Nichiyu Electric Manufacturing Co., Ltd. New-FM Leakage Circuit Breaker ES100AH (ES103AH) MES100AH (MES103AH)
No characteristic variation due to ambient temperature changes! 100AF high cutoff capacity, fully electromagnetic leakage circuit breaker that allows immediate re-insertion after tripping.
The "New-FM Series (ES100AH / MES100AH)" from Nichiko Electric Manufacturing Co., Ltd. is a 100AF high breaking capacity leakage circuit breaker that employs a "fully electromagnetic (hydraulic-magnetic type)" design without thermal operating elements such as bimetals in its overcurrent tripping device. It is unaffected by ambient temperature and allows for 100% rated current flow. Additionally, there is no need to wait for a reset after a trip (tripping operation), enabling immediate re-engagement and thus reducing equipment downtime. In addition to the standard wiring protection model (ES100AH), a motor protection compatible model (MES100AH) is also available in the lineup.
Inquire About This Product
basic information
【Target Models】 - General Wiring: ES100AH (3-pole: ES103AH) - Motor Protection Combined: MES100AH (3-pole: MES103AH) 【Common and Main Specifications】 - Frame: 100AF (High Breaking Capacity Type) - Number of Poles: 3-pole (ES103AH / MES103AH) - Phase Wire Type: 1φ2W, 1φ3W, 3φ3W - Rated Voltage: AC100-200-415V Common (Usable Voltage Range: 80-506V) - Standard Rated Current: 50A, 60A, 75A, 100A (For other ratings, please refer to the catalog) - Rated Sensitivity Current: 30mA / 100・200・500mA Switchable - Operating Time: High Speed Type (within 0.1 seconds) / Time Delay Type (0.3・0.8・1.2・1.6 seconds, 4-step switchable) - Overcurrent Tripping Method: Complete Electromagnetic Type - Applicable Standards: JIS C 8201-2-2 Ann2 - Standard Accessories for Surface Type: Phase Separator *For details on rated breaking capacity (kA), external dimensions, and accessories, please check the catalog.
Price range
Delivery Time
Applications/Examples of results
- Power control panels and main circuit breakers for factories, as well as branch protection requiring high interrupting capacity - Motor circuit protection for various industrial machines such as pumps, fans, and conveyors (MES100AH) - Control panels in environments with significant temperature fluctuations or where internal temperatures tend to be high - Production lines requiring rapid recovery and re-engagement during instantaneous power outages or trip occurrences - Leakage protection for inverter-driven equipment 【Main Features】 ■ High-precision protection characteristics unaffected by ambient temperature (no temperature correction needed) ■ Immediate re-engagement possible without waiting for cooling time after interruption ■ High interrupting capacity specifications accommodate large short-circuit currents in main lines and equipment ■ Compatible with a wide rated voltage range of AC100-200-415V ■ Easy ground fault selective interruption coordination with rated sensitivity current (30mA, or switchable 100/200/500mA) and operation time switching ■ Suppresses unwanted operation due to high-frequency components from inverter circuits and lightning impulses ■ Standardized dimensions, panel cutouts, and depth dimensions with circuit breakers from the same series streamline panel design *For more details, please download the PDF catalog or feel free to contact us.
Detailed information
-

Nihon Kiko Manufacturing's fully electromagnetic circuit breaker New-FM leakage circuit breaker ES100AH (ES103AH) MES100AH (MES103AH)
-

Nihon Kōsokudō's complete electromagnetic circuit breaker New-FM leakage circuit breaker ES100AH (ES103AH) MES100AH (MES103AH)
-

Nihon Kōsokudō's complete electromagnetic circuit breaker New-FM leakage circuit breaker ES100AH (ES103AH) MES100AH (MES103AH)
-

Nihon Kōsokudō's complete electromagnetic circuit breaker New-FM leakage circuit breaker ES100AH (ES103AH) MES100AH (MES103AH)
-

Nihon Kiko Manufacturing's complete electromagnetic circuit breaker New-FM leakage circuit breaker ES100AH (ES103AH) MES100AH (MES103AH)
-

Nihon Kiko Manufacturing's fully electromagnetic circuit breaker New-FM leakage circuit breaker ES100AH (ES103AH) MES100AH (MES103AH)
-

Nihon Kiko's complete electromagnetic circuit breaker New-FM leakage circuit breaker ES100AH (ES103AH) MES100AH (MES103AH)
-

Nihon Kōsokudō's complete electromagnetic circuit breaker New-FM leakage circuit breaker ES100AH (ES103AH) MES100AH (MES103AH)
-

Nihon Kou Denki Seisakusho's complete electromagnetic circuit breaker New-FM leakage circuit breaker ES100AH (ES103AH) MES100AH (MES103AH)
catalog(5)
Download All Catalogs
Company information
Nikko Electric's new base, Satellite Akiba (Tokyo, Akihabara), opened in February 2024. We aim to create a facility that connects not only sales but also factory technology and the web, allowing us to propose the most optimal transformers in real-time! If you have any issues regarding transformers, coils, or reactors, please feel free to consult with Nikko Electric. We will propose the best transformers through discussions with our customers.