List of Other Amplification/PCR products
- classification:Other Amplification/PCR
1~45 item / All 46 items
We provide comprehensive support from design to manufacturing and maintenance!
- Contract manufacturing
It won't break even after 1 million repetitions! A mat switch with reliable operation, high durability, and low price. Suitable for options in machine tools as well. Please consult us about delivery t...
- Sensors
Electronically control the beam radiation direction! High-precision tag identification for each process.
- antenna
- Entrance and exit control system
- Other Amplification/PCR
What is an anechoic chamber? Is it really necessary?
An anechoic chamber is a "special room" used to test the performance and safety of wireless devices. In a regular room, invisible waves from smartphones, Wi-Fi, and televisions are present, making it impossible to conduct accurate tests on devices. Therefore, an anechoic chamber is a special space that "completely shuts out external waves" and also ensures that "waves inside do not leak outside." When is it used? - Testing and inspection of wireless devices - Testing for obtaining technical standard conformity certification (Giteki) - Confirming that there is no interference from waves to other devices In other words, it is "an essential place for creating accurate and reliable wireless devices." What is the inside of the room like? - The walls, ceiling, and floor are covered with "sponge-like materials that absorb waves (wave-absorbing panels)." - The entire room is covered with a metal shield to prevent external waves from entering. Why is it so important? Wireless devices can significantly impact medical equipment, airplanes, and fire department radios, depending on where they are used. That is why it is crucial to thoroughly verify that they emit waves correctly and safely in a place free from external influences, which is the anechoic chamber.
NTP is also 100% chemically synthesized!
- Other Amplification/PCR
We have achieved 100% chemical synthesis of dNTP using our proprietary phosphorylation technology.
- Other Amplification/PCR
Rapid and simple identification of strains, for hospital infection control! A PCR kit that allows for easy molecular epidemiological analysis in about 4 hours.
- Other Amplification/PCR
- Other Nucleic Acid/DNA Research
- Microbiology
A PCR kit that can detect drug resistance genes (β-lactamase) simultaneously using multiplex PCR.
- Other Amplification/PCR
- Other Nucleic Acid/DNA Research
- Microbiology
Over 500 real-time PCR/conventional PCR kits for pathogenic bacteria, viruses, veterinary medicine, allergens, GMOs, halal testing, etc.
- Real-time PCR
- Other Amplification/PCR
- Microbiology
Simultaneous detection of the main five types of diarrheagenic Escherichia coli and the pathogenic genes related to E. albertii using multiplex PCR method.
- Other Amplification/PCR
- Other Nucleic Acid/DNA Research
- Microbiology
PCR kit capable of detecting bovine mycoplasma genes.
- Other Amplification/PCR
- Other Nucleic Acid/DNA Research
Promotes the extraction of miRNA by combining with an RNA nucleic acid purification kit using a spin column.
- RNA Purification Kit
- Other Amplification/PCR
Koshihikari-specific variety identification PCR kit - Quickly and easily identify Koshihikari! Speeding up the testing process.
- Other Amplification/PCR
- Other analytical and testing equipment
- Quality assurance support systems and services
Selective enrichment of bacterial and fungal DNA! Human DNA can be removed regardless of sample volume.
- Other Nucleic Acid/DNA Research
- Real-time PCR
- Other Amplification/PCR
Significantly improved sensitivity of fluorescence measurement! Achieving fast and accurate analysis with a flat cap.
- Other Amplification/PCR
- Microtubes
- Real-time PCR
The material is polypropylene! It is compatible with various thermal cyclers.
- Other Amplification/PCR
PCR tubes (single and 8-strip), PCR plates (96-well and 384-well), plate seals, 8-strip caps, silicone mats, etc.
- Other Amplification/PCR
For the preparation of solutions for secondary screening of protein crystallization!
- Automatic Dispensing Device
- Other Amplification/PCR
- Other Protein Research
This is a cotton swab made of polyester cotton with a good bacterial uptake rate.
- Other Amplification/PCR
- Other purification and extraction
- Other experimental consumables
Samples can be transported safely.
- Other purification and extraction
- Other Amplification/PCR
Just add the primer and template DNA! Nucleic acid amplification reagent (2× master mix) optimized for the LAMP method.
- Other Amplification/PCR
Testing for foodborne pathogens (for Campylobacter detection) in facilities for processing wild game or for secondary processing.
- Other Amplification/PCR
Testing for foodborne pathogens (for the detection of enterohemorrhagic E. coli) in facilities for processing wild birds and animals or in facilities for secondary processing.
- Other Amplification/PCR
Testing for foodborne pathogens (for the detection of Salmonella species) in facilities for processing wild birds and animals or in facilities conducting secondary processing.
- Other Amplification/PCR
A compact device that can perform gene amplification to detection in as little as 30 minutes [for a wide range of gene detection applications such as food and testing fields].
- Other Amplification/PCR
Provides absolute quantification of nucleic acids using advanced 6-color multiplexing.
- Other Amplification/PCR
Fully integrated fully automated multiplex digital PCR system.
- Other Amplification/PCR
Virus transport container with preservation solution
- Other Amplification/PCR
- Other transport machines and equipment
Bst DNA polymerase is an enzyme that can be used in the LAMP method. The LAMP method is a technique for amplifying and detecting target DNA or RNA in a short period of time.
- Other Amplification/PCR
DNA polymerase 96-7 is an enzyme that can be used in the LAMP method. The LAMP method is a technique for rapidly amplifying and detecting target DNA or RNA.
- Other Amplification/PCR
Csa DNA polymerase is an enzyme that can be used in the LAMP method. The LAMP method is a technique for amplifying and detecting target DNA or RNA in a short period of time.
- Other Amplification/PCR
It is possible to amplify DNA using various primers with enzymes suitable for PCR reactions.
- Other Amplification/PCR
- enzyme
An enzyme that combines low error rates and thermal stability.
- Other Amplification/PCR
- enzyme
This is an immunochromatographic strip that allows for the simple and rapid detection of PCR products.
- Other purification and extraction
- Other Amplification/PCR
It is made of a highly transparent silicone base and has been treated to be impermeable to water vapor.
- Other purification and extraction
- Other Amplification/PCR
Compact and high-speed! You can obtain the same results with the same protocol as renowned devices.
- Other purification and extraction
- Other Amplification/PCR
- PCR equipment
It is possible to carry out biochemical reactions at high temperatures while keeping the solution contained within the chip.
- Other purification and extraction
- Other Amplification/PCR