We have compiled a list of manufacturers, distributors, product information, reference prices, and rankings for analysis.
ipros is IPROS GMS IPROS One of the largest technical database sites in Japan that collects information on.

analysis Product List and Ranking from 40 Manufacturers, Suppliers and Companies

Last Updated: Aggregation Period:Sep 03, 2025~Sep 30, 2025
This ranking is based on the number of page views on our site.

analysis Manufacturer, Suppliers and Company Rankings

Last Updated: Aggregation Period:Sep 03, 2025~Sep 30, 2025
This ranking is based on the number of page views on our site.

  1. ビーエルテック Tokyo//Testing, Analysis and Measurement
  2. 一般財団法人材料科学技術振興財団 MST Tokyo//Testing, Analysis and Measurement
  3. 西進商事 Hyogo//Industrial Machinery
  4. 4 同仁グローカル Kumamoto//others
  5. 5 大同分析リサーチ Aichi//Service Industry

analysis Product ranking

Last Updated: Aggregation Period:Sep 03, 2025~Sep 30, 2025
This ranking is based on the number of page views on our site.

  1. Certified single-element and mixed standard solutions for ICP-AES/ICP-MS wet analysis. 西進商事
  2. Continuous Flow Analysis System (CFA) "MiSSion" ビーエルテック
  3. Simple screening test for residual antibiotics in milk: "Charm DIP Test"
  4. 4 Fluorine, Cyanide, and Phenol Measurement Device SWAT ビーエルテック
  5. 5 Equipment Diagnostic Device Online Vibration Meter Mitaro Series MK-64 JFEアドバンテック 計測診断事業部

analysis Product List

526~540 item / All 646 items

Displayed results

Differential Thermal Analysis: Thermogravimetric Analysis (TG-DTA)

Observe the trends of weight loss rate, decomposition, oxidation, combustion, etc., when heat is applied to the sample!

We would like to introduce the "Differential Thermal Analysis: Thermogravimetric Analysis (TG-DTA)" test conducted by our company. This test observes the trends of weight loss rate, decomposition, oxidation, combustion, etc., when heat is applied to the sample. Differential Thermal Analysis (TG-DTA) can be adjusted according to your requirements, including temperature, heating rate, and atmosphere gas. We will discuss the testing conditions separately. 【Test Details】 ■Item Number: K565 ■Required Amount: 10ml ■Main Target Oil Types: Engine oil, automotive gear oil, industrial gear oil, machine oil, crude oil, raw materials, additives, and other sludges and solvents. *For more details, please refer to the related links or feel free to contact us.

  • Testing Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Exam] Ion Analysis (2 Ions)

Add ultrapure water to the sample to extract anions! Measure using ion chromatography.

We would like to introduce our "Ion Analysis (2 Ions)" test. This test quantitatively measures the concentration of various anions (Cl-, NO3-, NO2-, PO43-, SO42-) in the sample. Ultra-pure water is added to the sample to extract the anions, which are then measured using ion chromatography. Please feel free to contact us if you have any requests. 【Test Details】 ■Item Number: K563 ■Required Volume: 100ml ■Main Target Oil Types: FAME (Fatty Acid Methyl Ester), gasoline, kerosene (including jet fuel), diesel (including blended diesel) *For more details, please refer to the related links or feel free to contact us.

  • Testing Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Test] CHN Analysis (Elemental Analyzer)

A test to quantify the carbon, hydrogen, and nitrogen components in the sample! We will determine the elemental concentrations.

We would like to introduce the "CHN Analysis (Elemental Analyzer)" test conducted by our company. This test quantitatively measures the carbon, hydrogen, and nitrogen content in the sample. The carbon, hydrogen, and nitrogen in the sample are converted into carbon dioxide, water, and nitrogen oxides in a high-temperature combustion tube. After reducing the nitrogen oxides to nitrogen, we detect each product and determine the elemental concentrations. 【Test Details】 ■ Item Number: K562 ■ Required Amount: 20ml ■ Standard Number: JPI-5S-65-11 ■ Main Target Oil Types: Heavy oil, engine oil, automotive gear oil, industrial gear oil, machine oil, gasoline, kerosene (including jet fuel), diesel (including mixed diesel) *For more details, please refer to the related links or feel free to contact us.

  • Testing Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Exam] Infrared Spectroscopic Analysis (Analysis)

Analyzing the spectrum obtained from infrared spectroscopy (K526)! Conducting speculation on foreign substance contamination, etc.

We would like to introduce the "Infrared Spectroscopic Analysis" test conducted by our company. By analyzing the spectra obtained from infrared spectroscopic analysis (K526), we perform qualitative analysis of samples, comparisons with new oils, and speculations on foreign substance contamination. If you require more detailed analysis, please feel free to consult with us separately. 【Test Details】 ■Item Number: K5261 ■Main Target Oil Types: Gasoline, Kerosene (including jet fuel), Light Oil (including mixed light oil), Heavy Oil, Residual Oil, FAME (Fatty Acid Methyl Ester), Engine Oil, Crude Oil/Feedstock Oil/Additives, Automotive Gear Oil, and other sludges, solvents, industrial gear oils, machine oils, greases. *For more details, please refer to the related links or feel free to contact us.

  • Testing Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Exam] Infrared Spectroscopic Analysis

Mainly targeting organic compounds! Samples can be measured in either liquid (liquid film method) or solid (ATR method).

We would like to introduce the "Infrared Spectroscopy" test conducted by our company. This test involves irradiating a sample with infrared light and measuring the transmitted (or reflected) IR spectrum. It mainly targets organic compounds, and samples can be measured in either liquid (liquid film method) or solid (ATR method) form. 【Test Details】 ■ Item Number: K526 ■ Required Amount: 5ml ■ Main Target Oil Types: Industrial gear oils, machine oils, greases, gasoline, kerosene (including jet fuel), light oil (including mixed light oil), heavy oil, residual oil, FAME (fatty acid methyl esters), engine oils, crude oil, raw oils, additives, automotive gear oils, and other sludges and solvents. *For more details, please refer to the related links or feel free to contact us.

  • Testing Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Differential Thermal Analysis: Differential Scanning Calorimetry (DSC)

Test to observe changes in thermal energy of the sample! Temperature and cooling rate can be adjusted according to your requirements.

We would like to introduce the "Differential Thermal Analysis: Differential Scanning Calorimetry (DSC)" test conducted by our company. This test observes changes in the thermal energy of the sample. The Differential Thermal Analysis (DSC) can be adjusted according to your requirements, such as temperature and cooling rate. We will discuss the testing conditions separately. Please feel free to contact us when you need our services. 【Test Details】 ■Item Number: K5651 ■Required Amount: 10ml ■Standard Number: - ■Main Target Oil Types: Engine oil, automotive gear oil, industrial gear oil, machine oil, light oil (including mixed light oil), crude oil, raw oil, additives, and other sludges and solvents. *For more details, please refer to the PDF document or feel free to contact us.

  • Contract Analysis

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Exam] Infrared Spectroscopic Analysis (Analysis)

We will conduct qualitative analysis of the sample, comparison with new oil, and speculation about foreign substance contamination!

We would like to introduce the "Infrared Spectroscopic Analysis" test conducted by our company. By analyzing the spectra obtained from infrared spectroscopic analysis (K526), we perform qualitative analysis of samples, comparisons with new oils, and speculations about foreign substance contamination. If you require a more detailed analysis, please feel free to consult us separately. 【Test Details】 ■Item Number: K5261 ■Required Amount: - ■Standard Number: - *For more details, please refer to the PDF document or feel free to contact us.

  • Contract Analysis

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Thin Film Analysis and Evaluation

We will evaluate the types and quantities of constituent elements, membrane quality, etc.! We propose a comprehensive analysis.

We would like to introduce our "Thin Film Analysis and Evaluation" services. Thin films are one of the important factors for enhancing the functionality of electronic devices. We propose comprehensive analysis of thin films. Please feel free to contact us when you need our services. 【Details】 ■ Composition Evaluation ■ Impurity and Contamination Evaluation ■ Bonding State ■ Density Evaluation ■ Evolved Gases ■ Shape Observation *For more details, please download the PDF or feel free to contact us.

  • Other analysis and evaluation services

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Evaluation of buried interfaces using HAXPES with synchrotron radiation.

The detection depth increases, allowing for the evaluation of deeper areas!

We would like to introduce our evaluation of buried interfaces using "Hard X-ray Photoelectron Spectroscopy (HAXPES) with Synchrotron Radiation." X-ray Photoelectron Spectroscopy (XPS) allows for the analysis of surface composition and state, making it an essential technique for surface analysis. While laboratory-type XPS (Al Kα: 1.5 keV) is limited to evaluating extreme surfaces of about 3 nm, using external facilities for Hard X-ray Photoelectron Spectroscopy (HAXPES) at 8 keV enables the evaluation of deeper regions, such as buried interfaces in multilayer structures and stack structures close to actual devices. 【Features】 ■ Greater detection depth compared to conventional XPS ■ Measurement of photoelectrons from deeper energy levels ■ Easier state analysis due to the absence of overlaps with simultaneously generated Auger electrons ■ Utilization of third-generation synchrotron facilities (SPring-8) as a high-brightness X-ray source *For more details, please download the PDF or feel free to contact us.

  • Other analysis and evaluation services

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Solder heat resistance test for surface mount components

Moisture accumulated inside the component vaporizes due to thermal stress! Stress occurs due to volume expansion.

In the "Solder Heat Resistance Test for Surface Mount Components," we simulate the process from moisture-proof packaging of surface mount components to reflow, evaluating their thermal stress resistance. In cases of defects that occur during the test, moisture accumulated inside the components vaporizes due to thermal stress, causing volume expansion and resulting in stress. This stress can lead to delamination and cracks at the interface. Since these anomalies are difficult to detect visually, we use an ultrasonic microscope to inspect the internal adhesion state. [Test Flow] ■ Confirm initial state ■ Dehumidify in a constant temperature chamber ■ Humidify in a constant temperature and humidity chamber ■ Apply thermal stress using a reflow device ■ Confirm post-test state *For more details, please download the PDF or feel free to contact us.

  • Other analysis and evaluation services

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Measurement methods for biofilms

Measure the absorbance of the extracted crystal violet solution at 590 nm! Compare the amount of biofilm.

We would like to introduce the "Measurement Method for Biofilms" conducted by our company. Typically, to detect biofilms, a dye called crystal violet is used. This cationic blue dye compound strongly binds electrostatically to the anions of the biofilm constituents in aqueous solution. In organic solvents, the binding weakens, allowing the crystal violet that was bound to the biofilm to be extracted by the organic solvent. 【Other Methods】 ■ Sensory Testing ■ Gravimetric Method *For more details, please refer to the PDF document or feel free to contact us.

  • バイオフィルム測定方法カタログimg.png
  • Other analysis and evaluation services

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

What can be understood through biofilm analysis

Utilized for various evaluations, such as assessing the inhibitory effect of biofilm formation on reverse osmosis membranes!

We would like to introduce what can be understood through biofilm analysis. It is utilized for evaluating the biofilm formation inhibition effects of panels and components used in various household appliances such as refrigerators, washing machines, and air conditioners, as well as for evaluating the biofilm formation inhibition effects of indwelling catheters. Our company has numerous achievements in evaluating biofilm formation suppression and removal capabilities using various materials and agents, so we can propose analysis systems tailored to your objectives and requests. 【Evaluation Achievements (Partial)】 ■ Evaluation of biofilm formation inhibition effects on materials used in bathtubs and piping ■ Evaluation of biofilm removal effects of cleaning agents ■ Evaluation of the inhibition effects on bacterial growth within biofilms by disinfectants, as well as evaluation of their sterilization effects ■ Evaluation of biofilm formation inhibition effects by surface treatment agents *For more details, please refer to the PDF document or feel free to contact us.

  • Other analysis and evaluation services

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Removal of biofilm using sodium hypochlorite solution.

Used for the removal of biofilm formed in sinks, pipes, and washing machines!

We would like to introduce the removal of biofilms using sodium hypochlorite solution based on the biofilm-related analysis conducted by our company. The effectiveness is quicker at higher concentrations, and at a 5% concentration, biofilms can be removed in just a few minutes. The effectiveness of biofilm removal also varies depending on the type of bacteria and the amount of biofilm present. It is also important to properly control the amount of biofilm formation to evaluate the effectiveness of the cleaning agent. 【Features】 ■ The higher the concentration, the quicker the removal; at a 5% concentration, removal is possible in just a few minutes. ■ The amount of biofilm decreases in a concentration-dependent manner with sodium hypochlorite. *For more details, please refer to the PDF document or feel free to contact us.

  • バイオフィルム除去次亜塩素酸Naカタログ.png
  • Other analysis and evaluation services

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Analysis of Angiotensin-Converting Enzyme (ACE) Inhibitory Activity

We will determine the activity of inhibitors against ACE using 3HB-GGG (peptide) as the ACE substrate with the WST method!

We would like to introduce our "Angiotensin Converting Enzyme (ACE) Inhibition Activity Analysis." Angiotensin Converting Enzyme (ACE) converts angiotensin I into angiotensin II, which has blood pressure-raising effects, while simultaneously breaking down bradykinin, which has blood pressure-lowering effects. This enzyme is involved in the increase of blood pressure within the body. In recent years, ACE inhibition activity measurement has been conducted in processed foods such as agricultural products and fermented foods, as well as in beverages. Depending on the nature and purpose of the samples, we will propose suitable pretreatment methods. [Characteristics of Angiotensin Converting Enzyme] - It converts angiotensin I into angiotensin II, which has blood pressure-raising effects, while simultaneously breaking down bradykinin, which has blood pressure-lowering effects, thus playing a role in the increase of blood pressure within the body. *For more details, please refer to the PDF document or feel free to contact us.

  • Other analysis and evaluation services

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Enzyme activity analysis <Amylase activity>

Enzymes that hydrolyze glycosidic bonds of carbohydrates such as starch! Measurement of amylase activity.

We would like to introduce our "Enzyme Activity Analysis <Amylase Activity>". A common method for measuring amylase activity involves adding the extracted enzyme solution to a starch solution and conducting the enzyme reaction at a precise temperature and time. After that, the reaction mixture is mixed with iodine solution over time to measure the blue absorbance. The decrease in absorbance is used to determine the amylase activity. [Analysis Examples] ■ Grains ■ Processed Foods ■ Functional Foods *For more details, please refer to the PDF document or feel free to contact us.

  • アミラーゼ活性カタログ.png
  • Ingredient analysis

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration