271~315 item / All 568 items
Displayed results
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationContact this company
Contact Us Online271~315 item / All 568 items
The "InfinityLab Poroshell 120 Column" enhances analytical efficiency and reliability, significantly improving the performance of various instruments. Whether you desire superior HPLC performance, want to achieve UHPLC performance at lower pressures, or are seeking the highest level of UHPLC performance, this column is suitable for you. Available in three particle sizes: 1.9μm, 2.7μm, and 4μm, allowing you to choose the appropriate particle size based on your separation needs. 【Features】 ■ A column with innovative chiral stationary phase on porous surface particles ■ High-speed, high-separation column that increases throughput and separation capability ■ Excellent inter-batch reproducibility that consistently delivers reliable separation results ■ Selectable particle sizes Particle sizes of 1.9μm, 2.7μm, and 4μm maximize the performance of methods and instruments *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe "Packed GC Column" is designed and manufactured to achieve excellent performance with high reproducibility for various types of samples related to packed column separation, primarily in the analysis of petrochemicals and the chemical industry. By utilizing excellent packing technology with high efficiency and robustness, it ensures inter-column reproducibility and top-class separation efficiency. The UltiMetal treated stainless steel tube reduces peak tailing, improves peak shape, and enhances data accuracy. 【Features】 - High-efficiency packing technology ensures excellent reproducibility in pressure drop, flow characteristics, and separation, eliminating the need for system readjustment after column installation. - A wide range of tube materials (stainless steel, UltiMetal, nickel, glass, copper, PTFE, etc.) - Suitable options can be selected from numerous stationary phases, packing materials, and supports. *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe "LTM Column Module" features a mechanism where heaters and temperature sensors are directly wrapped around a fused silica capillary column. Thanks to Agilent's unique design, the column is heated and cooled extremely efficiently. This significantly shortens the analysis cycle time compared to GC oven technology while also reducing power consumption. Additionally, it can accommodate 7890/6890 GC injectors and detectors with minimal changes to existing methods. **Features** - Compatible with most Agilent J&W capillary GC columns (up to 30m in length) - High-speed temperature programming capable of up to 1800°C/min - Reduced cooling time – achieving less than 1 minute in some configurations - Superior retention time reproducibility and separation compared to conventional GC - Four column modules can be simultaneously controlled with different temperature programs *For more details, please refer to the PDF document or feel free to contact us.*
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe "Duraguard Column" incorporates deactivated fused silica, which helps avoid issues arising from connections. It is a "one-piece" guard column that does not require a press-fit connector. It minimizes contamination at the column inlet, extending its lifespan. Additionally, samples containing difficult-to-separate analytes such as pesticides or drugs can be separated without the influence of unions. 【Features】 ■ One-piece guard column ■ Minimizes contamination at the column inlet, extending column lifespan ■ Concentrates the sample at the column tip for improved peak shape ■ Minimizes contamination from the mass-selective detector (MSD) originating from the column (when used in transfer line) *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe "Ultimate Plus Stainless Steel Capillary Tube" is suitable for many applications due to its high inertness and robustness. It can analyze trace concentrations of active ingredients. We offer three products: transfer line (outer diameter 1/16 inch), guard column, and 50m capillary tube. Please feel free to consult us when you need assistance. 【Features】 ■ Capable of analyzing trace concentrations of active ingredients ■ Extremely durable stainless steel tube with high robustness ■ Three products available: transfer line (outer diameter 1/16 inch), guard column, and 50m capillary tube *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe "Ultimate Plus Inactivated Fused Silica Tube" can improve the performance of the GC flow path when used as a guard column, retention gap, transfer line, or restrictor. It is designed to enhance the inactivity of trace active compounds and is suitable for analyzing samples in environments with high matrix concentrations, such as food safety and forensic laboratories. Additionally, when used as a guard column, it can extend the lifespan of the analytical column. 【Features】 ■ Designed to enhance the inactivity of trace active compounds ■ Usable as a guard column, retention gap, restrictor, or transfer line ■ Can extend the lifespan of the analytical column when used as a guard column ■ Batch tested ■ Can be used as a replacement for Siltek, RXI, and Z-guard inactivated tubes *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe "inert tube" can be used as a guard column or transfer line. It can also be used for transfer lines where inertness is not critical, as well as for other applications. Additionally, the "retention gap" is used to improve peak shapes for specific types of samples, columns, and GC conditions, and can be used with various polarities. 【Features】 ■ Inert Tube - Can be used as a guard column or transfer line ■ Non-inert Tube and Fused Silica - Generally used in capillary electrophoresis ■ Retention Gap - Can improve peak shapes for specific applications *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration"CP-PoraPLOT Amines" is a PLOT column uniquely developed for the analysis of highly volatile amines. It efficiently analyzes under conditions above room temperature and has high selectivity for volatile amines and ammonia. Please feel free to consult us when needed. 【Features】 ■ Guarantees the analysis of volatile amines ■ Efficient analysis under conditions above room temperature ■ High selectivity for volatile amines and ammonia *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe 'CP-Molsieve 5Å' coated with molecular sieve is a GC column suitable for the separation of permanent gases. The analysis time is reduced by 25% compared to packed columns. At room temperature, argon and oxygen can be baseline separated. Additionally, using a thin film type allows for the rapid and symmetrical elution of carbon monoxide. 【Features】 ■ Separation of argon and oxygen under room temperature conditions ■ High separation capability for increased productivity ■ High-precision analysis with symmetrical peaks *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe "HP-PLOT Molesieve Column" separates O2, N2, CO, and CH4 within 5 minutes. Agilent offers two types of molecular sieve PLOT columns with inner diameters of 0.53 mm and 0.32 mm. They can be used in various applications, including atmospheric monitoring. Additionally, it minimizes damage to baseline spikes and multi-port valves. 【Features】 ■ PLOT column for permanent gas analysis ■ Separates O2, N2, CO, and CH4 within 5 minutes ■ Minimizes damage to baseline spikes and multi-port valves ■ Alternative to GS-Molesieve ■ This product, which completely adsorbs water, can be regenerated at 200°C in less than 7 hours *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe product features various advantages of fully porous particle columns, such as high retention, load capacity, and solvent resistance. It can be expanded to suit your method, from UHPLC to preparative LC. Additionally, the InfinityLab Poroshell bonded phase is compatible with the traditional ZORBAX bonded phase, allowing for easy method changes from fully porous particle columns to superficially porous particle columns. 【How to choose the appropriate particle for your method (partial)】 ■1.8μm ZORBAX RRHD: Achieves the highest level of performance with UHPLC equipment - Maximum pressure: 1200 bar - Compatible systems: 1290 Infinity II LC or 1260 Infinity II Prime LC ■1.8 ZORBAX RRHT: Ultra-fast chromatography with a maximum of 600 bar - Maximum pressure: 600 bar - Compatible systems: 1260 Infinity II LC *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe 'ZORBAX RRHD Column' we handle achieves true high-resolution analysis without compromising stability. Thanks to its excellent flexibility, it is possible to increase the flow rate to the column's limit without reducing separation efficiency or quality. With more than 12 types of bonded phases available, including HILIC, you can select the appropriate column according to your analytical needs. 【Features】 ■ Stability up to 1200 bar: Stable use with UHPLC equipment is possible. ■ Separation capability: Stable high-resolution analysis and scalability are achieved with 1.8 μm particles, making method conversion with 3.5 μm and 5 μm particles easy. ■ More reliable compound identification: High-resolution chromatograms and a column with an inner diameter of 2.1 mm enhance MS separation capability. ■ A wide range of selectable bonded phases: By combining ZORBAX and Poroshell 120 families, it becomes easier to accommodate various samples and facilitate method conversion. *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe "ZORBAX Columns / Poroshell Columns" are specially designed products for HPLC analysis with high productivity. The silica used is of extremely high purity, very robust, and highly uniform, providing the highest level of reliability. Additionally, one of the features is the extremely wide range of phases and column configurations that cater to diverse application needs. 【Features of ZORBAX Columns】 ■ Excellent options and flexibility for low molecular weight and reversed-phase biomolecule analysis with over 18 phases, including Eclipse Plus and HILIC ■ Easy method development that demonstrates excellent performance across a wide range of target compounds and conditions ■ Improvement of UHPLC methods ■ Outstanding peak shape performance due to proven innovative silica and bonding technology ■ Long-term reliability by having the necessary options available when needed for analysis and preparative purification *For more details, please refer to the PDF materials or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThis product is a UHPLC column that achieves a maximum operating pressure of 120 MPa. When combined with the Agilent 1290 Infinity LC System, it delivers the highest level of performance. It is suitable for continuous analysis with durability and stable reproducibility, making it compatible with high-pressure UHPLC systems from various manufacturers. 【Features】 ■ Achieves a maximum operating pressure of 120 MPa through optimization of hardware and packing processes ■ Delivers the highest level of performance when combined with the Agilent 1290 Infinity LC System ■ Equivalent selectivity to existing ZORBAX columns ■ Durability and stable reproducibility suitable for continuous analysis ■ Compatible with high-pressure UHPLC systems from various manufacturers *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe "CarboPLOT P7" is a column compliant with ASTM D 2505. It is suitable for the analysis of samples containing oxygen or air. It can separate nitrogen and carbon monoxide, demonstrating excellent performance for quantifying carbon monoxide at the ppm level. 【Features】 ■ Column compliant with ASTM D 2505 ■ Stability and robustness that enhance result reproducibility ■ Fast separation of carbon monoxide and carbon dioxide ■ Separation of oxygen and nitrogen ■ Analysis of carbon monoxide at the ppm level *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe "GS-CarbonPLOT" is a column with high stability and a bonded carbon layer stationary phase. The temperature limit has been extended to 360°C. It has retention stability that is not affected by water. Agilent's commitment to reliability and reproducibility in its products supports the improvement of quality levels demanded by chromatography experts. Please feel free to consult us when needed. 【Features】 ■ High stability, bonded carbon layer stationary phase ■ Unique selectivity for inorganic and organic gases ■ Temperature limit extended to 360°C ■ Suitable for GC/MS - does not generate particles ■ Retention stability that is not affected by water *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration"CarboBOND" is a column compliant with ASTM D 2505. It is suitable for the analysis of hydrocarbons in ethylene, gases in ethylene and propylene, He, Xe, CO, Ne, CH4, CO2, O2/Ar, N2, and Kr. High-boiling compounds can also be eluted in a short time, and since it is not affected by water, the reproducibility of retention times is excellent. 【Features】 ■ Column compliant with ASTM D 2505 ■ Maximum operating temperature extended to 300°C ■ Stability and robustness enhance the reproducibility of results ■ Chemical bond type, no particle trap required *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration"CP-SilicaPLOT" is a column that provides high separation and fast analysis. It is ideal for the analysis of COS, CFC, hydrocarbons, propylene, and sulfur gases in ethylene. It can analyze carbon dioxide and sulfur gases at the ppm level and separate cyclopropane and propylene. Please feel free to contact us when you need assistance. 【Features】 ■ Retention time is unaffected by water ■ Analyzes carbon dioxide and sulfur gases at ppm levels ■ Separates cyclopropane and propylene *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe "GS-GasPro" is a column that can be used at temperature limits of -80 to 260/300°C. With its unique bonded silica PLOT column technology, it offers retention stability that is not affected by water. Agilent's commitment to reliability and reproducibility in its products supports the improvement of quality levels demanded by chromatography experts. Please feel free to consult us when needed. 【Features】 ■ Unique bonded silica PLOT column technology ■ Suitable for analysis of light hydrocarbons and sulfur gases ■ Retention stability unaffected by water ■ Separates CO and CO2 with a single column ■ Ideal PLOT column for GC/MS - does not generate particles *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe "HP-PLOT Al2O3 M" is a column that can separate gases at room temperature. It is suitable for accurate quantitative analysis of dienes, particularly for separating propadiene and butadiene from the flow of ethylene and propylene. It has undergone different inertization treatments on Al2O3, providing good resolution in hydrocarbon isomer analysis. 【Features】 ■ Inertized with KCl ■ Low polarity alumina phase ■ Suitable for KCl inertized alumina ■ Recommended for many ASTM methods ■ Standard column suitable for low hydrocarbon analysis of C1 to C8 hydrocarbon isomers *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration"GS-Alumina" is a general-purpose column suitable for the analysis of light hydrocarbons in C1 to C8 hydrocarbon isomers. It is fast, efficient, and highly sensitive. Due to its regenerability, it is recommended as an alternative to sodium sulfide alumina. It is also suitable for the separation of propylene from cyclopropane. Please feel free to consult us when needed. 【Features】 ■ High polarity alumina phase ■ Special inertization ■ Fast, efficient, and highly sensitive ■ Separation of C1 to C4 saturated and unsaturated hydrocarbons ■ General-purpose column suitable for the analysis of light hydrocarbons in C1 to C8 hydrocarbon isomers *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe "HP-PLOT Al2O3 S" is a column that can separate gases at room temperature. It is suitable for KCI-treated inactive alumina. Different inert treatments have been applied to Al2O3, providing good resolution in hydrocarbon isomer analysis. We offer products with film thicknesses of 5.00, 8.00, and 15.00 μm. Please feel free to consult us when you need assistance. 【Features】 ■ Inactivated with KCl ■ Lower retention for olefins compared to corresponding paraffins ■ A standard column suitable for the analysis of lower hydrocarbons in C1 to C8 hydrocarbon isomers ■ Particularly suitable for accurate quantitative analysis of dienes, especially separating propyne and butadiene from the flow of ethylene and propylene *For more details, please refer to the PDF materials or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe "CP-Al2O3/Na2SO4" is a column for the analysis of C1 to C5 hydrocarbons and impurities. It can analyze more compounds at once than packed columns, offering high separation capability and allowing for analysis in a shorter time. Compared to capillary columns using liquid phases, this product has high selectivity and can separate C1 to C5 hydrocarbon isomers. 【Features】 ■ High separation capability for hydrocarbons ■ Short analysis time for hydrocarbons at temperatures above room temperature ■ Expands analysis range with two polarities ■ Metal column resistant to physical shocks *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe "CP-Al2O3/KCl" is a column for the analysis of C1 to C5 hydrocarbons and impurities. It can analyze more compounds at once than packed columns, offers high separation capability, and allows for analysis in a shorter time. Compared to capillary columns using a liquid phase, it has higher selectivity and can separate C1 to C5 hydrocarbon isomers. 【Features】 ■ High separation capability for hydrocarbons ■ Short analysis time for hydrocarbons at temperatures above room temperature ■ Expands the range of analysis with two polarities *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration"GS-Alumina KCl" is a column that has undergone special inertization and can be rapidly regenerated. This product, which completely adsorbs water, can be regenerated at 200°C in less than 7 hours. It is also suitable for the separation of cyclopropane from propylene and is recommended as an alternative to sodium sulfide alumina due to its regenerability. 【Features】 ■ High polarity alumina phase ■ Special inertization ■ Faster, more efficient, and highly sensitive compared to equivalent packed columns ■ Minimal conditioning required ■ Recommended as an alternative to sodium sulfide alumina due to its regenerability *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe "HP-PLOT Al2O3 KCl" is a column that can separate gases at room temperature. It is suitable for the analysis of low molecular weight hydrocarbon isomers from C1 to C8. It has been treated with different inertization methods on Al2O3, providing good resolution in hydrocarbon isomer analysis. Please feel free to consult us when you need assistance. 【Features】 ■ Low polarity alumina phase ■ Inertized with KCl ■ Recommended for many ASTM methods ■ Suitable for alumina treated with KCl inertization ■ Lower retention of olefins compared to corresponding paraffins *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration"PoraPLOT S" is a column for the analysis of hydrocarbons and ketones. It uses divinylbenzene-vinylpyridine as an adsorbent. It is suitable for the analysis of moderately polar volatile compounds that require higher temperatures than the maximum usage temperature. Please feel free to consult us when you need assistance. 【Features】 ■ Elution of volatile compounds from high polarity to non-polar with symmetrical peaks ■ Minimization of particle shedding ■ Good reproducibility *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration"PoraPLOT U" is an analytical column for halogenated compounds, hydrocarbons, and ketones. It elutes high-polarity volatile compounds with well-symmetrical peaks. Water in the sample does not affect the retention time and does not cause broadening. Please feel free to consult us when needed. 【Features】 ■ Elutes volatile compounds from high polarity to non-polar with symmetrical peaks ■ Minimizes particle shedding *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration"HP-PLOT U" is a column with a stationary phase bonded with divinylbenzene/dimethacrylate ethylene glycol. It can be used in a wide range of applications including C1 to C7 hydrocarbons, CO2, methane, air/CO, water, dimethacrylate glycol-containing oxygen compounds, amines, solvents, alcohols, ketones, and aldehydes. Due to its high polarity, it has different selectivity and shows good peak shapes, especially for water-containing substances. 【Features】 ■ Bonded divinylbenzene/dimethacrylate ethylene glycol ■ Higher polarity than HP-PLOT Q ■ Suitable for C1 to C7 hydrocarbons, CO2, methane, air/CO, water, oxygen-containing compounds, amines, solvents, alcohols, ketones, and aldehydes ■ Provides high separation in a shorter time compared to traditional packed columns *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe "GS-Q" is a column suitable for the analysis of gases containing fluorinated compounds and sulfur compounds. (Excluding SO2) It can be used within a temperature range of -60 to 250°C. The minimum conditioning time required is 1 hour, and it separates ethane, ethylene, and acetylene. Please feel free to contact us when you need assistance. 【Features】 ■ Porous divinylbenzene homopolymer ■ A PLOT column with intermediate polarity between Porapak-Q and Porapak-N ■ Separates ethane, ethylene, and acetylene ■ Not suitable for quantifying polar compounds ■ Minimum conditioning time: 1 hour *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration"HP-PLOT Q" is a column made of bonded polystyrene-divinylbenzene. It can be used at a temperature limit of -60 to 270/290°C. Good separations are achieved in applications involving hydrocarbons, CO2, methane, air/CO, water, polar solvents, sulfur compounds, and more. It provides high separation in a shorter time compared to traditional packed columns. Please feel free to consult us when you need assistance. 【Features】 ■ Bonded polystyrene-divinylbenzene (DVB) column ■ A PLOT column with intermediate polarity between Porapak-Q and Porapak-N ■ A PLOT column that serves as an alternative to packed columns ■ High separation in a shorter time than traditional packed columns ■ Requires a minimum of 1 hour for conditioning *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration"PoraPLOT Q-HT" is a column for the analysis of volatile compounds. The maximum operating temperature has been expanded to 290°C. It can be used for applications involving halogenated compounds, hydrocarbons C1 to C6, organic solvents, and more. Please feel free to consult us when you need assistance. 【Features】 ■ Suitable for the analysis of a wide range of volatile compounds from high polarity to non-polar ■ Water elutes with sharp peaks, improving quantification accuracy ■ Stable reproducibility of retention times *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration"PoraPLOT Q" is a column suitable for the analysis of a wide range of volatile compounds. This product can elute water with a sharp peak. It is capable of analyzing not only high-polarity volatile compounds but also non-polar hydrocarbons and permanent gases. Please feel free to consult us when you need assistance. 【Features】 ■ Applicable for the analysis of a wide range of volatile compounds from high polarity to non-polar ■ Elutes water with a sharp peak, improving quantification accuracy ■ Stable reproducibility of retention times *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration"PoraBOND U" is a chemical bond-type PLOT column that uses a high-polarity polymer as an adsorbent. The maximum operating temperature has been expanded from 190°C to 300°C. By keeping the bleed level low, the detection limit can be lowered, and the stabilization time of the column can also be shortened. Additionally, because it is a chemical bond-type column, it can be applied to analytical methods that require pressure changes. 【Features】 ■ Expanded maximum operating temperature ■ Low bleed type improves data accuracy and detection limits ■ Chemical bond type for long lifespan *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration"PoraBOND Q" is a GC capillary column that can be widely used for the analysis of volatile organic solvents and hydrocarbons. This product is capable of withstanding repeated analyses of moisture-containing samples. The polymer used as the adsorbent has high purity, and even when used at 320°C, decomposition of compounds due to the adsorbent is minimal. 【Features】 ■ Provides stable data with a chemically bonded PLOT column ■ Capable of analyzing various hydrocarbons ■ Expanded maximum operating temperature *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe "Particle Trap Integrated PLOT PT Column" is designed to enhance laboratory analysis work. There is no need to install a separate particle trap, allowing for leak-free analysis to be performed easily and reliably. The integrated particle trap technology is incorporated into the column as a single continuous fused silica tube. 【Features】 ■ Enables analysis using GCMS and Capillary Flow Technology (CFT), which have been difficult with PLOT columns until now. ■ No unions or traps are required for connecting a separate particle trap. ■ The integrated particle trap technology is incorporated into the column as a single continuous fused silica tube. *For more details, please refer to the PDF materials or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThis is an introduction to the target GC columns in accordance with the 18th revision of the Japanese Pharmacopoeia (Ministry of Health, Labour and Welfare Notification No. 220, June 7, 2021). It includes items such as "nitrous oxide" and "acethexamide" under "Pharmaceutical Articles," as well as "part numbers" and "specified columns." You can view detailed information through the related links. We encourage you to read it. 【Listed Items (Partial)】 ■ Pharmaceutical Articles ■ Test Items ■ Part Numbers ■ Names *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationAgilent Technologies, Inc. offers GC columns with smart keys. The smart key allows for monitoring of the column profile and the usage status of the GC column. Additionally, a wide range of stationary phases is available, from ultra-nonpolar and polyethylene glycol (PEG) to stationary phases tailored for specific applications. 【Features】 ■ The smart key enables automatic detection of instrument configuration and monitoring of usage status during operation, supporting the automation of method development. ■ A wide selection of stationary phases (low polarity, medium polarity, high polarity, application-specific stationary phases) is available. ■ Strict quality control specifications and testing ensure long-term column-to-column performance and accurate separations. ■ Optimization of the GC flow path with Agilent Ultra Inert liners, low bleed septa, certified vials, and gas screen filters. ■ Designed for the Agilent 8890 GC system. *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe "CP-FFAP CB" is a column that guarantees the analysis of free fatty acids. Due to its high maximum operating temperature of 250°C, it can analyze free fatty acids from C2 to C24 in a single measurement without the need for derivatization. By using a chemically bonded liquid phase, it prevents the breakdown of the liquid phase due to acids. Even with continuous injection of large amounts of water or organic solvents, the column does not get damaged. 【Features】 ■ Guarantees the analysis of free fatty acids ■ Analyzes fatty acids from C2 to C24 in one go without the need for derivatization ■ High durability against water and organic solvents ■ Chemically bonded for long lifespan *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration"CP-Sil 88" is a column that uses stabilized high-purity cyano-propyl as the liquid phase. It demonstrates high separation capability even for compounds with similar boiling points and polarities, such as positional isomers and geometric isomers. Please feel free to contact us when you need assistance. 【Features】 ■ High selectivity for positional isomers and geometric isomers ■ High-purity cyano-propyl liquid phase ■ Non-covalent high-polarity column *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationWe would like to introduce the column "HP-88" that we handle. It is designed for the separation of fatty acid methyl esters (FAME) and is highly polar. It excels in the separation of cis/trans isomers compared to "DB-23" and is designed to withstand even higher temperatures while having nearly the same selectivity as "CP-Sil 88." 【Features】 ■ (88%-cyanopropyl) methylallyl polysiloxane ■ Upper limit temperature 250/260℃ ■ High polarity ■ Designed for the separation of cis/trans fatty acid methyl esters (FAMEs) ■ Even better separation of cis-trans isomers than "DB-23" *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration"DB-FastFAME" is a cyano-propyl phase designed for the high-speed and selective separation of both saturated and unsaturated fatty acid methyl esters (FAME). It also accommodates the separation of challenging cis-trans FAME isomers without compromising the separation capability obtained with conventional 100m columns. In less than 8 minutes, it can separate conventional FAMEs, including C18:1 and C18:2 cis/trans isomers, as well as common FAMEs such as DPA and EPA found in dairy fat, vegetable oils, and fish oils. 【Features】 ■ A cyano-propyl phase (G48) designed for the high-speed and selective separation of FAME ■ Ensures reproducibility of FAME equivalent chain length (ECL) values through individual testing with FAME mixtures ■ Complies with the requirements of AOAC, AOCS, and IOC regulatory methods ■ Chemically bonded, cross-linked type, solvent-washable ■ Intuvo specifications are also available *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration"Select Volatiles" is an application column that resolves the peak shape of 1,4-dioxane and the separation of 1,4-dioxane-d8 and 1,2-dichloropropene. Due to its inner diameter of 0.20 mm, it is effective in reducing analysis time and saving helium gas. Additionally, it excels in reproducibility and durability for purge and trap-GC/MSD and headspace-GC/MSD analyses. 【Features】 ■ The peak shape of 1,4-dioxane is very good. ■ 1,4-dioxane-d8 and 1,2-dichloropropane are baseline separated. ■ The inner diameter of 0.20 mm is effective in reducing analysis time and saving helium gas. ■ Excellent reproducibility and durability in purge and trap-GC/MSD and headspace-GC/MSD analyses. *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe "Select Low Ammonia" column is designed to enable simple and rapid analysis of ammonia gas in light hydrocarbons using GC/NCD. This column achieves a low detection limit for ammonia at the ppbv level. Please feel free to contact us when needed. 【Features】 ■ Low detection limit for ammonia in light hydrocarbons ■ Designed for GC/NCD ■ Restrictor connected ■ It has undergone testing based on the industry's very stringent QC specifications for column bleed, sensitivity, and efficiency, allowing for highly reliable qualitative and quantitative results. *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe "Select Mineral Oil" column is designed for the high-speed analysis of mineral oils and features a stabilized non-polar bonded phase. It can withstand temperatures up to 375/400°C and enables high-speed analysis based on the DIN H53 and DIN-EN-ISO 9377-2 methods. With excellent temperature stability, it can analyze hydrocarbons from C4 to C40 in less than 10 minutes, significantly reducing bake-out time. 【Features】 ■ Stabilized non-polar bonded phase designed for the high-speed analysis of mineral oils ■ Appropriate selectivity that enhances the reliability of analysis results for total petroleum hydrocarbons (TPH) based on the DIN H53 N-ISO 9377-2 method ■ Capable of analyzing hydrocarbons from C4 to C40 in less than 10 minutes ■ Low bleed ■ Available in fused silica and UltiMetal *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration