Support for phased implementation by checking 2CT measurements in the cloud.
PAL-Plus type E2× Gateway BOX | Hexacore Inc.
Introducing a 2CT configuration into single-phase 3-wire and three-phase 3-wire circuits. Verify the installation, wiring, and collection conditions in a limited circuit, and it can be gradually expanded to similar circuits.
When introducing type E2 into single-phase three-wire and three-phase three-wire circuits, it is necessary to check in advance the installation positions of the two current detection units, the diameter of the target cables, the space within the panel, and the wiring routes of the bus cables. By combining the PAL-Plus type E2 with the gateway BOX and initially limiting the target circuit, the installation conditions for the 2CT configuration and the method for confirming data on the cloud can be verified on a small scale. By combining the PAL series with the gateway BOX, measurement data from the target circuit can be sent to the cloud via mobile lines, allowing for confirmation through graphs or CSV files. [Challenges] - I want to confirm the installation conditions for the 2CT configuration in advance. - I want to check the wiring and viewing methods for the limited circuit. - I want to expand to three-phase circuits with the same conditions. [Effects of Implementation] - Confirm the 2CT configuration in the limited circuit. - Organize installation, wiring, and viewing conditions in advance. - Facilitate expansion to similar three-phase circuits. Detailed specifications and connection configurations can be confirmed in the downloadable materials. For more information, please download the materials or feel free to contact us.
Inquire About This Product
basic information
【PAL-Plus typeE2】 - Supported circuits: Single-phase 3-wire, Three-phase 3-wire - Current detection unit: Used in pairs - Rated current: 125A, 250A, 400A, 630A - Measurement items: AC current, simple power, simple cumulative energy, etc. - Communication method: Modbus RTU (RS-485) 【Gateway BOX】 - Connects the PAL series to the bus cable via a connector - Power supply: AC100V - Mobile network, cloud monitoring, CSV output, notifications based on set conditions The simple values are reference values based on the set voltage, set power factor, and measured current.
Price information
Please feel free to contact us.
Delivery Time
Applications/Examples of results
【Examples of Use】 - Pre-check before introducing type E2 into single-phase three-wire and three-phase three-wire circuits - Preliminary consideration of the installation position of 2CT, cable diameter, and space within the panel - Confirmation of bus cable wiring, AC 100V power supply, and cloud viewing methods - After testing in a limited circuit, phased deployment to similar circuits The simplified values are reference values based on the set voltage, set power factor, and measured current. Actual power factor variations may introduce error factors.
catalog(3)
Download All CatalogsCompany information
HexaCORE Co., Ltd. (formerly Chuo Seisakusho Co., Ltd.) Head Office and Factory
Company profile: Hexacore Inc. designs, manufactures and sells telecommunications and data centre equipment, as well as measurement and monitoring systems. In a world moving towards sustainability, telecommunications and energy infrastructure remain essential to our daily lives. Hexacore offers solutions that support the construction of safe and efficient communication facilities, promoting energy efficiency and backed by technical expertise and a customer-oriented support system. Notice: Please note that, effective 1 April 2023, our company name was changed from Chuo Seisakusho Co., Ltd. to Hexacore Inc.