List of CAE products

  • classification:CAE

766~780 item / All 3885 items

Displayed results

Achieves high collection efficiency through electrostatic methods. Offers a wide range of products from large to small sizes. Also compatible with water-soluble oil mist.

  • small-mistcollector.png
  • air conditioning

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Rich equipment and expertise! We will elucidate the molecular structures of materials in general through chemical instrument analysis!

  • Analytical Equipment and Devices
  • Contract Analysis
  • Contract Analysis

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration
NMR spectrum.png

NMR analysis of liquid crystal compounds

At Aites Co., Ltd., we conduct "NMR analysis of liquid crystal compounds." NMR is an analytical method that reveals the connections between atoms that make up a molecule, and it is used alongside mass spectrometry and infrared spectroscopy for determining the structure of compounds. In the downloadable materials, we highlight the 1H NMR, 13C NMR, and DEPT measurements of 4-butoxy-4'-cyanobiphenyl (CAS number 52709-87-2), which is used as a liquid crystal component, and introduce the information obtained from NMR. Please feel free to download and take a look.

The analysis device also supports the analysis and evaluation of polymers! Information on the configuration and principles of high-temperature SEC equipment is provided!

  • Contract measurement
  • Contract Analysis
  • Other analyses

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration
strain gauges.png

Poisson's ratio measurement

At Aites Co., Ltd., we conduct "Poisson's ratio measurement." Poisson's ratio is the ratio of longitudinal to lateral strain that occurs when a load is applied to an object, and it is necessary for strength calculations of materials. In the downloadable materials, we introduce the results of attaching strain gauges to test specimens, applying tensile loads using a universal testing machine, and examining the longitudinal and lateral strains obtained from the strain gauges. Please feel free to download and take a look.

GC-MS is used for qualitative and quantitative analysis of low molecular organic substances! Data was obtained and compared using incense and sandalwood!

  • Analytical Equipment and Devices
  • Contract Analysis
  • Other contract services

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration
?chemical analysis.png

Chemical Analysis Concierge Service

We would like to introduce our "Chemical Analysis - Trust Us Service." When conducting component analysis of foreign substances or stains on products, it can be challenging to determine whether organic analysis or inorganic analysis is more suitable, and which specific analysis within organic or inorganic is the most appropriate. We provide a comprehensive service for customers who are struggling with the selection of analysis methods. Since each analysis device can measure different targets, it is necessary to choose a method that fits the purpose based on the information available.

Depending on the panel size, it is possible to analyze using different ICP-AES/MS devices!

  • panel_ICP_2.png
  • Analysis Services

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration
?chemical analysis.png

Chemical Analysis Concierge Service

We would like to introduce our "Chemical Analysis - Trust Us Service." When conducting component analysis of foreign substances or stains on products, it can be challenging to determine whether organic analysis or inorganic analysis is more suitable, and which specific analysis within organic or inorganic is the most appropriate. We provide a comprehensive service for customers who are struggling with the selection of analysis methods. Since each analysis device can measure different targets, it is necessary to choose a method that fits the purpose based on the information available.

We have published cross-sectional observations of the fracture surface and elemental maps of the fracture area!

  • Contract Analysis
  • Contract Inspection
  • Contract Analysis

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Distinguish compounds with similar molecular structures through NMR analysis, elucidating the binding positions of side chains and substituents, as well as branching structures!

  • Contract Analysis
  • Analysis Services
  • Contract Analysis

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration
?chemical analysis.png

Chemical Analysis Concierge Service

We would like to introduce our "Chemical Analysis - Trust Us Service." When conducting component analysis of foreign substances or stains on products, it can be challenging to determine whether organic analysis or inorganic analysis is more suitable, and which specific analysis within organic or inorganic is the most appropriate. We provide a comprehensive service for customers who are struggling with the selection of analysis methods. Since each analysis device can measure different targets, it is necessary to choose a method that fits the purpose based on the information available.

We will introduce an analysis example confirming that the welded area has a large distribution of grain crystals.

  • image_02.png
  • image_03.png
  • image_05.png
  • image_06.png
  • image_07.png
  • Analysis Services
  • Contract Analysis

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration
Phasemap.png

Example of analysis of compounds at the SAC solder and Ni pad interface.

We will introduce an example of the analysis of compounds formed at the interface between Sn-Ag-Cu solder and NiP pads. At the interface of NiP pads and Sn-Ag-Cu solder, compounds such as (Ni,Cu)3Sn4 and (Cu,Ni)6Sn5 grow, and surface analysis using EDX shows the distribution of Ni, Cu, and Sn within these compounds. The EBSD method is a technique that analyzes based on the crystallographic information of the sample. By combining it with elemental analysis using EDX, it is possible to estimate the composition, and in some cases, it may be possible to analyze using crystallographic data for Ni3Sn4 and Cu6Sn5 as substitutes.

It will lead to the determination of development direction and acceleration! We will respond with abundant technology, knowledge, and equipment.

  • 2021-03-12_14h26_36.png
  • 2021-03-12_14h26_46.png
  • 2021-03-12_14h26_56.png
  • 2021-03-12_14h27_08.png
  • 2021-03-12_14h27_21.png
  • 2021-03-12_14h27_33.png
  • 2021-03-12_14h27_46.png
  • 2021-03-12_14h27_57.png
  • 2021-03-12_14h28_07.png
  • Analysis Services
  • Other contract services

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration
?chemical analysis.png

Chemical Analysis Concierge Service

We would like to introduce our "Chemical Analysis - Trust Us Service." When conducting component analysis of foreign substances or stains on products, it can be challenging to determine whether organic analysis or inorganic analysis is more suitable, and which specific analysis within organic or inorganic is the most appropriate. We provide a comprehensive service for customers who are struggling with the selection of analysis methods. Since each analysis device can measure different targets, it is necessary to choose a method that fits the purpose based on the information available.

Even with larger-sized implementation boards, resin embedding is possible without cutting before embedding! We will introduce cases with and without heat generation prevention treatment.

  • image_04.png
  • image_05.png
  • image_06.png
  • image_07.png
  • Analysis Services
  • Other contract services

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration
temperature profile.png

About the curing temperature of epoxy resin free from hazardous substances.

We conducted measurements to reconfirm the temperature of heat generation during curing, following the change to a non-toxic epoxy resin. When using a large amount of resin, we apply heat generation prevention treatment for resin embedding. Without this treatment, the temperature can rise up to 138°C during curing. However, by applying the heat generation prevention treatment even with a large amount of resin, we were able to keep the heat generation during curing within 30°C.

The measured silicon wafer is single crystal! The IPF map, pole figure, and inverse pole figure resulted in relatively simple outcomes.

  • 2021-07-02_17h05_12.png
  • 2021-07-02_17h05_23.png
  • 2021-07-02_17h05_26.png
  • 2021-07-02_17h05_40.png
  • Analytical Equipment and Devices
  • Analysis Services

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration
Phasemap.png

Example of analysis of compounds at the SAC solder and Ni pad interface.

We will introduce an example of the analysis of compounds formed at the interface between Sn-Ag-Cu solder and NiP pads. At the interface of NiP pads and Sn-Ag-Cu solder, compounds such as (Ni,Cu)3Sn4 and (Cu,Ni)6Sn5 grow, and surface analysis using EDX shows the distribution of Ni, Cu, and Sn within these compounds. The EBSD method is a technique that analyzes based on the crystallographic information of the sample. By combining it with elemental analysis using EDX, it is possible to estimate the composition, and in some cases, it may be possible to analyze using crystallographic data for Ni3Sn4 and Cu6Sn5 as substitutes.

It is possible to analyze with good sensitivity using thermal desorption GC-MS analysis! We propose methods tailored to the symptoms of issues and objectives.

  • GCMS_bleed out.png
  • GCMS_cable ties.png
  • GCMS_nylon 66.png
  • Other analyses
  • Contract Analysis
  • Analysis Services

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration
?chemical analysis.png

Chemical Analysis Concierge Service

We would like to introduce our "Chemical Analysis - Trust Us Service." When conducting component analysis of foreign substances or stains on products, it can be challenging to determine whether organic analysis or inorganic analysis is more suitable, and which specific analysis within organic or inorganic is the most appropriate. We provide a comprehensive service for customers who are struggling with the selection of analysis methods. Since each analysis device can measure different targets, it is necessary to choose a method that fits the purpose based on the information available.

Introducing the advantages and disadvantages of 3D construction using X-ray CT and FIB slice cross-sections, as well as the 3D construction method using mechanical polishing!

  • Structural Analysis

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Mechanical grinding allows for a wide range of processing and observation! We will propose appropriate processing and observation methods or combinations.

  • Analysis Services
  • Other contract services

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration
temperature profile.png

About the curing temperature of epoxy resin free from hazardous substances.

We conducted measurements to reconfirm the temperature of heat generation during curing, following the change to a non-toxic epoxy resin. When using a large amount of resin, we apply heat generation prevention treatment for resin embedding. Without this treatment, the temperature can rise up to 138°C during curing. However, by applying the heat generation prevention treatment even with a large amount of resin, we were able to keep the heat generation during curing within 30°C.

The aldol reaction progresses under the influence of temperature, humidity, and light! Example of impurity analysis in ethanol and acetone.

  • Analytical Equipment and Devices
  • Contract Analysis
  • Other contract services

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration
?chemical analysis.png

Chemical Analysis Concierge Service

We would like to introduce our "Chemical Analysis - Trust Us Service." When conducting component analysis of foreign substances or stains on products, it can be challenging to determine whether organic analysis or inorganic analysis is more suitable, and which specific analysis within organic or inorganic is the most appropriate. We provide a comprehensive service for customers who are struggling with the selection of analysis methods. Since each analysis device can measure different targets, it is necessary to choose a method that fits the purpose based on the information available.

If any issues arise, detailed analysis will also be provided! A simplified analysis for customers considering the introduction of overseas LCDs.

  • Analysis Services

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration
画像5.png

Observation of Conductive Particle Shape in COG Implementation

We will introduce the observation of the shape of conductive particles in COG implementation. ICs and liquid crystal panels are implemented using the COG method with ACF (anisotropic conductive film). A resin ball is used as the core, and a metal layer (such as nickel or gold) for conductivity is deposited on its surface. During connection, the particles deform appropriately to electrically connect the IC and the panel. To confirm the degree of particle deformation and connection status, cross-sectional observations were conducted, revealing that the particle deformation was at a "medium" level, indicating an appropriate degree of deformation. By examining the deformation of conductive particles from both the planar and cross-sectional directions, we can explore the correlation with display defects. Please feel free to contact us for any inquiries regarding panel-related defects.

Filter

classification
Delivery Time
Location