Support operational improvements by comparing the simplified electric power consumption of large-capacity circuits over a period.
PAL-Plus type E2 | Hexacore Corporation
Simple measurements of target circuits from 125A to 630A. We will accumulate reference data to compare usage trends before and after operational changes and operating days, in order to consider energy-saving measures.
The large-capacity circuits within the factory may make it difficult to grasp usage trends based solely on monthly electricity consumption, as these trends can vary depending on operational days and periods. The "PAL-Plus type E2" uses a pair of current detection units to measure the alternating current of single-phase three-wire and three-phase three-wire circuits. The simple power sensor "PAL-Plus type E2" also uses a pair of current detection units to calculate simple power and simple cumulative electricity consumption for three-phase circuits and others. 【Challenges】 - I want to compare usage trends of large-capacity circuits by period. - I want to confirm differences due to operational days and changes in operations. - I need continuous data for improvement considerations. 【Benefits of Implementation】 - Continuous recording of simple electricity consumption for large-capacity circuits. - Comparison before and after changes across operational days and periods. - Accumulation of materials for considering the next operational improvements. You can check the detailed specifications and compatible circuits in the downloadable materials. For more details, please download the materials or feel free to contact us.
Inquire About This Product
basic information
**Main Specifications** - Supported Circuits: Single-phase 3-wire, Three-phase 3-wire - Sensor Configuration: Two current detection units used as a pair - Measurement Items: AC current, simple power, simple accumulated energy, etc. - Rated Current: 125A, 250A, 400A, 630A - Communication Method: Modbus RTU (RS-485) - Installation Method: Split clamp type - Upper Connection Examples: PLC, Gateway BOX, Monitoring Software CEW-M4 Simple power and simple accumulated energy are reference values calculated from pre-set voltage and power factor values along with measured current. Please check the documentation for measurement accuracy, applicable cable diameter, wiring methods, and conditions for application to the target circuit.
Price information
Please feel free to contact us.
Delivery Time
Applications/Examples of results
【Examples of Use】 - Simple measurement of large capacity circuits in single-phase three-wire and three-phase three-wire systems - Comparison of usage trends before and after operational changes on operational days and periods - Verification against production schedules, operational records, and inspection records - Accumulation of reference data for considering energy-saving measures The simple values are reference values calculated from the set voltage and power factor values and the measured current. They are not suitable for determining the condition of equipment during short-term operation or for individual devices.
catalog(1)
Download All CatalogsCompany information
HexaCORE Co., Ltd. (formerly Chuo Seisakusho Co., Ltd.) Head Office and Factory
Company profile: Hexacore Inc. designs, manufactures and sells telecommunications and data centre equipment, as well as measurement and monitoring systems. In a world moving towards sustainability, telecommunications and energy infrastructure remain essential to our daily lives. Hexacore offers solutions that support the construction of safe and efficient communication facilities, promoting energy efficiency and backed by technical expertise and a customer-oriented support system. Notice: Please note that, effective 1 April 2023, our company name was changed from Chuo Seisakusho Co., Ltd. to Hexacore Inc.


![Deburring Machine "Twin Baritor" [Eligible for Small and Medium Enterprise Productivity Investment Subsidy]](https://image.mono.ipros.com/public/product/image/6d3/2000308654/IPROS16685940644635288329.png?w=280&h=280)

![The first step in automating factories and warehouses starts with floor leveling [with case studies included].](https://image.mono.ipros.com/public/product/image/8e6/2001522448/IPROS11175175298099575604.png?w=280&h=280)