316~360 item / All 568 items
Displayed results
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationContact this company
Contact Us Online316~360 item / All 568 items
The column "DB-TPH" handled by our company is designed for the analysis of total petroleum hydrocarbons (TPH), soil analysis, and the analysis of leaks (LUFT) from underground fuel tanks. It can perform three analyses (gasoline range organic compounds, diesel range organic compounds, motor oil) in a single injection. It allows for solvent cleaning and is compatible with a temperature range of -10 to 320°C. Additionally, high quality is ensured through extensive QC testing, demonstrating excellent performance in petroleum analysis applications. 【Features】 ■ Designed for the analysis of total petroleum hydrocarbons (TPH), soil analysis, and LUFT analysis ■ Capable of performing three analyses (gasoline range organic compounds, diesel range organic compounds, motor oil) in a single injection ■ High-speed analysis ■ Chemical bonding and cross-linking type ■ Solvent cleaning is possible *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationOur column "CP-Select CB for MTBE" ensures highly reproducible results in the analysis of MTBE in reformulated gasoline. It features a wide dynamic range suitable for the quantification of MTBE, maximizing productivity for increasingly demanding volatile compound applications. It is ideal as a primary analysis column or as a complementary confirmation column. 【Features】 ■ Designed for the analysis of MTBE in reformulated gasoline ■ Unique selectivity for MTBE ■ Wide dynamic range suitable for the quantification of MTBE ■ Suitable as a primary column or confirmation column ■ Subjected to testing based on the industry's very stringent QC specifications for column bleed, sensitivity, and efficiency, allowing for highly reliable qualitative/quantitative results *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe "DB-MTBE" we handle is a column with a low-polarity stationary phase. It is of the chemical bonding and crosslinking type, allowing for cleaning with solvents. This product undergoes extensive testing based on extremely strict industry QC standards and is precisely designed to enable purge and trap injection without low-temperature concentration. It can separate MTBE from 2-methylpentane and 3-methylpentane, demonstrating excellent resolution over a temperature range of 35 to 260/280°C. 【Features】 ■ Low-polarity stationary phase ■ Separates MTBE from 2-methylpentane and 3-methylpentane, improving the reliability of quantitative results ■ Purge and trap injection possible without low-temperature concentration ■ Chemical bonding and crosslinking type ■ Cleaning with solvents is possible *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe DB-502.2 is a column that achieves excellent peak shape in analyses based on EPA Method 502.2. It features a chemical bond and crosslinking type, and can be cleaned with solvents. Rigorous testing based on extremely strict industry QC standards ensures that highly accurate and consistent analytical results can be obtained. Additionally, a wide operating temperature range of 0 to 260/280°C is one of the characteristics of this precisely designed product. 【Features】 - A 105m column is also available for the analysis of volatile compounds - Excellent peak shape - Chemical bond and crosslinking type - Can be cleaned with solvents - Due to testing based on the industry's very stringent QC specifications regarding column bleed, sensitivity, and efficiency, highly reliable qualitative and quantitative results can be achieved. *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe "HP-VOC" is a column precisely designed to exhibit excellent performance in the analysis of volatile organic compounds. The effective temperature range is -60 to 280/290°C, optimized for EPA Methods 502.2, 524.2, and 8260. This chemical bond/cross-linked type column provides high-quality peak shapes and can be used for applications requiring the analysis of purgeable or volatile organic compounds, volatile aromatic hydrocarbons, and unsaturated hydrocarbons. 【Features】 ■ Optimized selectivity for U.S. EPA Methods 502.2, 524.2, and 8260 ■ Low polarity ■ Excellent peak shape ■ Chemical bond/cross-linked type ■ Washable with solvent ■ Subjected to testing based on very stringent industry QC specifications for column bleed, sensitivity, and efficiency, allowing for highly reliable qualitative/quantitative results. *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe "DB-VRX" is a low-polarity column designed with unique selectivity to achieve appropriate resolution for volatile compounds. It features excellent peak shape and fully complies with U.S. EPA Methods 502.2, 524.2, and 8260. This type of column, which utilizes chemical bonding and cross-linking, does not require cooling below room temperature to separate six "gases." A wide operating temperature range of -20 to 260°C is also one of its characteristics. 【Features】 ■ Unique selectivity designed to achieve appropriate separation capability in the analysis of volatile compounds: U.S. EPA Methods 502.2, 524.2, and 8260 ■ The 0.45mm inner diameter column has a greater theoretical plate count per meter than the 0.53mm inner diameter column, minimizing co-elution in GC methods ■ No cooling below room temperature is required for the separation of six "gases" ■ Fast analysis - Less than 30 minutes (with appropriate sample throughput) - Less than 8 minutes (when using a 0.18mm inner diameter column) *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe "CP-Select 624 Hexane" is a column designed for the separation of hexane isomers and dichloromethane, offering excellent reproducibility. Specialized QC tests for applications ensure appropriate resolution and inter-column reproducibility. Please feel free to contact us when you need assistance. 【Features】 ■ A stationary phase equivalent to USP G43 optimized for the separation of hexane isomers and dichloromethane ■ Separates acetonitrile and dichloromethane with a specified resolution of ≧1.0 according to USP <467> Residual Solvents ■ Excellent inter-column reproducibility ■ Undergoes testing based on very stringent industry QC specifications for column bleed, sensitivity, and efficiency, allowing for highly reliable qualitative/quantitative results ■ Ensures the resolution of the CP-Select 624 Hexane column for separating dichloromethane from hexane isomers through application-specific QC tests *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe "CP-Select 624 CB" is a column that further enhances the reproducibility of the proven 624 stationary phase. Bleed is kept to 1/2 to 1/3 of that of typical columns (for a column with a length of 30m, an inner diameter of 0.53mm, and a film thickness of 3.00μm, the bleed specification is 9pA). With 6% cyanopropylphenyl and 94% dimethylpolysiloxane as the stationary phase, maximum inter-column reproducibility is ensured through rigorous synthesis based on strict standards and thorough characterization. 【Features】 ■ Reliable and precise separation of EPA-designated volatile compounds according to EPA methods 524.2, 624, and 8015. ■ Designated column for the pharmacopoeial method V.3.3.9 for residual solvent analysis, ensuring compliance. ■ Excellent inter-column reproducibility. ■ Low bleed. *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe DB-624 is a GC column specifically developed for the analysis of volatile contaminants. It is suitable for U.S. EPA Methods 501.3, 502.2, 503.1, 524.2, 601, 602, 8010, 8015, 8020, 8240, and 8260. Our company continues to pursue further improvements in analytical performance standards such as separation efficiency, retention time reproducibility, and peak height ratios. 【Features】 ■ Specifically developed for the analysis of volatile contaminants ■ No cryo-focus required for U.S. EPA Method 502.2 ■ Suitable for U.S. EPA Methods 501.3, 502.2, 503.1, 524.2, 601, 602, 8010, 8015, 8020, 8240, and 8260 ■ Excellent inertness towards active substances ■ Chemical bonding and cross-linking type *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe "DB-EUPAH" column is optimized to achieve maximum performance in the analysis of all 16 types of polycyclic aromatic hydrocarbons (PAHs) regulated by the EU. Testing with application-specific QC test mixtures is conducted on all columns. It has very high thermal stability, allowing for accurate analysis of high-boiling PAHs such as dibenzopyrene. 【Features】 ■ Designed for the analysis of EU-regulated PAHs ■ Testing with application-specific QC test mixtures is conducted on all columns ■ Excellent resolution for important isomers such as benzo(b,j,k)fluoranthene ■ Very high thermal stability, allowing for accurate analysis of high-boiling PAHs such as dibenzopyrene ■ Excellent S/N ratio *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration"Select PAH" is a capillary column that serves as a single solution for the analysis of polycyclic aromatic hydrocarbons (PAH). With excellent resolution for PAH isomers, it allows for the rapid, easy, and accurate quantification of PAHs in environmental and food samples. Since all isomers are separated in a single run, reliable analysis results without false positives can be obtained. 【Features】 ■ Completely separates all PAH isomers, providing accurate analysis results without false positives ■ Fully separates EPA-designated PAHs, including chrysene, triphenylene, and benzo(a)fluoranthene, in under 7 minutes, and EU-regulated PAHs in under 30 minutes ■ Provides rapid results in a single analysis ■ High sensitivity due to low bleed *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration"CP-Sil 88 for Dioxins" is an ultra-high polarity column specifically designed for the separation of dioxins and dibenzofurans. It features an integrated retention gap, which prevents issues caused by solvent condensation and allows for repeated splitless injection without degrading the stationary phase. Additionally, the column's lifespan is extended, and data quality is significantly improved. 【Features】 ■ High-polarity stationary phase with selectivity specialized for the separation of dioxins and dibenzofurans ■ Integrated retention gap with no leaks, extending column lifespan during splitless injection ■ Capable of measuring low concentrations of 2,3,7,8-TCDD ■ Columns with a thin film configuration and a temperature program limit of 270°C are also available *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration"DB-Dioxin" is a column designed for the analysis of polychlorinated dibenzo-p-dioxins (PCDD) and polychlorinated dibenzofurans (PCDF). It is capable of separating 2,3,7,8-TCDD and 2,3,7,8-TCDF from all other isomers in a single analysis. A 100 psi regulator is required to achieve the appropriate carrier gas flow rate. 【Features】 ■ Designed for the analysis of polychlorinated dibenzo-p-dioxins (PCDD) and polychlorinated dibenzofurans (PCDF) ■ Capable of separating 2,3,7,8-TCDD and 2,3,7,8-TCDF from all other isomers in a single analysis ■ Low bleed ■ Chemical bonding and cross-linking type ■ Washable with solvent *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe "CP-Sil 5/C18 CB for PCB" is a column with a C18 substituent that has lower polarity than 100% polydimethylsiloxane. Due to the absence of a cyano group, it allows for ECD detection with a high S/N ratio. With a 100m column, it can separate important isomer pairs 28/31, 56/60, 149/118, 105/153/132, and 170/190. 【Features】 ■ Designed for high-resolution analysis of PCBs ■ Has a C18 substituent and lower polarity than 100% polydimethylsiloxane ■ Allows for ECD detection with a high S/N ratio ■ Offers suitable column lengths for the separation of important isomer pairs 28/31, 56/60, 149/118, 105/153/132, and 170/190 *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe "HP-5ms Semi-Volatile" is a column that has been confirmed through testing to be inert to highly active compounds such as acidic and basic compounds. It demonstrates industry-leading sensitivity and consistency within an effective temperature range of -60 to 325/350°C. Testing is conducted based on Agilent's strict QC industry standards, and it features a chemical bond and cross-linking type, allowing for cleaning with solvents. 【Features】 ■ Has the same selectivity as HP-5 (5%-phenyl)-methylpolysiloxane ■ Non-polar ■ Ultra-low bleed suitable for GC/MS ■ Inertness to active compounds such as acidic and basic compounds confirmed through testing ■ Improved sensitivity and mass spectrum integrity due to excellent S/N ratio *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe "DB-5.625" is a non-polar column of the chemical bonding type, enhanced in inertness and sensitivity through special processing. It is suitable as a standard column for the analysis of semi-volatile compounds using EPA methods 625, 1625, 8270, and CLP protocols. It features excellent thermal stability, a high temperature limit, and low bleed. Special testing has ensured performance that exceeds EPA performance standards for semi-volatile compounds. 【Features】 ■ Performance comparable to (5%-phenyl)-methylpolysiloxane ■ Non-polar ■ Performance exceeding EPA performance standards for semi-volatile compounds ■ Inert to basic, neutral, and acidic compounds ■ Excellent thermal stability, allowing for a high temperature limit and low bleed *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe "CP-Sil 8 CB for PCB" is a column that excels in high-temperature stability and is capable of continuous splitless injection. Due to the absence of cyano groups, it allows for ECD detection with a high S/N ratio. It is suitable for the ECD detection of trace amounts of PCBs and offers excellent high-temperature stability, resulting in low bleed and ultra-long life. 【Features】 ■ Excellent high-temperature stability, capable of continuous splitless injection ■ Designed for the analysis of PCBs based on the DIN method 51527 ■ Suitable for the ECD detection of trace PCBs ■ Excellent high-temperature stability leads to low bleed and ultra-long life ■ Subjected to testing based on the industry's very strict QC specifications for column bleed, sensitivity, and efficiency, ensuring highly reliable qualitative/quantitative results *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe "CP-Sil PAH CB UltiMetal" is a column that combines a stationary phase with excellent thermal stability and an UltiMetal stainless steel column tube. Thanks to its unique column configuration that leverages the advantages of both components, it is capable of separating all 16 types of PAHs designated by the EPA in accordance with EPA Method 610. It can also be used for fingerprint analysis and pattern recognition of complex hydrocarbon mixtures. 【Features】 ■ Separates all 16 types of PAHs according to EPA Method 610 ■ Low bleed stationary phase with excellent thermal stability ■ Extremely robust UltiMetal stainless steel capillary column ■ Supports temperatures up to 400/425°C ■ Has undergone testing based on the industry's very stringent QC specifications for column bleed, sensitivity, and efficiency, ensuring highly reliable qualitative and quantitative results. *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe "VF-17ms for PAH" is a column that can separate polycyclic aromatic hydrocarbons, which are regulated by the EU and EPA, in less than 30 minutes. With inertization technology, it improves data quality and maximizes the reliability of analytical results, making it suitable as a confirmation column for EPA methods. It is a chemical bond/crosslink type that can be cleaned with solvents, helping to reduce column replacement costs. 【Features】 ■ Capable of separating polycyclic aromatic hydrocarbons regulated by the EU and EPA in less than 30 minutes ■ Improves data quality through inertization technology ■ Highly suitable as a confirmation column for EPA methods, maximizing the reliability of analytical results ■ A chemical bond/crosslink type that can be cleaned with solvents, helping to reduce column replacement costs ■ Subjected to tests based on very strict QC specifications in the industry regarding column bleed, sensitivity, and efficiency, allowing for highly reliable qualitative/quantitative results *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration"Rapid-MS" is a capillary column that performs GC/MS analysis at speeds approximately 3 to 5 times faster under temperature ramp conditions and about 10 times faster under isothermal conditions. To accommodate a wide range of analyses, it is available with film thicknesses from 0.1 to 1.0 μm, while also improving the S/N ratio by about 3 times. It can be connected to any manufacturer's GC. 【Features】 ■ Maximizes productivity with rapid analysis ■ Excellent sensitivity following the FactorFour VF-5ms ■ Compatible with any manufacturer's GC (used for GC/MS) *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe "HP-PAS5" is a non-polar column specifically designed and treated for the analysis of organochlorine pesticides. The operating temperature range is -60 to 325/350°C, and it has undergone ECD testing to minimize pesticide decomposition and achieve low ECD bleed. It features chemical bonding and cross-linking, is washable with solvents, and has been tested against strict QC industry standards, providing high reliability in the accuracy and integrity of analytical results. 【Features】 ■ Non-polar ■ Specifically designed and treated for the analysis of organochlorine pesticides ■ ECD testing ensures minimal pesticide decomposition and low ECD bleed ■ Chemical bonding and cross-linking type ■ Washable with solvents *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe "DB-CLP1/CLP2" is a highly flexible universal column pair for nine types of EPA dual ECD pesticide methods. The medium-polarity stable phase enables reliable analysis with high speed and low bleed. The reliable high-speed column provides excellent separation capability along with outstandingly low bleed, eliminating the need for time-consuming column exchanges. 【Features】 ■ Universal column pair designed for pesticide analysis ■ Suitable for dual column, dual ECD GC analysis ■ Medium-polarity stable phase enables reliable analysis with high speed and low bleed ■ Eliminates the need for time-consuming column exchanges ■ Tested with strict testing procedures, with performance summary sheets attached to all columns *For more details, please refer to the PDF materials or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe DB-608 is a column that demonstrates excellent performance in the efficient analysis of chlorine-based pesticides and PCBs. This product, widely used in accordance with U.S. EPA Methods 608, 508, and 8080, achieves excellent inertness and recovery rates without decomposing pesticides. It features a chemical bond and cross-linking type, and is washable with solvents. 【Features】 ■ Specifically designed for the analysis of chlorine-based pesticides and PCBs ■ U.S. EPA Methods: 608, 508, 8080 ■ Excellent inertness and recovery rates without decomposing pesticides ■ Washable with solvents ■ Successor to the HP-608 *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe "CP-Sil 19 CB for Pesticides" is a column designed for the analysis of pesticides. With lower bleed than standard polymers, it not only improves the S/N ratio and minimum detectable quantity but also has a higher temperature limit, allowing for shorter analysis times. This product comes with a connection-type retention gap for on-column injection, enabling very good detection limits. 【Features】 ■ Suitable as a confirmation column for reliable results ■ Medium polarity ■ Useful as a confirmation column ■ Chemically bonded and cross-linked type, allowing for solvent washing ■ This column includes a connection-type retention gap for on-column injection, providing very good detection limits *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe "CP-Sil 8 CB for Pesticides" is a column that achieves linear column response at the femtogram level. This product is equipped with an integrated retention gap, which prevents issues caused by solvent aggregation, allowing for repeated splitless injections without degrading the phase. Furthermore, the integrated retention gap prevents leaks from connections, significantly extending the column's lifespan. 【Features】 ■ Improved productivity due to linear column response down to the femtogram level ■ Proven excellent inertness through tests using DDT, providing reliable data ■ On-column injection is possible ■ The integrated retention gap prevents issues caused by solvent aggregation, allowing for repeated splitless injections without degrading the phase *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe "VF-1701 Pesticides" is a column specifically designed for the analysis of trace pesticide residues. Our columns undergo pre-shipment testing with key pesticides, including endrin and aldrin, ensuring appropriate performance and consistency of results. Additionally, they are highly deactivated for the analysis of trace pesticides, allowing for better detection limits. 【Features】 ■ Designed specifically for the analysis of trace pesticide residues ■ Individual column tests conducted using key pesticides, including endrin and aldrin ■ Enhanced detection limits for measuring trace pesticides due to advanced deactivation ■ Proven performance with ECD or MS detection ■ Improved sensitivity achieved through ultra-low bleed *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe "DB-1701P" is a low/mid-polarity GC column. It has been tested to minimize pesticide degradation and ensure low ECD bleed. It can be used as a substitute for HP-PAS1701. It features chemical bonding and cross-linking, and is capable of solvent cleaning. 【Features】 ■ Low/mid polarity ■ Substitute for HP-PAS1701 ■ Specifically designed and treated for the analysis of organic chlorine pesticides ■ Tested to minimize pesticide degradation and ensure low ECD bleed ■ Solvent cleaning available *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe "VF-5 Pesticides" column is specifically designed for the analysis of pesticide residues at trace concentrations. Our columns undergo pre-shipment testing with key pesticides, including endrin and aldrin, ensuring appropriate performance and consistency of results. Due to rigorous testing based on the industry's very strict QC specifications regarding column bleed, sensitivity, and efficiency, reliable qualitative and quantitative results can be obtained. 【Features】 ■ Designed specifically for the analysis of pesticide residues at trace concentrations ■ Advanced passivation to enhance ECD and MS detection ■ Achieves appropriate performance and consistency of results through testing with key pesticides, including endrin and aldrin ■ Low bleed *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration"CP-Wax for Amines" is a column designed for the analysis of C4 to C10 amines, diamines, and aromatic amines. It complies with EPA Method 607 and features symmetrical peaks due to the inactivation of basic reagents. Please feel free to contact us if you have any inquiries. 【Features】 ■ For the analysis of C4 to C10 amines, diamines, and aromatic amines ■ Complies with EPA 607 ■ Symmetrical peaks due to the inactivation of basic reagents *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationWe would like to introduce our product, "CP-Wax for Volatile Amines and Diamines." It is optimized for the analysis of volatile amines and diamines, particularly C3 to C8 amines and diamines, providing symmetrical peaks due to the inert performance of basic reagents. It demonstrates good inertness towards basic compounds. Please feel free to contact us when you need assistance. 【Features】 ■ Reliable analysis of volatile amines and diamines ■ Symmetrical peaks due to the inactivation of basic reagents ■ Good inertness towards basic compounds *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationWe would like to introduce our product, 'CP-Sil 8 CB for Amines.' It has thermal stability up to 350°C and can be used for the analysis of various amines, particularly C3 to C20 and alkanolamines. For details on QC test conditions, including test mixtures and chromatograms, please refer to the Agilent J&W GC Column Performance Summary that comes with each GC column. 【Features】 ■ Base-inactive treated 5% phenyl polysiloxane ■ Optimized inertness for a variety of amine compounds ■ Thermal stability up to 350°C ■ Capable of separating amines and alkanolamines up to C20 ■ Base-inactive treated columns are also available as CP-Wax for Amines *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration"CP-Volamine" is a column optimized for the separation of volatile amines. Coated with a non-polar stationary phase, it generates symmetrical peaks through MPD (Multi-Purpose Deactivation) technology. It is highly stable and can analyze volatile amines even when the sample contains a high percentage of water. 【Features】 ■ Non-polar stationary phase ■ Excellent stability for samples containing water ■ Improved productivity with a maximum temperature of 265°C ■ Provides sharp amine peaks with accurate results due to high inertness ■ Exhibits excellent performance even when the sample contains water *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThis product is a column that enables the analysis of silanes at ppm levels through a stabilized trifluoropropyl-methyl polysiloxane phase. The film thickness is very thick, achieving a large capacity and high retention capability for volatile silanes. Due to low bleed, composition analysis and impurity analysis can be performed down to ppm levels, and the low surface activity improves peak shape. Typical applications include % level or trace impurity analysis targeting alkylated chlorosilanes. 【Features】 ■ Large capacity and high retention capability ■ Low bleed ■ Excellent peak shape achieved by reducing surface activity ■ High sample holding capacity and retention capability provided by thick film thickness ■ Usable with valves, direct, split/splitless injection ports *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration"Select BioDiesel" addresses the important challenge of extending the lifespan of columns used at very high temperatures of up to 400°C. While conventional fused silica can be used, in many cases, high temperatures shorten the lifespan of the column. By using UltiMetal columns along with a highly stable stationary phase, the consistency of results is improved, and column damage is virtually eliminated. [Features] ■ High precision and durability achieved through UltiMetal technology ■ Reliable analytical results ensured through pre-testing ■ Excellent column lifespan during operation at up to 400°C ■ UltiMetal columns with superior stability in stationary phase ■ Convenient pre-connected retention gap that has undergone leak testing *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationBiofuels are gaining attention as fuels that complement or serve as alternatives to petroleum-based fuels. This product is designed for biodiesel analysis, optimized for specific applications, and complies with ASTM and CEN testing standards. It demonstrates excellent performance in the analysis of free glycerin, total glycerin, FAME, and trace methanol. 【Features】 ■ Complies with EN14105, ASTM D6584, EN14103, EN14110, EN14331 methods ■ Chemical bond and crosslinking type ■ Capable of obtaining highly reliable qualitative/quantitative results ■ Specially treated for a temperature limit of 400°C ■ Fused silica tubes coated with polyimide for high-temperature use *For more details, please refer to the PDF materials or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration"Select Al2O3 MAPD" is an alumina PLOT column suitable for the analysis of reactive hydrocarbons. It is stable up to 200°C and can analyze hydrocarbons up to C10. The adsorption of reactive (polar) hydrocarbons and the unstable response are significantly improved. It has up to twice the response for MAPD, making it particularly important for impurity analysis. 【Features】 ■ Suitable for the analysis of reactive hydrocarbons ■ Optimized to enhance sensitivity and response ■ Improved operational efficiency through faster analysis ■ Particularly important for impurity analysis, with twice the response for MAPD ■ Capable of obtaining highly reliable qualitative/quantitative results *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe "Select Permanent Gases/CO2" is a column that connects CP-Molsieve 5Å for permanent gas analysis and CP-PoraBOND Q for carbon dioxide analysis in parallel. It allows for the selection of column size according to the analysis purpose, such as rapid analysis, low concentration analysis, and quantification of argon and oxygen. It performs the analysis of permanent gases and carbon dioxide in a single run. 【Features】 ■ Reduces analysis costs with isothermal separation above 40℃ ■ Maximum operating temperature is 300℃ ■ Although it is a parallel column, there is one injector and one detector *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationWe would like to introduce 'CP-Squalane' handled by Agilent Technologies. It separates C4 to C10 hydrocarbons very effectively based on reliable identification using retention index. It provides a low-polarity liquid phase. Please feel free to contact us when you need assistance. 【Features】 ■ Very effective separation of C4 to C10 hydrocarbons ■ Reliable identification based on retention index ■ Low-polarity liquid phase *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe "CP-Sil 5 CB for Sulfur" is a column optimized for the analysis of volatile sulfur compounds. It achieves high productivity in trace analysis of sulfur compounds up to C7 mercaptans. With a non-polar phase, it can accurately separate based on volatility. High inertness allows for the elution of sulfur dioxide, resulting in high-quality data and low detection limits. 【Features】 ■ Optimized for the analysis of volatile sulfur compounds ■ Achieves high productivity in trace analysis of volatile sulfur compounds up to C7 mercaptans ■ Provides accurate analytical results based on volatility due to the non-polar phase ■ Achieves high-quality data and low detection limits through the elution of SO2 due to high inertness ■ Capable of obtaining highly reliable qualitative/quantitative results *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration"Select Low Sulfur" is a column designed to meet the specific needs of the petrochemical field, capable of detecting sulfur compounds in propylene at low detection limits. Due to its very high inertness to volatile reactive sulfur components, it achieves extremely low detection limits. Its unique selectivity prevents co-elution and matrix interference in propylene analysis. 【Features】 ■ The column has very high inertness, achieving good peak shapes for active compounds. ■ Low detection limits for sulfur compounds. ■ Prevents co-elution and matrix interference in propylene analysis. ■ High retention of volatile components achieved through a highly permeable PLOT stationary phase. ■ Consistent column inertness achieved through a unique QC testing procedure. *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe "DB-Sulfur SCD" is a column optimized for chemical luminescence sulfur detectors, featuring low bleed and minimal contamination of the SCD ceramic tube. It achieves excellent peak shapes in all GC SCD methods using dimethylpolysiloxane (PDMS) stationary phases, such as ASTM D 5623 and 5504 analyses. It enhances detector stability and reduces maintenance and associated downtime. 【Features】 ■ Improved data reliability ■ Significantly reduced bleed ■ Suitable SCD stability ■ Reduced lab downtime, maintenance, and operational costs ■ Available in various custom configurations *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationWe would like to introduce our product, 'CP-TCEP for Alcohols in Gasoline.' It can elute aliphatic compounds smaller than n-dodecane before benzene, thus avoiding the confusion between aliphatic and aromatic fractions. Furthermore, the excellent separation capability of this column allows for the necessary separation performance required for complex mixtures like gasoline. 【Features】 ■ Designed for alcohol analysis in gasoline ■ Accurately separates alcohols with excellent peak shape ■ Achieves high productivity with temperature stability up to 135°C ■ Separates benzene after n-dodecane due to unique selectivity ■ Provides highly reliable qualitative and quantitative results *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe "CP-SimDist UltiMetal Column" enhances analytical performance up to C120 thanks to its robust inert UltiMetal tube. Since the inner diameter is the same as that of a fused silica (megabore) column at 0.53mm, automatic and smooth on-column injection is possible. The surface has undergone a special inert treatment, resulting in superior reproducibility of retention times compared to other high-temperature columns. 【Features】 ■ Designed to comply with ASTM D2887 and its related test methods ■ Low bleed ■ Supports analysis up to C120 at a maximum temperature of 450℃ ■ Excellent durability with UltiMetal tube ■ 0.53mm inner diameter, same as fused silica *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe "CP-SimDist" is a column specialized for pseudo-distillation (SIMDIS) analysis up to C100. It features low bleed, with a bleed level of 4-5 pA at 400°C. The stable liquid phase at high temperatures and polyimide coating contribute to the longevity of the column. For details on QC test conditions, including test mixtures and resulting chromatograms, please refer to the "Agilent J&W GC Column Performance Summary" included with each GC column. 【Features】 ■ Supports pseudo-distillation analysis up to C100 ■ High-temperature non-polar stationary phase ■ Excellent quantification due to low bleed ■ Long lifespan achieved with high-temperature polyimide coating ■ Capable of obtaining highly reliable qualitative/quantitative results *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe features of the "DB-HT SimDis Column" include consistent high performance suitable for high-temperature simulated distillation (SIMDIS) with a "boiling point" phase and a highly durable stainless steel tube. This product has low bleed and a distillation range of C6 to C110 at an operating temperature range of -60 to 430°C. It also allows for solvent cleaning with chemical bonding and cross-linking types. Since it is tested based on the industry's very strict QC standards, you can always obtain highly accurate results. 【Features】 ■ 100% Dimethylpolysiloxane ■ Highly durable stainless steel tube ■ Maximum temperature: 430°C ■ Distillation range: C6 to C110+ ■ Achieves low bleed even at 430°C *For more details, please refer to the PDF materials or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration