Greenhouse gas concentration analyzer
Simultaneous measurement of methane, carbon dioxide, and water vapor.
- Ideal for measurements during movement and in the field - Wide measurement range
- Company:レスター システムビジネスユニット
- Price:Other
Last Updated: Aggregation Period:Jul 23, 2025~Aug 19, 2025
This ranking is based on the number of page views on our site.
Last Updated: Aggregation Period:Jul 23, 2025~Aug 19, 2025
This ranking is based on the number of page views on our site.
Last Updated: Aggregation Period:Jul 23, 2025~Aug 19, 2025
This ranking is based on the number of page views on our site.
166~180 item / All 358 items
Simultaneous measurement of methane, carbon dioxide, and water vapor.
- Ideal for measurements during movement and in the field - Wide measurement range
Simultaneous measurement of methane, nitrous oxide, and water vapor.
- High precision (0.1 ppb in 1 second measurement: N2O) - Wide measurement range, high sensitivity - Measurement rate: up to 10 Hz
Simultaneous measurement of hydrochloric acid and hydrofluoric acid.
- Accuracy (100 seconds) HCl: < 0.1 ppb HF: < 0.05 ppb - Measurement Range HCl: 0.3 to 2,000 ppb HF: 0.3 to 2,000 ppb - Response Time: < 2 seconds (when using external pump N920)
GC-FID for automatic continuous monitoring in the atmosphere, water, and soil.
airmoVOC BTEX is a gas chromatograph with FID that can measure and monitor trace amounts of benzene, toluene, ethylbenzene, and (m-/p-/o-) xylene.
Daily, the analysis of magnetic waveforms is continuously sought. Everything begins here. The same values for anyone, anytime - a commitment to reproducibility.
The MAD-310RAS is equipped with a memory function for X, Y, and Z axis coordinates, pursuing reproducibility so that anyone can obtain the same measurement values at any time. It can also use our proprietary ultra-fine probe F-075 (width 0.6mm × thickness 0.28mm), which excels in proximity measurement of magnetic flux. ● Easy positioning of the slider using a jog dial 0.01mm/0.05mm/0.1mm step ● Memory function for X, Y, Z coordinates, capable of programmed measurements ● Point auto function ● Frequency analysis function (patented) ● Skew angle measurement capability (patented) ● Maximum rotational angle resolution of 43,200p/rev ● Automatic movement up to 200mm, with a maximum resolution of 0.01mm ● 2D editing function (two-dimensional) ● Data transfer to spreadsheet software ● ASCII output calculation ● Vector measurement and analysis (optional) ● The ultra-fine probe F-075 (width 0.6mm × thickness 0.28mm) can be used.
Real-time dynamic particle image analysis - Entering a deeper world of material analysis with particle images and particle shape data through dynamic imaging methods.
Hydro Insight is designed to be used with the particle size distribution measurement device MasterSizer 3000, providing particle images and particle shape data that complement the particle size data obtained from laser diffraction. ● It is a new measurement unit that combines the dynamic imaging expertise of Vision Analytical with the dispersion and flow knowledge of Malvern Panalytical. ● It can acquire individual particle images and 30 types of particle shape parameters simultaneously with the particle size distribution measurement of the MasterSizer. ● In addition to traditional particle size distribution, it allows for the acquisition of detailed particle shape information, revealing a new aspect of the particles. 【Features of Hydro Insight】 ● High-speed, high-resolution dynamic imaging technology Digital camera with 127 frames per second and a resolution of up to 5 megapixels ● Imaging of individual particles and liquid particle dispersions ● Thumbnail image storage ● Acquisition of quantitative data It is possible to obtain quantitative data regarding particle size and shape, such as width and aspect ratio. ● Integration of laser diffraction workflow It allows for the rapid acquisition of shape information for many particles simultaneously with laser diffraction measurements.
The PPA55x1 series fully complies with advanced standards for harmonic and flicker response.
■The latest harmonic and flicker measurement compliant with the unique IEC61000-3-2/3 standards in its class - New measuring instruments are essential for developing products that comply with the IEC standards in this field, which change year by year. The new standards are as follows: - IEC61000-3-2/3 Harmonics (IEC61000-3-2:2006+A2:2009, IEC61000-4-7:2002 + A1:2009) Flicker (IEC61000-3-3:2013, IEC61000-4-15:2011) The PPA55x1 series supports the only full compliance testing in its class and significantly contributes to the development of equipment for export to the global market. The PPA4500 series undergoes ISO17025 calibration. Calibration compliant with UKAS is conducted by Newtons4th in the UK. ■Consistent high-speed sampling at 2.2MS/s and reliable harmonic measurement over a wide bandwidth of 1MHz With consistent high-speed sampling at 2.2MS/s and a wide bandwidth of 1MHz maintained in all modes, it is possible to accurately capture power that includes harmonics.
A space-saving bench-type device that can obtain not only two-dimensional data but also three-dimensional data.
This device is an angular spectral color measurement device that can measure colors that change depending on the direction of incident light and the viewing angle, as a spatial distribution of reflected or transmitted light. It is also capable of measuring object colors and light source colors.
Disk Drive Analyzer DDA 7Zi-A Series
The DDA 7Zi-A series is a dedicated model that comes standard with hard disk analysis tools in the WavePro 7Zi-A series. ● Bandwidth: 3.5GHz, 6GHz [Bandwidth upgrade available] ● Memory: 32M points to a maximum of 256M points (2ch) ● Sampling rate: 20GS/s to 40GS/s (2ch) ● 80-bit serial pattern trigger (optional) ● Hard disk analysis function ● Serial data analysis function (equivalent to the SDA 7Zi-A series)
The SPARQ signal integrity network analyzer allows for easy S-parameter measurements at a lower cost compared to a VNA.
The SPARQ Signal Integrity Network Analyzer allows for quick and easy S-parameter measurements at a lower cost compared to a VNA. Calibrated measurement data can be obtained in just a few minutes, without the need to reconnect cables or connect to a standard calibration kit or ECAL (Electronic Calibration Module) during that time.
Since it can be driven in dual channel mode, two spectra can be compared and evaluated.
Coherent Solutions' 1550nm high-speed spectrum analyzer (OSA150D) measures spectra with high resolution. Utilizing Fabry-Perot etalon technology, it can perform measurements in a short time with a high scanning rate of over 20Hz. Additionally, it can be driven in dual-channel mode, allowing for comparative evaluation of two spectra. 【Features】 ○ Wavelength range: 1520-1580nm ○ Bandpass resolution: 3.5GHz (28pm) ○ Wavelength accuracy: 50pm (C-band only) ○ Sensitivity: <-60dBm ○ Polarization sensitivity: <0.3dB For more details, please contact us or download the catalog. *This catalog is in English.