We have compiled a list of manufacturers, distributors, product information, reference prices, and rankings for Analytical Equipment.
ipros is IPROS GMS IPROS One of the largest technical database sites in Japan that collects information on.

Analytical Equipment Product List and Ranking from 266 Manufacturers, Suppliers and Companies

Last Updated: Aggregation Period:Oct 22, 2025~Nov 18, 2025
This ranking is based on the number of page views on our site.

Analytical Equipment Manufacturer, Suppliers and Company Rankings

Last Updated: Aggregation Period:Oct 22, 2025~Nov 18, 2025
This ranking is based on the number of page views on our site.

  1. 一般財団法人材料科学技術振興財団 MST Tokyo//Testing, Analysis and Measurement
  2. ライフィクスアナリティカル Osaka//Pharmaceuticals and Biotechnology
  3. null/null
  4. 4 ビーエルテック Tokyo//Testing, Analysis and Measurement
  5. 5 サーモフィッシャーサイエンティフィック株式会社/Thermo Fisher Scientific K.K. Tokyo//Testing, Analysis and Measurement

Analytical Equipment Product ranking

Last Updated: Aggregation Period:Oct 22, 2025~Nov 18, 2025
This ranking is based on the number of page views on our site.

  1. Nanoparticle analysis device "TaylorSizer" ライフィクスアナリティカル
  2. iCAP PRO Series ICP Emission Spectrometer サーモフィッシャーサイエンティフィック株式会社/Thermo Fisher Scientific K.K.
  3. Alcohol analysis device for sake Alcolyzer3001 SAKE
  4. 4 Sake FT-IR component analysis device "OenoFoss2"
  5. 5 Trace Sulfur Analysis Device (Old Type) 日東精工アナリテック

Analytical Equipment Product List

451~465 item / All 1224 items

Displayed results

Application Data: Example of Erythromycin Impurity Analysis

Using the 'Solnac Tube' deionization tube for LC/MS! The official pharmacopoeia detects at 215nm.

Erythromycin, one of the macrolide antibiotics that has applications for many infectious diseases such as respiratory and soft tissue infections, was analyzed using LC conditions with phosphate buffer as the sample. Due to its weak UV absorption, erythromycin requires detection at a low wavelength, and it is detected at 215 nm in the pharmacopoeia. For details on the conditions and analysis results, please download the catalog. 【LC Conditions (Partial)】 ■ Equipment: Agilent 1200 ■ Flow rate: 0.3 ml/min ■ Detector: UV (215 nm) ■ Sample: Erythromycin reagent 50 ppm solution ■ Injection volume: 5μL *For more details, please refer to the PDF document or feel free to contact us.

  • Tubes and hoses

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Application Data: Example of Sulfonamide Analysis

Using the desalting tube "Solnac Tube" for LC/MS! We were able to measure four types of sulfonamides.

Sulfa drugs are a group of chemotherapeutic agents based on sulfanilamide, used as veterinary pharmaceuticals. An example using phosphate buffer solution was included in Shiseido's application data, so I referred to that to consider the elution conditions. For details on the conditions and analysis results, please download the catalog. 【LC Conditions (Partial)】 ■ Equipment: Agilent 1200 ■ Flow rate: 0.3 ml/min ■ Detector: UV (215 nm) ■ Sample: Mixed solution of 4 types of sulfa drugs at 20 ppm ■ Injection volume: 4 μL *For more details, please refer to the PDF materials or feel free to contact us.

  • Tubes and hoses

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Application Data: Example of Analysis of Narijikus Acid

Example of analyzing nalidixic acid using a desalting tube "Solnac Tube" for LC/MS!

We conducted an analysis using nalidixic acid, a type of quinolone antibacterial agent, as the sample under LC conditions with phosphate buffer solution. The confirmation test described in the pharmacopoeia employs ultraviolet-visible spectrophotometry, but since there was an example using phosphate buffer solution in Shiseido's application data, we referred to that. For details on the conditions and analysis results, please download the catalog. 【LC Conditions (Partial)】 ■ Equipment: Agilent 1200 ■ Flow rate: 0.3 ml/min ■ Detector: UV (215 nm) ■ Sample: Nalidixic acid reagent 20 ppm solution ■ Injection volume: 2 μL *For more details, please refer to the PDF document or feel free to contact us.

  • Tubes and hoses

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Application Data: Example of Ionic Liquid Analysis: Application to Ion Pair Reagents

Used the desalting tube "Solnac Tube" for LC/MS! Conducted online LC/MS analysis.

Ionic liquids are defined as "salts composed solely of ions that are in a liquid state at temperatures below 100°C," and their development is expected to focus primarily on their use as electrolytes. The main ionic liquids are often analyzed using HPLC with elution solutions that contain ion-pair reagents such as sodium dodecyl sulfate (SDS), which has high polarity and weak UV absorption, allowing detection even at low wavelengths. Using imidazolium salts, which are one of the representative structures of ionic liquids, we conducted LC/MS analysis with an elution solution containing ammonium dodecyl sulfate. For details on the conditions and analysis results, please download the catalog. 【LC Conditions (Partial)】 ■ Equipment: Agilent 1200 ■ Flow rate: 0.3 ml/min ■ Detector: UV (215 nm) ■ Sample: 5 ppm solution of 1-butyl-3-methylimidazolium chloride ■ Injection volume: 5 μL *For more details, please refer to the PDF document or feel free to contact us.

  • Tubes and hoses

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Application Data: Example of Negative Ion Measurement by TFA Removal (2)

Using the desalting tube "Sornak Tube" for LC/MS! The effect of TFA removal allows for signal detection.

When analyzing acidic compounds using reversed-phase partition chromatography, an acidic mobile phase (set to a pH that is at least 2 lower than the pKa of the analyte) may be used to suppress dissociation. Common acidic mobile phases suitable for use in LC/MS include acetic acid, formic acid, and trifluoroacetic acid (TFA). While TFA is appropriate for use at low pH, it is believed to cause ionization suppression with nearly 100% probability when detecting the analyte as a negative ion. Using methionine, an amino acid with acidic groups and high polarity, as the sample, TFA was removed from the eluent using a Sorbent tube, and negative ion measurements were conducted. For details on conditions and analysis results, please download the catalog. 【LC Conditions (Partial)】 ■ Equipment: Agilent 1200 ■ Flow rate: 0.3 ml/min ■ Detector: UV (210 nm) ■ Sample: Methionine 20 ppm solution ■ Injection volume: 5 μL *For more details, please refer to the PDF document or feel free to contact us.

  • Tubes and hoses

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Application Data] Examples of improvements for easily adsorbed basic compounds

An example of improvement using post-column method for basic compounds that easily adsorb to the Sornak tube!

When using the Solnack tube CFAN under phosphate buffer conditions, if the compound being measured is basic, it may become dissociated and adsorb to the resin inside the tube. Therefore, by adding ammonia water using the post-column method before introducing the tube, we thought that making the eluent inside the tube basic and keeping the target compound in its non-dissociated form could suppress adsorption. We attempted to improve adsorption to the Solnack tube by adding ammonia water using the post-column method. For details on conditions and analysis results, please download the catalog. 【LC Conditions (Partial)】 ■ Equipment: Agilent 1200 ■ Detector: UV (215 nm) ■ Sample: 20 ppm solution of hydrochloride doxepin reagent ■ Injection volume: 5 μL ■ Post-column: 200 mM ammonia water at 0.05 ml/min *For more details, please refer to the PDF document or feel free to contact us.

  • Tubes and hoses

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Application Data: Example of LC/MS Measurement by Decyl Sulfate Removal

Using the desalting tube "Solnac Tube" for LC/MS! Online removal of dodecyl sulfate.

When analyzing highly polar basic compounds using reversed-phase partition chromatography, adding acidic ionic species to the eluent can enhance retention by forming neutral ion pairs through ionic bonding. Sodium dodecyl sulfate, used as an ion-pairing reagent, is non-volatile and can precipitate in the ionization section of the MS, making it difficult to introduce, and it can suppress the ionization of the analytes, thus it cannot be used for online LC/MS measurements. In this case, we used a system with ammonium dodecyl sulfate (ADS) added, using caffeine and thiamine hydrochloride as samples, and removed dodecyl sulfate from the sample solution using a Solnack tube to perform positive ion measurements. For details on the conditions and analysis results, please download the catalog. 【Infusion Conditions】 ■Samples: (1) Caffeine 10 ppm solution, (2) Thiamine hydrochloride 10 ppm solution ■Solvent: CH3CN / H2O = 50 / 50 + 10 mM Ammonium dodecyl sulfate ■Flow rate: 0.1 ml/min *For more details, please refer to the PDF document or feel free to contact us.

  • Tubes and hoses

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Trace Biological Sample Analysis Device 'HTEC-510'

It's small but all-in-one! ECD measurement is difficult... Good news for researchers who have such concerns.

The "HTEC-510" is a micro-sample analysis device that enables easy operation with a centralized control panel. It is equipped with a high-sensitivity ECD amplifier, degasser, column thermostat, and a centralized control panel. The integrated housing requires a footprint similar to that of B4 paper, eliminating the need for cumbersome piping work. Additionally, the inert design enhances stability during measurements (compared to our previous models). 【Features】 ■ Ultra-high sensitivity ■ High stability ■ Minimal maintenance requirements, resulting in very high operational rates ■ Compact and space-saving ■ Intuitive operability from a single display *For more details, please refer to the PDF materials or feel free to contact us.

  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Strongly supports problem-solving in mass analysis.

We propose outsourcing services related to mass spectrometry!

Are you having trouble with the evaluation and analysis of samples using mass spectrometry? Our company offers outsourcing services related to mass spectrometry. Veteran consultants with over 25 years of experience in equipment development and applied research will provide strong support in terms of analytical techniques, expertise, experience, and know-how. We will fully support your company's problem-solving related to LC/MS. [Support Overview] ■ Contract analysis using Solnac ■ Dispatch of lecturers for in-house seminars ■ Contract analysis *For more details, please refer to the PDF document or feel free to contact us.

  • tube

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Energy Dispersive Fluorescence X-ray Analyzer / Desktop Type C-Cite

It is a tabletop energy-dispersive X-ray fluorescence analyzer equipped with basic performance features.

<Features> - Non-destructive elemental analysis from Na (11) to U (92) - 6 types of customizable filters - Compact design - Equipped with sample camera - Sample tray (8/16 positions) - Silicon drift detector (SDD)

  • X-ray fluorescence analyzer

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Energy Dispersive Fluorescence X-ray Analyzer / Desktop Type X-Calibur

It is a compact and high-performance desktop energy-dispersive X-ray fluorescence analyzer.

<Features> - Non-destructive elemental analysis from Na (11) to U (92) - 6 types of customizable tube filters - Sample tray (8/16 positions) - Silicon drift (up to 125 eV) - Unique front design - Compact shape - Equipped with a sample camera

  • X-ray fluorescence analyzer

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Energy-dispersive fluorescent X-ray analysis device / Laboratory use Nova

High-performance laboratory system

<Features> - Non-destructive elemental analysis Na(11) to U(92) - Silicon drift detector (up to 125 eV) - Improved peak/background ratio (when using secondary target excitation) - 8 types of filters, secondary target

  • X-ray fluorescence analyzer

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Energy Dispersive Fluorescence X-ray Analyzer / Laboratory Use Apollo

High-sensitivity analysis device for air quality

Apollo can conduct tests on inorganic air pollutants while supporting compliance with U.S. EPA air quality regulation requirements, and it is capable of quantifying particulate deposits in the air for up to 60 elements. Analysis can be performed without destroying the filter, and since no additional processing such as pretreatment is required, it is also possible to store air filter samples for future reference. <Features> - High sensitivity for particulate matter adhered to air filters - Support for compliance with U.S. EPA air quality regulation requirements - Non-destructive elemental analysis - Eight types of filters, secondary targets

  • X-ray fluorescence analyzer

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Ion contamination analysis device

The degree of contamination caused by ionic impurities in the air that occurs on electronic components is evaluated by measuring the amount of ions in the cleaning solution.

- The compounds in the solution are diverse, so we assume the ion species to be NaCl according to the standards and convert it to NaCl / cm². - The contamination level can be measured using the static method. - The measurement accuracy of the device is high, capable of measuring down to 0.0001 µS/cm level. - Simultaneously cleaning the parts and recycling the cleaning solution with an ion resin filter minimizes environmental pollution. - It complies with the following international standards: - Mil-P-28809 and Mil-STD-2000A (USA) - Defense Standard 10/03 (UK) - IPC-TR-583 - We offer three different cleaning tank capacities: 0.4L, 8L, and 40L. - It has a highly durable and easy-to-maintain structure.

  • Other measurement, recording and measuring instruments

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Energy-dispersive portable fluorescent X-ray analysis device 'P-Metrix'

Equipped with a touchscreen! Can be connected to Mini HDMI, SSD, USB, and more.

"P-Metrix" is a cost-effective portable fluorescent X-ray analysis device. It features a direct method with a choice of seven types of tube filters. It is equipped with a sample chamber in a spacious testing room. It excels in safety with self-maintenance and portability. 【Features】 ■ Non-destructive elemental analysis (elemental analysis from Na[11] to U[92], ppm-100%) ■ Silicon drift detector (up to 125 eV / excellent energy resolution) ■ Easy component replacement ■ High performance with 50 kV, 10 W, and Rh electrode included ■ Automatic calibration function, seven types of tube filters *For more details, please refer to the PDF document or feel free to contact us.

  • X-ray fluorescence analyzer

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration