We have compiled a list of manufacturers, distributors, product information, reference prices, and rankings for Ion Chromatography.
ipros is IPROS GMS IPROS One of the largest technical database sites in Japan that collects information on.

Ion Chromatography Product List and Ranking from 8 Manufacturers, Suppliers and Companies

Last Updated: Aggregation Period:Sep 17, 2025~Oct 14, 2025
This ranking is based on the number of page views on our site.

Ion Chromatography Manufacturer, Suppliers and Company Rankings

Last Updated: Aggregation Period:Sep 17, 2025~Oct 14, 2025
This ranking is based on the number of page views on our site.

  1. メトロームジャパン 本社 Tokyo//Testing, Analysis and Measurement
  2. サーモフィッシャーサイエンティフィック株式会社/Thermo Fisher Scientific K.K. Tokyo//Testing, Analysis and Measurement
  3. 東ソー バイオサイエンス事業部 計測分野 Tokyo//Chemical
  4. 4 東亜ディーケーケー 本社、営業所(札幌・仙台・千葉・名古屋・大阪・広島・四国・北九州)、事業所(狭山、東大和) Tokyo//Testing, Analysis and Measurement
  5. 5 科健化学株式会社 Science and Health with Chemistry CO., LTD. Kanagawa//others

Ion Chromatography Product ranking

Last Updated: Aggregation Period:Sep 17, 2025~Oct 14, 2025
This ranking is based on the number of page views on our site.

  1. Ion Chromatograph "Dionex Integrion" サーモフィッシャーサイエンティフィック株式会社/Thermo Fisher Scientific K.K.
  2. Basics of Ion Chromatography: Eluent & Standard Solution Edition [Technical Document] メトロームジャパン 本社
  3. Ion Chromatograph "Dionex ICS-6000" サーモフィッシャーサイエンティフィック株式会社/Thermo Fisher Scientific K.K.
  4. Ion Chromatograph "Dionex Inuvion" サーモフィッシャーサイエンティフィック株式会社/Thermo Fisher Scientific K.K.
  5. 4 Basic Ion Chromatography: Advanced Applications [Technical Document] メトロームジャパン 本社

Ion Chromatography Product List

46~60 item / All 95 items

Displayed results

Measuring Zinc Oxide! Ion Chromatograph with Visible Absorbance Detection

Zinc oxide, which is contained in various cosmetics and pharmaceuticals/formulations, can be analyzed using ion chromatography.

◆Measurement of Zinc Oxide in Sunscreen Using Ion Chromatography with Visible Absorbance Detection◆ Sunscreens are classified as over-the-counter (OTC) drugs in the United States, and zinc oxide is one of the active ingredients that has received approval from the U.S. Food and Drug Administration (FDA) for use in sunscreens (with a maximum concentration of 25%). Zinc oxide is a powdered mineral that adheres to the outermost layer of the skin, acting as a broad-spectrum blocking agent that scatters, reflects, and absorbs ultraviolet radiation, providing protection from both UVA and UVB radiation, making it unique among sunscreen ingredients. The United States Pharmacopeia (USP) has developed monographs for FDA-approved drugs, including OTC medications, and is working to obtain the necessary information to maintain high-quality pharmaceuticals. It has also initiated a global effort to update many existing monographs across all official methods. As part of this USP initiative, the addition of an ion chromatography (IC) method for zinc measurement in General Chapter <591> is proposed. This method will serve as an alternative to the existing titration-based analytical methods in the monographs for zinc-containing pharmaceuticals. *Please download from the catalog at the bottom of the page.*

  • cover.png
  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Ion chromatography is Thermo Fisher Scientific.

The ion chromatograph, equipped with the three pillars of performance, results, and support, is from Thermo Fisher Scientific!

■Sales Performance Boasting Top Market Share■ Since starting sales of ion chromatography in Japan in 1975, we have pursued ease of use and have delivered over 4,000 units nationwide. We boast a market share of over 65%. *Source: R&D Corporation, Scientific Instruments Yearbook ■High-Level Customer Support System■ To ensure that our equipment can be used stably and for a long time, we collaborate with sales agents nationwide and have over 90 certified service engineers. Additionally, technical support is available from resident engineers, allowing you to use our products with peace of mind. ■Reliable Technical Expertise Supporting Analysts and Labs■ Advanced technologies such as a mobile phase generator capable of automatic generation of elution solutions and suppressors contribute to the efficiency of lab operations. We offer over 90 types of columns for ion chromatography.

  • ics-6000.jpg
  • ic-integrion.jpg
  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Upgrade to the dissolution liquid generator system! Achieving high efficiency!

Upgraded to an eluent generator system for ion chromatography, achieving improved productivity and high efficiency in the lab!

"Are you spending too much time preparing elution solutions?" "Wouldn't you like to aim for the accurate generation of elution solutions?" "Are you having trouble with condition considerations?" The Thermo Scientific Dionex Integrion RFIC Ion Chromatography System, known for its ease of use and proven delivery numbers, will solve these concerns. 【This is the optimal solution for customers with the following challenges】 - Want to shorten the time for elution solution preparation - Want to eliminate peak overlaps in carbonate anion analysis and gain confidence in component identification - Want to analyze anions and organic acids in a single analysis - Want to conduct analysis of amines - Want to reduce analysis time Currently, users of the Dionex Integrion with carbonate systems can upgrade.

  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Setting of gradient conditions for ion chromatography

Thorough explanation of how to set gradient conditions! It will provide hints for improving separation.

Generally, isocratic conditions are used for elution in ion chromatography; however, when analyzing diverse ionic species, separation can be difficult and may not be achievable under isocratic elution conditions. In such cases, using hydroxide ions and performing gradient analysis with a concentration gradient can improve separation. Gradient analysis is a method that enhances separation by increasing the concentration of the eluent from low to high during the analysis, allowing components that are retained more easily to elute faster. We will introduce examples of the separation of inorganic anions and organic acids regarding the separation of ionic species due to changes in eluent concentration and the setting of gradient conditions. By using an eluent generator system, it is possible to supply accurate and high-purity eluent simply by sending ultrapure water. Additionally, gradient analysis can be easily performed with just the concentration settings from the workstation. Furthermore, the Thermo Scientific Virtual Column Separation Simulator can generate virtual chromatograms under gradient conditions online. Please utilize it for examining analytical conditions.

  • グラジエント.PNG
  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Ion Chromatography Analysis Case (Solid Surface)

Suitable for relative comparison of flat samples such as printed circuit boards! Introducing the analysis flow of liquid samples and solid surfaces.

We would like to introduce a case study of ion chromatography analysis conducted by our company (solid surfaces). Solid surfaces can also be measured using ion chromatography by extracting them into a solution. Additionally, average data can be obtained for sample surfaces larger than a few centimeters, making it suitable for relative comparisons of flat samples such as printed circuit boards. You can view the analysis flow for liquid samples and solid surfaces by downloading the PDF below. 【Overview of Liquid Sample Analysis】 ■ Liquid samples are introduced into the device for measurement after solution preparation such as dilution and filtration. ■ Measurement results are reported in solution concentration [mg/L]. *For more details, please refer to the PDF document or feel free to contact us.

  • IC_装置.png
  • Other contract services

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Analysis of eluted components from printed circuit boards.

It is possible to analyze cation components in liquid samples.

As electronic devices are increasingly used in various everyday locations, ensuring the reliability of products has become important. Since it is possible for the copper used in the wiring of printed circuit boards to migrate and cause defects in high temperature and high humidity environments, it is crucial to evaluate the components that promote migration. This case study introduces an example of quantitative analysis of cation components eluted from printed circuit boards using ion chromatography (IC). Thus, IC is an effective method for evaluating the corrosion components on the surface of solid samples.

  • Contract Analysis

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Basic Ion Chromatography: Advanced Applications [Technical Document]

An introductory technical booklet explaining the question, "What can be measured with ion chromatography?"

It is described in a very easy-to-understand manner, so it can also be used as training material for beginners in ion chromatography. Additionally, many technical documents related to ion chromatography are available!

  • Other environmental analysis equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Basics of Ion Chromatography: Column Edition [Technical Document]

IC: Ion Chromatography - A beginner's technical booklet that provides an easy-to-understand explanation of the columns used in ion chromatography.

It can also be used as training material for those operating an ion chromatograph for the first time.

  • 948-6065.jpg
  • Ion Chromatography
  • Analytical Equipment and Devices
  • Other water quality analysis

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Technical Data: Basics of Ion Chromatography - Anion Analysis Edition

IC: Ion Chromatography A beginner-friendly technical booklet that clearly explains the analysis of anions using ion chromatography!

Content 1) Anion Analysis and Official Methods Content 2) Basic Operations and General Precautions for Anion Analysis Content 3) Measurement Examples of Anion Analysis

  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Technical Data: Measurement of Trace Cations in Lithium Hexafluorophosphate

IC: Ion Chromatography - Measurement of trace cations in LiPF6 electrolyte used in secondary batteries (batteries) using ion chromatography.

We present the results of measuring trace cations contained in lithium hexafluorophosphate (LiPF6), which is used as an electrolyte in secondary batteries (storage batteries), using ion chromatography. After continuous suppression of cations, trace cations in the sample were measured using a conductivity detector. The publication includes details on "analytical methods," "analytical parameters," and "instrument configuration." 【Contents】 ■ Column ■ Solution ■ Analytical Method ■ Analytical Parameters ■ Instrument Configuration *For more details, please refer to the PDF document or feel free to contact us.

  • 940-GIF-1.gif
  • Analytical Equipment and Devices
  • Lithium-ion battery
  • Secondary Cells/Batteries

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Basics of Ion Chromatography: Pre-treatment Edition [Technical Document]

IC: Ion Chromatography A clear explanation of sample pretreatment for ion chromatography, including combustion methods.

**Basic Principles of Ion Chromatography: Pre-treatment Edition** Table of Contents Pre-treatment for Ion Analysis 1.1 Purpose of Pre-treatment 1.2 Is Pre-treatment Necessary? 1.3 Influence of Coexisting Components 1.4 Is Pre-treatment for Ion Chromatography Special? Sample Dissolution and Extraction 2 Dissolution 3 Extraction 3.1 Unit Operations Used in Extraction 3.2 Extraction of Ions from Oil Samples by Liquid-Liquid Extraction Method 3.3 Extraction of Ions from Solid Residues by Ultrasonic Extraction Method 3.4 Extraction of Ions from Organic Samples by Organic Solvent Dissolution - Liquid-Liquid Extraction Method 3.5 Extraction of Ions from Food Samples 4 Dissolution by Combustion Method 5 Distillation Total of 20 Pages (Including Cover)

  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Bulk water quality management of seawater in shrimp farms using ion chromatography [Technical Document]

Automating water quality management by simultaneously measuring nitrite, nitrate, and phosphate in seawater from shrimp farms using ion chromatography.

The concentrations of nitrite, nitrate, and phosphate in the seawater of the shrimp farm were measured using an ion chromatograph with a conductivity detector and a UV/VIS detector after chemical suppression.

  • 948-6204-2.jpg
  • Analytical Equipment and Devices
  • Ion Chromatography
  • Biofeed for Fisheries

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Ion Chromatography Technical Document: Creating a Wide Range Calibration Curve in a Single Measurement

Introducing a technique for creating a calibration curve for ion chromatography that covers a wide concentration range in a single measurement.

In ion chromatography with a conductivity detector and suppressor, it is often the case that the calibration curve is not actually linear. Particularly when the calibration curve needs to cover a wide concentration range, applying multiple calibration curves for different concentration ranges can lead to more accurate measurement results. By using MagIC Net software, multiple calibration curves can be created in a single measurement. This means that the optimal calibration curve for all ions is applied, improving the accuracy of the measurement results. This method can be applied to environmental waters such as tap water, seawater, and rainwater.

  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Ion Chromatography Technical Document] Measurement of Five Anions in Human Urine

An application that measures five types of anions contained in human urine using ion chromatography.

Using dialysis technology for automatic sample pretreatment, measurement of chloride, nitrate, phosphate, sulfate, and oxalate in urine using anion exchange chromatography.

  • 940_858_3909_550X550.jpg
  • 930_858_withmale3702_550X550.jpg
  • 4470_550X550.jpg
  • Analytical Equipment and Devices
  • Ion Chromatography
  • Other physical property measurements and component analysis

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Ion Chromatography Technical Document: Measurement of Chloride and Other Anions in Surfactant Solutions

Measurement of fluoride, glycolic acid, monochloroacetic acid, and chloride in surfactant solutions by ion chromatography.

Quantification of fluoride, glycolic acid, monochloroacetic acid, and chloride in surfactant solutions using ion chromatography.

  • 940_858_3909_550X550.jpg
  • 930_858_withmale3702_550X550.jpg
  • 4470_550X550.jpg
  • Analytical Equipment and Devices
  • Ion Chromatography
  • Other cleaning machines

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration