We would like to introduce a case study of our product implementation. When using large floor-standing equipment, there can be concerns such as condensation due to the distance from tabletop testing machines or analytical instruments. We received inquiries about the desire to place testing machines and analytical instruments on the same tabletop for convenience, and we resolved this issue by implementing our equipment. Please feel free to contact us when you need assistance. *For more details, please download the PDF or feel free to reach out to us.*
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration
We will introduce a case of the introduction of a precision dew point gas generation device. To obtain reliable experiments and data on moisture movement within proton-conducting membrane cells and the impact of water vapor, the introduction of our products, which guarantee accuracy and stability, was considered. A mirror-cooled dew point meter was installed, and since a full inspection is conducted during shipping inspections, accuracy and stability guarantees have been realized. Additionally, calibration is regularly conducted through a JCSS-accredited calibration provider. *For more details, please download the PDF or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration
The "me-40DP-2PHW" is a precision dew point gas generator capable of handling precise water vapor across a wide range from low to high humidity. It corresponds to a test space temperature range from room temperature (10 degrees C) to 90 degrees C, with relative humidity ranging from 10% to 95% RH. To generate humidity-adjusted gas below +1.0 degrees Cdp, the pressure in the saturation tank is controlled from atmospheric pressure to 6 atmospheres using a proportional control solenoid valve. It is suitable for development engineers and researchers in various fields who prioritize responsiveness and seek "reliability of absolute humidity values," especially those who have struggled with humidity control or have not succeeded in DIY solutions. 【Features】 ■ Corresponds to a test space temperature range from room temperature (10 degrees C) to 90 degrees C, with relative humidity ranging from 10% to 95% RH ■ Well-suited for precise water vapor handling across a wide range from low to high humidity ■ The pressure in the saturation tank is controlled from atmospheric pressure to 6 atmospheres using a proportional control solenoid valve *For more details, please download the PDF or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration
The "Blank Type" is a basic type of humidity control device that is equipped solely with humidity control functions. It specializes in humidity control, including room temperature dedicated units and high dew point expansion types, and is suitable for use when there is an existing mass flow controller on the upstream side (user side) of the device. It can be controlled externally, making it also suitable for integration into other devices. 【Features】 ■ Basic type with only humidity control functions (supports room temperature dedicated units and high dew point expansion types) ■ Suitable for use when there is an existing mass flow controller on the upstream side (user side) of the device ■ Standard equipped with USB communication port or RS232C communication port ■ Supports complete integration (OEM) *For more details, please download the PDF or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration
The "me-60DP series" is a precision dew point gas generator that supports a volumetric flow rate of up to 10L/min. This product adopts a bubbling method using the two-temperature method, achieving a saturation tank temperature control stability of ±0.03°C. Similar to the me-40DP series, it offers dedicated models for room temperature, high dew point expansion types, and wide range compatible types, allowing data to be exported to a CSV file via communication with a laptop, as well as enabling automatic program operation. 【Features】 ■ Humidified gas dew point accuracy: within ±0.2 to 0.5°C dp at atmospheric pressure ■ Humidified gas dew point stability: within ±0.05 to 0.2°C dp at atmospheric pressure ■ Relative humidity accuracy: within ±0.5 to 2.0% Rh ■ Relative humidity stability: within ±0.3 to 1.0% Rh *For more details, please download the PDF or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration
The "me-80DP series" is a precision dew point gas generator that supports a volumetric flow rate of up to 25L/min. This product includes models specifically designed for room temperature, high dew point expansion, and wide range compatibility. It features a standard USB port for external control (operation software sold separately), allowing communication with a laptop via USB. 【Features】 ■ Designed to support a volumetric flow rate of up to 25L/min ■ Lineup includes room temperature dedicated models, high dew point expansion models, and wide range compatible models ■ External control support via standard USB port ■ CSV output of data and automatic program operation through communication with a laptop *For more details, please download the PDF or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration
The "me-100DP series" is a precision dew point gas generator that supports large volume flow rates and achieves precise humidity control. It accommodates cooling and heating of the saturation tank using a Peltier module and employs a bubbling method based on the two-temperature method. It comes standard with a USB port, allowing for data to be saved as CSV files through communication with a laptop, as well as enabling automatic program operation. 【Features】 ■ Large capacity design supporting flow rates up to 50L/min ■ Cooling and heating of the saturation tank using a Peltier module ■ Humidity control gas generation using a bubbling method based on the two-temperature method ■ Automatic program operation and data saving possible with standard USB port *For more details, please download the PDF or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration
The "me-□□□ADP series" is a precision dew point gas generator that supports large capacities with a humidity gas volume flow rate of 100L/min or more. Heating of the saturation tank is done with a heater, and cooling is performed using a chiller. It supports PC control that allows data to be exported to CSV files via communication with a laptop and USB port, as well as automatic program operation. It achieves precise humidity control with a dew point accuracy of ±0.3 to 0.8°Cdp at atmospheric pressure, a dew point stability of ±0.1 to 0.5°Cdp, a relative humidity accuracy of ±0.5 to 2.0%Rh, and a relative humidity stability of ±0.3 to 1.0%Rh. 【Features】 ■ Supports large capacities with a humidity gas volume flow rate of 100L/min or more ■ Heating of the saturation tank is done with a heater, and cooling is performed using a chiller ■ Supports PC control that allows data to be exported to CSV files via communication with a laptop and USB port, as well as automatic program operation *For more details, please download the PDF or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration
Achieving a humidity control environment with zero condensation! We will introduce a case that improved the reproducibility and reliability of experiments by accommodating chamber temperatures from room temperature to 150 degrees. The tribological properties of materials such as metals can change significantly depending on the humidity environment. High humidity can lead to a thicker layer of adsorbed water on surfaces, which may reduce friction or, conversely, promote wear, making humidity control essential for the reproducibility and reliability of experiments. In this case, we developed a precise dew point generation device using our unique "two-temperature, two-pressure method," simplifying operations. We also undertook the custom development of test chambers tailored to the friction and wear testing machines currently in use, enabling localized friction property evaluations in assessments such as those using atomic force microscopy. [Challenges] ■ The tribological properties of materials such as metals change significantly with humidity. ■ Lack of humidity control leads to insufficient reproducibility and reliability in experiments. *For more details, please download the PDF or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration
We would like to introduce our company's achievements in the production of "Temperature and Humidity Environmental Test Chambers." We have realized performance and evaluation tests that were previously given up on with conventional temperature and humidity control devices. Please take a look at some of our production achievements. We have a track record of manufacturing and delivering capacities ranging from 0.009 liters to 200 liters. 【Production Achievements (Partial)】 ■ Constant Temperature and Humidity Chamber for FT-IR (Test Chamber) ■ Constant Temperature and Humidity Chamber for Microscope (Test Chamber) ■ For Reactors ■ Constant Temperature and Humidity Chamber for Solar Cells (Test Chamber) ■ Constant Temperature and Humidity Chamber for Electronic Circuit Boards (Test Chamber) ■ Constant Temperature and Humidity Chamber for Concrete Samples (Test Chamber) *For more details, please download the PDF or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration
This document introduces a case where a precise humidity generator (recirculating saturation tank method) was implemented for the long-term stability evaluation of solid oxide fuel cells (SOFCs). Traditionally, there were issues such as temperature variations due to external heating, fluctuations in temperature and humidity levels caused by automatic water replenishment, and disturbances from seasonal and room temperature changes, making it difficult to maintain a precise and constant moisture level in hydrogen over extended periods. By introducing this product, the impact of disturbances was minimized, achieving stable humidification. The recirculating saturation tank method, which bubbles the humidified gas back into the water to equilibrate the liquid phase temperature before separating the gas and liquid, dramatically improved the reliability of long-term stability evaluations. [Challenges] - Temperature variations due to external heating and fluctuations in temperature and humidity levels from automatic water replenishment - Impact of disturbances from seasonal and room temperature changes - Maintaining a precise and constant moisture level in hydrogen sent to the fuel electrode over extended periods *For more details, please download the PDF or feel free to contact us.*
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration
We will introduce a case study of the introduction of a large-capacity precision dew point gas generation device. We rented products from other companies and tried various options, but the humidity control devices from other companies could only handle up to 60 degrees Cdp at best, which posed a challenge for producing high-quality products. Therefore, we introduced our humidity control device. This allowed us to meet the stringent requirements for humidity control gas at 90 degrees Cdp at several hundred liters per minute, and we were able to manufacture equipment that generates stable precision dew point gas, making it possible to produce high-quality products and advance our production technology. [Challenges] - The humidity control devices from other companies could only handle up to 60 degrees Cdp, while we needed humidity control gas at 90 degrees Cdp at several hundred liters per minute. - We rented products from other companies and tried various options, but we could not produce high-quality products without our humidity control device. *For more details, please download the PDF or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration
This case introduces the establishment of a humidity control environment requiring a line back pressure of 8 bar and a dew point temperature of 150°C dp. Traditionally, humidity controllers requiring a line back pressure of 8 bar and a dew point temperature of 150°C dp were specifications that other companies had no experience with and would decline due to their difficulty. In this case, we successfully developed and manufactured a device that meets the demanding specifications. By equipping a mirror surface cooling dew point meter and conducting a full inspection of all products during shipping inspection, we have achieved excellent accuracy and stability guarantees. [Challenges] ■ Establishing a humidity control environment requiring a line back pressure of 8 bar and a dew point temperature of 150°C dp ■ Addressing difficult specifications that other companies have no experience with and would decline *For more details, please download the PDF or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration
We would like to introduce a case study of our environmental testing equipment that has been implemented. Conventional equipment was large due to the inclusion of a refrigeration unit and heater. By incorporating a Peltier device, we achieved miniaturization of the equipment and proposed an environment where various micro chambers can be easily connected for testing. [Challenges] ■ Conventional equipment was large due to the inclusion of a refrigeration unit and heater. ■ We want to evaluate characteristics while easily inserting and removing samples on the table. *For more details, please download the PDF or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration
We will introduce a case study of the interlocking system of Micro Equipment Co., Ltd.'s "Precision Dew Point Gas Generation Device." Due to the separation between the researchers' desks and the experimental equipment, researchers faced the inconvenience of having to manually transfer test results from their desks to their computers for each test. There was a need to automate this process. As a solution, we independently developed and implemented an interlocking system between the computer, measuring instruments, and the "Precision Dew Point Gas Generation Device." As a result, we achieved the construction of an embedded system, remote operation, and automation of the testing environment through automatic data acquisition, leading to unmanned operations. [Challenges] ■ The separation between researchers' desks and experimental equipment causes inconvenience for researchers with each test. ■ There is a desire to automate the process of transferring test results from the desk to the computer. *For more details, please download the PDF or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration
We will introduce a case study of the introduction of Micro Equipment Co., Ltd.'s "Precision Dew Point Gas Generation Device." Conventional humidity control devices faced challenges such as non-uniform temperature distribution, condensation occurrence, and the inability to generate accurate saturated vapor pressure. However, by introducing this device equipped with a recirculating saturation tank at its core, we achieved unprecedented stability in water vapor, overcoming these challenges. [Challenges] - Non-uniform temperature distribution, occurrence of condensation, and inability to generate accurate saturated vapor pressure. - While the reliability of absolute humidity values is essential for fuel cell performance evaluation, the amount of water vapor remains unstable. *For more details, please download the PDF or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration
We would like to introduce a case study of our precision humidity control generation device. The conventional split-flow method controls two parameters: flow rate and temperature, making it difficult to strictly control the absolute amount of water vapor generated. Additionally, there are challenges in manufacturing "humidity control devices" that require delicate control for aspects such as "humidity distribution," "condensation prevention," and "producing gas with an accurate dew point." To address this, we introduced our device that employs a unique dual-temperature dual-pressure method. By consolidating the parameters into one, we can achieve precise control over the absolute amount of water vapor generated. This has enabled the production of devices that maintain 95% humidity at 90°C, realizing precise and stable dew point generation and temperature-humidity settings. [Challenges] ■ High difficulty in manufacturing "humidity control devices" that require delicate control for aspects such as "humidity distribution," "condensation prevention," and "producing gas with an accurate dew point." ■ Strict control is difficult with the conventional split-flow method, which relies on two parameters: flow rate and temperature. *For more details, please download the PDF or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration
Since our establishment in 1996, we have focused on the development and refinement of measurement and control technologies related to pressure, flow, and temperature. Through our experience in developing fuel cell evaluation systems and catalyst evaluation systems, we have arrived at precision dew point control technology. Moving forward, we aim to promote the dissemination of these strengths in the field of precision humidity control devices as a key player in driving innovation. 【Business Content】 ■ Precision humidity generation devices ■ Small circulators ■ Small constant temperature chambers ■ Evaluation devices and aging devices related to fuel cells, catalysts, and gas separation membranes ■ Engineering services related to the above *For more details, please refer to the PDF materials or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe "Precision Humidity Generator" is the ideal humidity generator for setting humidity levels. By incorporating a recirculating saturation tank, it can generate very stable saturated water vapor even in the challenging dew point temperature range of 90°C dp or higher. Additionally, since it is controlled by a Peltier element, there is no need for a refrigeration unit, allowing for a compact and lightweight design of the device. 【Features】 ■ Stability By using a recirculating saturation tank, it can generate very stable saturated water vapor even in the dew point temperature range of 90°C or higher, which was previously considered difficult with conventional saturation tanks. ■ Compact and Lightweight Experimental Equipment The temperature of the saturation tank is controlled by a Peltier element, eliminating the need for a refrigeration unit and achieving a compact and lightweight design. Device dimensions: Width 280 × Depth 340 × Height 320 Device weight: 14 kg ■ Wide Range of Dew Point Areas The temperature control range of the saturation tank is from 0°C to 90°C, allowing this device to cover a very wide range of dew point areas with just one unit.