Continuous measurement of direct current | Remote monitoring of current values and load fluctuations in railway equipment.
DC Current Measurement and Remote Monitoring System "iDC-SVS4" | Hexacore Corporation
Remote monitoring of current values and load fluctuations in railway equipment. Continuous monitoring of equipment circuits with a DC current sensor that supports 30A to 500A.
Are you able to continuously monitor the direct current in railway substations, signal equipment rooms, and along the line facilities, not just during inspections? Relying solely on instantaneous measurements may overlook changes due to time of day or load conditions. The "iDC-SVS4" is a sensor that supports 30A, 50A, 100A, 250A, and 500A, allowing for continuous measurement of direct current and transmission of measurement data to a monitoring server. You can remotely check the current value, load fluctuations, and past history, and in combination with monitoring software, it can also respond to notifications based on set thresholds. A single relay device can accommodate up to 1,024 points, allowing you to expand the monitoring range from important circuits to multiple circuits. Usage scenarios: - Monitoring direct current in railway substations, signal equipment rooms, and along the line facilities - Checking current values and history of direct current power supply circuits in railway facilities - Confirming inspection targets and notification status before on-site visits Expected benefits from implementation: - Understanding current changes over time outside of patrols - Consolidating measurement information from multiple circuits for review - Organizing inspection targets and confirmation details in advance to streamline equipment management We will propose configurations based on monitoring targets, number of circuits, cable diameter, and installation environment.
Inquire About This Product
basic information
Specification Overview: The "iDC-SVS4" is a monitoring system that continuously measures the current value of a direct current circuit, allowing remote verification of current values, load fluctuations, and history. Direct current sensors can be selected from 30A, 50A, 100A, 250A, and 500A, enabling consideration of monitoring configurations that suit the scale of the equipment, from critical circuits to numerous circuits. It supports notifications based on thresholds, temporary data storage during communication interruptions, and initial installation in our distribution boards. Detailed equipment configurations, specifications for each sensor, measurement accuracy, applicable conditions, number of connectable units, monitoring items, screen examples, and data storage methods are available in the SVS catalog. Those considering implementation in direct current distribution boards, unmanned stations, substations, power plants, and traffic/disaster prevention facilities are encouraged to first download and review the related materials. For configurations and selections tailored to equipment conditions, please feel free to contact us.
Price information
Please feel free to contact us.
Delivery Time
Applications/Examples of results
Main intended use: It is assumed to be used for continuously measuring the DC power supply circuits for control and communication of railway equipment used in railway substations, signal equipment rooms, and along the line communication facilities, allowing for the monitoring of current value trends, including during intervals of routine inspections. By accumulating the load trends during normal conditions, differences before and after changes in time periods or equipment operations can be compared. For such operations: - Time-series verification of load fluctuations and inspection support - Confirmation of current values and histories of multiple circuits in the same monitoring environment - After threshold notifications occur, verification of changes in the target circuit and surrounding conditions - Common measurement data can be referenced among responsible personnel to assist in inspection preparation and record-keeping tasks This product does not directly diagnose faults or deterioration from current data. By confirming measurement results alongside inspection records and equipment information, it can be utilized as foundational data to aid in maintenance decisions.
catalog(1)
Download All CatalogsCompany information
HexaCORE Co., Ltd. (formerly Chuo Seisakusho Co., Ltd.) Head Office and Factory
Company profile: Hexacore Inc. designs, manufactures and sells telecommunications and data centre equipment, as well as measurement and monitoring systems. In a world moving towards sustainability, telecommunications and energy infrastructure remain essential to our daily lives. Hexacore offers solutions that support the construction of safe and efficient communication facilities, promoting energy efficiency and backed by technical expertise and a customer-oriented support system. Notice: Please note that, effective 1 April 2023, our company name was changed from Chuo Seisakusho Co., Ltd. to Hexacore Inc.