduction of thermal distortion 13. Low-temperature setting for tensile testing machines 14. Rapid cooling for soldering 15. Cooling of printed circuit boards 16. Cooling tests for electronic components 17. Cooling and solidification of resin solvents 18. Cooling during film fusing sealing 19. Cooling of film cutting blades 20. Cooling of hot melt in brick packs 21. Rapid cooling of hot melt 22. Quality improvement during resin hole cutting 23. Prevention of thread breakage through needle cooling 24. Cooling of sensors in high-temperature environments 25. Low-temperature degradation testing of springs 26. Cold resistance testing of color filters 27. Development of crystal structures in magnetic materials 28. Evaluation of low-temperature operation of semiconductors 29. Low-temperature aging of electronic components 30. Temperature drift testing of electronic devices 31. Cooling of rubber sheets
Line up(3)
| Model number | overview |
|---|---|
| Standard type ACC | https://www.heat-tech.biz/abcooler/abc-ss/18718.html#ACC |
| Pressure gauge equipped type ACCP | https://www.heat-tech.biz/abcooler/abc-ss/18718.html#ACCP |
| Pressure gauge and flow meter equipped type ACCPFM | https://www.heat-tech.biz/abcooler/abc-ss/18718.html#ACCPFM |
catalog(1)
Download All CatalogsCompany information
5 reasons that HEATTECH is selected 1. The rich selection of 5 principles and 71 types. Air Blow heater , Near-infrared, Middle-infrared, Far-infrared, and UV heater From the 71 types of products based on the 5 principles of heating system, we will propose the best heater. 2. 9 series 88 types of heater controllers. Manual, Automatic, Speed proportional, Remote control, IOT compliant, Noncontact heating control, One-shot heating, Multistage heating, etc. We propose the optimal heater controller from the multifunctional products. 3. Construction method study materials We have published a number of technical documentation online seminars. 4. Sense of security of verification before introduction. Test piece, test laboratory, in user can verify before introduction. 5. Low-budget one-stop introduction To introduce in testing way, the laboratory kit which gathered something necessary was prepared. : Member of the Kobe Chamber of Commerce and Industry : Member of the Society of Material Science Japan : Member of the Society of Thermophysical Properties Japan : Member of the Japan External Trade Organization Trade Tie-up Promotion Program









![[FA Site Improvement Case] Mirroring Notification of Equipment Status via "Wireless"](https://image.mono.ipros.com/public/product/image/3e8/2000332370/IPROS52709412210469612823.jpeg?w=280&h=280)