We have compiled a list of manufacturers, distributors, product information, reference prices, and rankings for column.
ipros is IPROS GMS IPROS One of the largest technical database sites in Japan that collects information on.

column Product List and Ranking from 29 Manufacturers, Suppliers and Companies

Last Updated: Aggregation Period:Jul 23, 2025~Aug 19, 2025
This ranking is based on the number of page views on our site.

column Manufacturer, Suppliers and Company Rankings

Last Updated: Aggregation Period:Jul 23, 2025~Aug 19, 2025
This ranking is based on the number of page views on our site.

  1. null/null
  2. null/null
  3. アジレント・テクノロジー株式会社 Tokyo//Testing, Analysis and Measurement
  4. 4 null/null
  5. 5 null/null

column Product ranking

Last Updated: Aggregation Period:Jul 23, 2025~Aug 19, 2025
This ranking is based on the number of page views on our site.

  1. Innovative solid-phase extraction column Oasis PRiME HLB
  2. ACQUITY UPLC column
  3. High Purity Silica Gel HPLC Column "Mightysil Series"
  4. 4 Screening/Purification Prepackaged Column SkillPak Series
  5. 5 HPLC Column "GPC Column - Molecular Weight Marker"

column Product List

511~525 item / All 593 items

Displayed results

ACE C18-PFP HPLC column

HPLC column with pentafluorophenyl (PFP) group bonded to C18 phase.

This is an HPLC column developed by ACT in the UK, combining C18 with a PFP group. By integrating the PFP phase, which provides complementary selectivity to conventional C18, it improves the separation of polar basic substances and demonstrates selective characteristics for halogenated aromatic compounds and positional isomers. Additionally, the C18-PFP phase possesses multiple separation mechanisms (hydrophobic, π-π, hydrogen bonding, shape selectivity), showcasing its capabilities for mixtures that are difficult or impossible to separate with conventional C18. **Features** - A mixed column that combines C18 and PFP (PentaFluoroPhenyl) phases - Enhanced separation capability for polar basic substances - "Ultra-inert & Ultra-pure silica" essential for peak shape and reproducibility - Excellent stability for temperature programming analysis - Optimal for UV and LC/MS due to ultra-low bleed characteristics

  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Trap column "OPTI-TRAP"

Syringe road / elution or available online! Bio-compatible specification trap column.

The "OPTI-TRAP" is a cartridge-type trap column that enables the purification and concentration of samples. It comes in a capillary type made of PEEK (0.5μL) and a durable stainless steel version (with a PEEK flow path), both designed to be fully biocompatible with titanium frits. It is equipped with a color ID band that allows for material identification. 【Features】 ■ Hand-tightened pressure resistance: 1,500 psi (100 bar) ■ Low back pressure, usable with syringe load/elution or online ■ Convenient bi-directional cartridge for cleaning and regeneration ■ Color ID band for material identification *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Roc C8 HPLC column (USP L7)

Solid high reliability – provides the peak shape, reproducibility, robustness, and separation performance desired by users.

The Roc C8 HPLC column (USP L7) is designed to become a "standard" in LC analysis laboratories. These robust and highly reliable columns are compatible with HPLC systems that can withstand pressures up to 40 MPa, providing users with the desired peak shape, reproducibility, robustness, and separation performance for all LC applications. Their exceptional utility maximizes operational efficiency. The minimal package design allows for compact storage. 【Features】 ■ Designed to be a "standard" in LC analysis laboratories, this standard HPLC column is compatible with HPLC systems that can withstand pressures up to 40 MPa. ■ Solid high reliability – provides users with the desired peak shape, reproducibility, robustness, and separation performance. ■ Exceptional utility capable of handling a large volume of analytical tasks – diverse packing materials using high-purity silica backed by high-quality manufacturing processes are suitable for most HPLC methods. *This catalog is in English. *For more details, please download the PDF or contact us.

  • Contract manufacturing

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Raptor LC Column

A variety of stationary phases and particle sizes! LC columns with better selectivity that improve separation efficiency.

Restek's "Raptor LC Column" is a highly efficient LC column that significantly reduces analysis time. It includes options suitable for biological sample analysis, such as the "Raptor Biphenyl Column" for drug and metabolite analysis, as well as the "Raptor ARC-18 Column." It offers better selectivity that improves resolution and sustainable reproducibility. 【Features】 ■ High efficiency that significantly reduces analysis time ■ Better selectivity that improves resolution ■ Improved sample throughput with existing HPLC and UHPLC ■ Sustainable reproducibility ■ A variety of stationary phases and particle sizes *For more details, please refer to the PDF document or feel free to contact us.

  • Other inspection equipment and devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Rxi-SVOCms column

Capture semi-volatile compounds clearly with robustness and reliability! Achieve stable performance.

The "Rxi-SVOCms Column" is a product specially designed for the analysis of semi-volatile compounds. With new polymers and inert treatment chemistry, it achieves an inert column with strictly controlled selectivity, demonstrating outstanding performance across a wide range of analytes (acidic, basic, neutral). It allows for a long-lasting calibration curve, enabling the execution of many samples before requiring instrument recalibration or column replacement. 【Features】 ■ Exceptional inertness, allowing for continuous calibration curve creation and sample analysis ■ Improved accuracy due to excellent separation capability of critical pairs ■ Consistent performance between columns ■ Long column lifespan *For more details, please refer to the PDF document or feel free to contact us.

  • Other machine elements

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Force Performance LC Column

Restek's 100% pure satisfaction guarantee! Compatible with high-pressure fast analysis using UHPLC.

Restek's "Force Performance LC Column" is a product that can increase productivity by maximizing the operating time of the equipment. It is designed to easily transfer methods from HPLC to advanced UHPLC and to withstand high pressure and severe pressure fluctuations. Whether using columns with particle sizes of 3μm or 5μm in a typical HPLC system, or using columns with a particle size of 1.8μm in a new UHPLC, it consistently provides the same separation. 【Features】 ■ Durability and reproducibility ■ Compatibility between HPLC and UHPLC ■ High quality *For more details, please refer to the PDF document or feel free to contact us.

  • Other machine elements

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Rxi-PAH GC Column

Important for food safety! Separation of isobaric polycyclic aromatic hydrocarbons.

The "Rxi-PAH GC Column" is a product designed by Restek that can uniquely separate polycyclic aromatic hydrocarbons (PAHs), which are important for food safety and cannot be separated by mass spectrometry, thanks to its high phenyl content stationary phase. It can easily separate difficult target substances like PAH4 from the European Food Safety Authority (EFSA) and allows for accurate quantification. You can achieve results that are not possible with general GC columns. 【Features】 ■ Separation of all EFSA PAH4 compounds ■ Suitable separation of chrysene from interfering PAHs ■ Complete separation of benzo[b], [k], [j], and [a] fluoranthene ■ 360℃ thermal stability ■ Analysis of low-volatility dibenzopyrene is possible *For more details, please refer to the PDF materials or feel free to contact us.

  • Other machine elements

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Liquid Chromatography (LC) Column - Usage and Handling

Individually filled, ensuring excellent performance! Detailed introduction on installation and more.

This document explains how to use and handle Restek liquid chromatography (LC) columns. Restek liquid chromatography (LC) columns are individually packed and tested to ensure excellent performance. It includes information on column hardware, installation and use of columns, and column maintenance. We encourage you to read it. 【Contents (partial)】 ■ Analytical column test report ■ Column hardware ■ Installation and use of columns ■ Column maintenance ■ Column cleaning and storage *For more details, please refer to the PDF document or feel free to contact us.

  • Technical and Reference Books

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Speeding up the analysis of multi-residue pesticides in food using LPGC-MS.

It is possible to achieve the speed that is an advantage of LPGC-MS with a simple column change!

This document provides an explanation of pesticide analysis in strawberries using LPGC-MS. The analysis of multi-component pesticide residues is essential for food safety testing, and laboratories are typically required to balance a large number of samples with a quick turnaround time. In addition to the explanation of LPGC-MS pesticide analysis, it also includes featured products, making it a useful reference. We encourage you to read it. 【Featured Products (partial)】 ■ Low-Pressure GC (LPGC) Column Kit ■ GC Multiresidue Pesticide Kit ■ Q-sep QuEChERS dSPE Tubes for Extract Cleanup ■ Q-sep QuEChERS Extraction Salts ■ Topaz GC Inlet Liners *For more details, please refer to the PDF document or feel free to contact us.

  • Technical and Reference Books

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Information] PLOT Column User Manual

A detailed explanation of the installation method until you are ready to use the column!

This document serves as the instruction manual for the PLOT column. It includes installation methods until the column is ready for use, as well as useful tips on temperature limits and column regeneration. Each process is explained in detail, making it a handy reference for product usage. We encourage you to read it. 【Contents (partial)】 ■ Installation methods ■ Useful tips - Temperature limits - Column regeneration - Protection from particles *For more details, please refer to the PDF document or feel free to contact us.

  • Technical and Reference Books

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Raptor Polar X

Enhanced selectivity! Separation of a wide range of polar compounds using a new hybrid stationary phase.

The "Raptor Polar X" is a column specially designed to selectively retain polar analytes through a balance of two retention mechanisms. When combined with a mass spectrometer, it is ideal for analyzing a wide variety of polar compounds. The separation capability of this product simplifies the analysis of polar compounds. It can reliably retain a wide range of polar analytes and efficiently separate them. Please feel free to contact us if you have any inquiries. 【Features】 ■ No need for time-consuming derivatization or ion-pair formation ■ Switch retention modes with simple mobile phase changes and short equilibration times ■ Suitable for enhancing sensitivity and selectivity in LC-MS analysis ■ Excellent separation and resolution of a wide variety of polar compounds ■ Combines HILIC and ion-exchange retention mechanisms into a single ligand ■ Widely applicable to the analysis of polar compounds across different fields and methods *For more details, please refer to the PDF document or feel free to contact us.

  • Separation device

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Inert LC Columns

Improve peak shape without using additives! Achieve high precision and throughput.

We would like to introduce our "Inert LC Column." We offer two products: Raptor Inert Biphenyl HPLC Columns and Raptor Inert ARC-18 HPLC Columns. There is no need for time-consuming conditioning or complex passivation. Additionally, the response and recovery rates of analytes are improved, lowering the detection limits. 【Four Benefits】 ■ Improved peak shape without using passivation or additives in the mobile phase ■ Enhanced response and recovery rates of analytes, resulting in lower detection limits ■ Minimization of variability in analytical results, achieving high precision and throughput ■ Elimination of the need for time-consuming conditioning and complex passivation *For more details, please refer to the PDF document or feel free to contact us.

  • Coating Agent

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Agilent GPC/SEC column Polymer Standard

Agilent's GPC/SEC columns and polymer standards are sold and supported by AMR.

At AMR, we are a partner company of Agilent Technologies, providing sales and support for Agilent's GPC/SEC products. To accommodate various polymer analyses, we offer a wide range of molecular weight fractionation and columns and polymer standards suitable for both aqueous and organic solvents. 【Features】 ■ A lineup of columns compatible with organic solvents, mixed solvents, aqueous solutions, and polar solvents. ■ The "PLgel" series includes organic solvent-based columns that can handle pH levels from 1 to 14, covering a molecular weight range of up to 10 million. ■ The "POLARGEL" series is ideal for polymer analysis with polar functional groups, compatible with polar organic solvents such as THF, DMSO, NMP, DMAc, DMF, and mixed solvents of water and organic solvents. ■ For the analysis of water-soluble polymers, we offer the polymer-based filler "PL AQUAGEL" or the silica-based filler "INFINITYLAB PL MULTISOLVENT." ■ The "EasiVial" and "EasiCal" kits complete calibration in three simple steps. *For more details, please refer to the PDF document or feel free to contact us.

  • Column Chromatography

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Nano UHPLC column "Aurora Generation 3"

Improved separation energy, throughput, and reproducibility with the nanoZero and emitter-integrated structure achieving zero dead volume.

"Aurora Generation 3" is a nano UHPLC column that can bind more peptides, allowing for excellent identification results with high separation capability even with a smaller sample volume. Additionally, the unique "nanoZero" design eliminates dead volume and achieves high pressure resistance of over 1,700 bar. The emitter-integrated column design provides improved longevity and spray stability, even between different columns and manufacturing batches, resulting in enhanced column lifespan. 【Features】 ■ Improved separation capability with the newly adopted 1.7μm particle size C18 stationary phase ■ Increased pressure resistance due to improvements in nanoZero fittings ■ Enhanced spray stability and column lifespan through improvements in the emitter-integrated design *For more details, please download the PDF or feel free to contact us.

  • Other experimental equipment and supplies

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

HPLC/UHPLC column "FlexFire WP C4"

For the analysis of macromolecules such as proteins and antibodies! It greatly contributes to the analysis of biopharmaceuticals.

The "FlexFire WP C4" is a column designed to target macromolecules such as proteins and antibodies. To accommodate various analytical conditions, its pH and temperature durability have been significantly upgraded compared to previous models, greatly contributing to the analysis of biopharmaceuticals in the future. Additionally, it can also be applied to the analysis of intact mAbs, in addition to proteins. 【Features】 ■Elutes proteins with various properties based on hydrophobic differences, primarily aimed at analyzing primary structural characteristics. ■Applicable for the analysis of intact mAbs. ■Ensures durability at 80°C, allowing for sharp peak elution. *For more details, please refer to the PDF document or feel free to contact us.

  • Other protein analysis
  • Column Chromatography

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration