After performing thermal spraying in an unmanned booth, there is a need to determine whether personnel can enter based on the dust concentration. Here, we introduce a case where safety measures were implemented using a dust measurement device, the Air Dust Monitor. <Challenges Before Implementation> 1) The decision to allow entry was left to individual judgment, and there were concerns about health risks since entry was possible even during dust generation. 2) Entering the booth during film formation could lead to uneven thickness due to the incoming air, potentially resulting in quality defects. Therefore, we propose the Air Dust Monitor, which can monitor the dust conditions in the booth!! For more details, please refer to the related link URL.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationWe will introduce a case of implementing an air particle monitor into the control panel of a tunnel boring machine. Dust generated during tunnel excavation can enter the control panel of the boring machine, leading to inverter failures. <Challenges on Site> 1) It is unclear when and from where dust will enter the control panel. 2) If the inverter fails, it incurs costs and delays recovery due to extended lead times. The "air particle monitor" solves these concerns! For more details, please refer to the related link URL.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationIn a case study at a chemical raw material factory for pigments, we monitored the dust concentration in the workspace that became an issue based on the results of the work environment measurement. <Challenges Before Implementation> 1) The dust concentration in the workspace separated by curtains was identified as a problem during the work environment measurement, and countermeasures were required. 2) Since a particle counter requires on-site measurement each time, there are constraints on the measurement frequency, making real-time monitoring difficult. For more details, please refer to the related link URL.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration■Challenges of Thickener Equipment We often hear from customers that they want to monitor the concentrated sludge that accumulates at the bottom of the thickener. However, since the sludge accumulates in the liquid, they are troubled by not knowing how to monitor it or what kind of measuring instruments to use... If the accumulated sludge cannot be measured... ● The quality of the treated water deteriorates, making reuse difficult. ● The rake experiences increased load and wears out. We want to find a way to solve these challenges! The solution to these concerns is the "sounding type level gauge (weight type level gauge)." The sounding level gauge (Sounding M's) suspends a detection weight at the end of a wire, and by moving the weight up and down, it detects the distance to the accumulated sludge. The weight reliably detects the accumulated sludge without being affected by the resistance of the water.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationIn each stage of secondary battery manufacturing, dust collectors are installed to handle powders and recover materials that leak during work. If the dust collector is functioning properly, it can reliably collect materials without significant issues. However, if the filter deteriorates or wears out, a large amount of material can leak through the tears. This results in the inability to recover expensive materials, leading to significant losses. So, what measures can be taken? A dust monitor is installed on the secondary side of the dust collector (the atmospheric discharge side) to quickly detect raw materials leaking from deteriorated or worn filters, minimizing damage.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationWhat are the strengths of domestically produced products?! Matsushima Majatech's products are developed and manufactured in-house consistently within the country.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration<Cost Reduction> Transportation and accommodation expenses for dispatched workers are not required. Costs can be reduced. <Time Reduction> Visitor management for worker entry education and procedures is no longer necessary. <Safe Operations> Remote adjustments eliminate the need for detailed adjustment work on-site, ensuring safety. Target format: MWLM-PR26 series
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationInstrumentation equipment is essential for the control and monitoring of plants. However, the actual field often cannot avoid harsh environments, which can affect lifespan and lead to sudden failures. Our level gauges are no exception. Therefore, we recommend preventive maintenance (regular inspections) to check and prepare the health of the level gauges in advance. The lifespan of a level gauge is influenced by the lifespan of electronic components, typically around 8 to 10 years. However, the actual lifespan can vary, with some lasting over 15 years and others less than 5 years. This seems to be influenced by the following installation environments. 【Influential Installation Environments】 ■ Intense sunlight ■ Salt damage / corrosive gases ■ Severe vibrations / continuous vibrations ■ Strong noise *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationDust is generated at work sites and dust collectors, and when inhaled, it can affect the health of workers and nearby residents. I believe that factories where dust is generated regularly use external organizations for measurement. However, regular dust measurements can make it difficult to quickly notice dust leaks, which may negatively impact the work environment and surrounding areas. Matsushima Majatech offers dust monitors that monitor dust concentration after dust collection and air dust monitors that monitor dust concentration in low air flow environments, both indoors and outdoors. By quantifying dust concentration in various situations and monitoring it 24 hours a day, we contribute to the following: ● Prevention of health damage ● Reduction of maintenance burden ● Cost reduction 【Product Introduction】 - Dust Monitor - Air Dust Monitor - Air Particle Monitor
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe air dust monitor continuously monitors the dust concentration in the environment, providing peace of mind at the work site.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationIssue At a certain manufacturer's factory, due to installation errors and deterioration after the replacement of filter cloths in dust collectors, over 9 tons of raw materials were leaking from all the dust collectors every month without being recovered. This resulted in a loss of approximately 27 million yen per month for the company, and there is also the issue of air pollution. Just thinking about how much sales would be needed to generate such profits is a waste, isn't it? Therefore, the installation of dust monitors to continuously monitor the leakage amount was required.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationWe would like to introduce a case study of the dust monitor 'PFM-M01E' handled by Matsushima Majatech. When considering capital investment for environmental measures, the challenge is how to reduce costs while taking productivity into account. Therefore, we propose this product. By continuously monitoring dust leakage, it not only contributes to environmental measures but also leads to predictive maintenance, resulting in reduced maintenance costs. 【Case Study】 ■Challenges - Visual monitoring → Already exceeding regulatory standards - Monitoring with a manometer → By the time of discovery, it may already exceed regulatory standards - Manual analysis → There may have been leaks during periods without manual analysis - Preventive maintenance → Maintenance and labor costs are burdensome ■Product Introduced - Dust monitor 'PFM-M01E' ■Benefits - Continuous 24-hour monitoring in place of personnel - Detects minute leaks and predicts blowouts - Interpolates periods without manual analysis - Reduces maintenance costs through predictive maintenance *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationIsn't there something like this? ● Concern about whether there is any deviation in instructions after long-term use ● Feeling the need for regular calibration due to ISO standards and internal guidelines Calibration will be conducted based on the condition, in accordance with the shipping inspection acceptance criteria for the dust monitor.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationBecause it is domestically manufactured with no input risks, we can offer: - Short delivery times - Stable supply - Support Please use our dust monitor calibration service to operate your equipment with peace of mind.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThis document addresses the challenge of "balancing production efficiency and environmental measures" and presents the effectiveness of continuous monitoring of dust. In recent years, environmental issues have become increasingly severe, and dust in exhaust emissions from factories is one of them. Companies are likely facing more pressure than ever to respond with manual analysis monitoring and preventive maintenance after dust collection. For companies, improving production efficiency is also an important requirement, and if environmental measures become a significant burden, it would be counterproductive. This document introduces the current challenges and their solutions, as well as the types and features of automatic dust concentration measuring instruments. [Contents (excerpt)] ■ Increasingly severe environmental concerns ■ What measures are being implemented? ■ Current challenges ■ Solutions ■ Types and characteristics of automatic dust concentration measuring instruments, etc. *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe "vibrating level switch" is effective for detecting waste plastics, as it can detect very light powders with a specific gravity of 0.02g/cm3, unaffected by the dielectric constant. Additionally, the external probe resonates with the internal probe that vibrates slightly, and when the external probe is covered by the measured material, the resonance diminishes, allowing for detection. It can be used not only for level control of waste plastic pellets in coke oven fuel at steel mills but also in cement plants and waste plastic manufacturing equipment. 【Features】 ■ Detection sensitivity is 0.02g/cm3 ■ Easy to adjust without being influenced by electrical characteristics ■ Maintenance is simple due to the absence of moving parts *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationHave you ever experienced malfunctions due to adhesion when detecting levels of highly viscous liquids or moist powders? Matsushima Mejatech's admittance-type level switch 'MAL-110' can avoid troubles caused by adhesion and provide stable level detection. This time, we conducted a demonstration test using a highly conductive slime as the measured substance. Thanks to the guard electrode (with a special structure) canceling the effects of adhesion, there were no malfunctions despite a large amount of adhesive material on the probe. [Test] ■ Demonstration test using slime ■ Test product ・ Admittance-type level switch 'MAL-110' ■ Result ・ No malfunctions *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationLevel measurement is essential in factories and plants, but there are still many challenges in measuring levels in various harsh environments. If these issues remain unresolved, it can lead to inaccurate measurements and equipment damage. Matsushima Majatech, as a manufacturer of level measurement devices, has addressed various measurement challenges, including those related to powders. This document is a collection of case studies featuring the introduction of radar microwave level meters handled by Matsushima Majatech. It includes examples such as the "Wood Chip Chute Introduction Case," which can measure even when there is only wall space available, the "Chicken Manure Silo Introduction Case," which prevents adhesion and reduces cleaning work, and the "Mobile Tripper Introduction Case." Each case highlights key points and is presented with photos and illustrations. [Featured Case Studies (Excerpt)] ■ Wood Chip Chute Introduction Case ■ Chicken Manure Silo Introduction Case ■ Mobile Tripper Introduction Case ■ Mining Plant Introduction Case ■ Beverage Plant Introduction Case *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe radar-type microwave level gauge has excellent tracking capability and is suitable for level control in shafts and detecting blockages in primary crushers. Additionally, since microwaves have the property of penetrating dust and vapor, there is no risk of mistakenly measuring dust or vapor. 【Features】 ■ Improved tracking capability ■ Not affected by dust or vapor ■ Not affected by wind, temperature, or gas *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationWe would like to introduce a case where the radar-type microwave level gauge 'MWLM-PR26H7S' handled by Matsushima Majortech was implemented in a mobile tripper. In the case of laser or ultrasonic types, there was a risk of erroneous measurements due to reflections from dust and steam, and the influence of dust and steam could cause sound waves to attenuate, leading to unstable measurements. By introducing this product, which uses microwaves that have the property of passing through without reflection (noise) from dust and steam, we were able to monitor multiple bunker levels from the mobile tripper. 【Case Study】 ■Challenges - Risk of erroneous measurements due to reflections from dust and steam - Existing level gauges may become unstable due to the influence of dust and steam ■Product Introduced - Radar-type microwave level gauge 'MWLM-PR26H7S' ■Effects - Enabled monitoring of multiple bunker levels from the mobile tripper *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationWe would like to introduce a case study of the radar microwave level gauge 'MWLM-PR26H7S' handled by Matsushima Majortech. There was a problem where there was no installation space above the wood chip chute, making measurement impossible. We fulfilled the request to somehow conduct measurements inside the chute. By installing the level gauge on the side wall and mounting it so that the product faces vertically towards the raw material surface, stable measurements could now be taken from the side. 【Case Study】 ■Challenges - There was no installation space above the wood chip chute, making measurement impossible. ■Product Introduced - Radar microwave level gauge 'MWLM-PR26H7S' ■Effects - Measurements can now be taken from the side.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationWe would like to introduce a case study of the radar-type microwave level gauge 'MWLM-PR26H Series' handled by Matsushima Majatech. In food manufacturing, the mixing of fresh ingredients with old ones can lead to quality accidents. The residual material in the hopper, which causes this issue, cannot be detected by the lower limit switch, so we decided to measure it with a microwave level gauge. 【Case Study】 ■Challenge To prevent contamination, we were visually checking the residual material in the hopper every time we replaced the ingredients. ■Product Introduced Radar-type microwave level gauge 'MWLM-PR26H3S' ■Effect We were able to measure the residual material with the microwave level gauge, eliminating the need for visual confirmation. *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationWe would like to introduce a case where the microwave level meter 'MWLM-PR26H7S' handled by Matsushima Majatech was introduced to a biomass plant chicken manure silo. With the existing level meter, there was constant accumulation of deposits even with a cleaning frequency of once a month. However, after switching to this product, the inside of the antenna after three months showed almost no deposits even without cleaning. By utilizing a PTFE-coated antenna, this product reduces deposits and takes advantage of water droplets from condensation to wash away deposits, thereby reducing cleaning work. [Case Study] ■ Issues - The existing level meter had deposits even with a cleaning frequency of once a month. ■ Introduced Product - Microwave level meter 'MWLM-PR26H7S' ■ Effects - Even without cleaning, water droplets were washing away the deposits.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationWe would like to introduce a case study of the "Radar Microwave Level Gauge" handled by Matsushima Majortech. Temperature measures are necessary for measurements in high-temperature locations such as blast furnaces and incinerators. This product can be used in high-temperature environments by combining it with a "cooling box." Our company designs and manufactures cooling jackets tailored to the site environment, enabling measurements in high-temperature conditions. 【Case Study】 ■Challenge - Temperature measures are necessary for measurements in high-temperature locations. ■Implemented Product - "Level Gauge" + "Cooling Box" ■Effect - Measurements can be taken effortlessly even in high-temperature environments.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationWe would like to introduce a case study of the "Radar Microwave Level Meter" handled by Matsushima Majatech, which has been implemented in sintering equipment (sintering cooler). This product monitors the thickness of the sintered ore layer for process control and checks the levels after feeding and discharging. It avoids heat sources with an L-shaped waveguide antenna and cools the antenna with purging. A heat shield prevents dust from entering the antenna, stabilizing measurement performance. Please use it for controlling input amounts and detecting blockages. 【Case Study】 ■ Installation Site - Sintering Equipment (Sintering Cooler) ■ Installed Product - "Radar Microwave Level Meter"
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationIn accordance with the customer's specifications, which indicated that there was no installation space at the top of the silo, we created a special antenna for the level gauge that bends at a 90° angle and installed it from the side for measurement. For more details, please contact us. Matsushima Mejatech responds to customer requests with customizations made possible by in-house production.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationWe introduce a case study of the radio wave water level gauge handled by Matsushima Majatech, which has been implemented in upstream rivers. This product detects sudden changes in river water levels and alerts to potential flooding. It can respond to extreme water level changes of about 5 meters in approximately 2 seconds. Microwaves have the property of penetrating steam, allowing for stable detection of the water surface even during fog, storms, or heavy rain. Since it measures the water surface non-contact, it can operate without collision or damage even when sediment or driftwood flows by. 【Case Study】 ■ Implementation Location ・River ■ Implemented Product ・Radio Wave Water Level Gauge
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationWe would like to introduce a case study of the radar-type microwave level gauge handled by Matsushima Majatech. There was a problem of false detection due to the influence of bubbles when detecting the liquid level in the container. To address this, we installed a "guide pipe" and introduced our product. Even when bubbles occur at the liquid surface, they do not enter the pipe, allowing for measurement of only the liquid level. 【Case Study】 ■Challenge - False detection occurs due to the influence of bubbles when detecting the liquid level in the container. ■Product Introduced - Radar-type microwave level gauge 'MWLM-PR26H2F' + "Guide Pipe" ■Effect - Even when bubbles occur at the liquid surface, they do not enter the pipe, allowing for measurement of only the liquid level. *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationWe can accommodate corrosive liquids through customization. ● PTFE Antenna By installing a PTFE antenna, measurements can be taken without worrying about corrosive liquids. ● Flat Antenna Even if the antenna cannot be inserted into the tank, measurements can be taken without inserting the antenna into the tank by using a flat antenna. For more details, please contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationWe would like to introduce a case study of the radar-type microwave level gauge handled by Matsushima Majotech. In the chemical tank of a factory's wastewater treatment facility, there was a problem where the level gauge corroded due to the influence of chemicals (such as gases). To address this, we utilized the characteristics of microwaves that can penetrate materials with low dielectric constants, allowing us to implement our product to measure from the outside of the tank. 【Case Study】 ■Challenges - Level gauge corrosion due to chemicals ■Product Introduced - Radar-type microwave level gauge 'MWLM-PR26H**' ■Effects - Measurement can now be conducted from the outside of the tank *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationWe would like to introduce a case where the "Radar Microwave Level Meter" handled by Matsushima Majortech was implemented in a chemical tank. The gas contact part of this product is made of "SUS304." However, if there is still a possibility of corrosion, attaching the optional "PTFE Antenna Cap" to the antenna will prevent corrosive gases from entering and protect the antenna from corrosion. 【Case Study】 ■ Installation Location - Chemical Tank ■ Installed Product - "Radar Microwave Level Meter" + "PTFE Antenna Cap" * Limited to specific models * For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe radar-type microwave level gauge 'MWLM-PR26C1G' handled by Matsushima Majatech features a sensor equipped with a "PTFE antenna cap," and we will introduce a case where it was implemented in an animal fat tank. In some field conditions, condensation and oil droplets may occur. By utilizing the "antenna cap," it prevents the ingress of condensation and oil droplets into the antenna, enabling stable measurements. [Case Study] ■Challenges - Occurrence of condensation and oil droplets ■Product Introduced - Radar-type microwave level gauge 'MWLM-PR26C1G' (PTFE antenna cap) ■Effects - Prevents the ingress of condensation and oil droplets into the antenna, allowing for stable measurements *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationWe would like to introduce a case where the radar-type microwave level gauge 'MWLM-PR26H3F' handled by Matsushima Major Tech Co., Ltd. was implemented in a hot spring water tank. The existing ultrasonic level gauge was experiencing measurement errors due to the influence of steam. After installing our product, the measurement errors were eliminated, which was well received. 【Case Study】 ■Challenge - The existing ultrasonic level gauge was experiencing measurement errors due to the influence of steam. ■Product Implemented - Radar-type microwave level gauge 'MWLM-PR26H3F' ■Effect - Measurement errors were eliminated. *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationSix years since its release, the radar-type microwave level gauge has, thanks to you, been utilized by many customers. However, there have been applications where we were unable to meet customer demands. What is needed to realize that? We will focus on what is necessary now and what can be done now to redesign. In May 2018, the "Microwave Level Gauge" will make its re-debut with an upgraded version while maintaining the same appearance. 【Overview of Version 2.0】 ■ Improved accuracy ■ Enhanced tracking performance ■ Increased resolution ■ Improved noise tolerance ■ Increased power supply tolerance ■ Extended wiring distance *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationWe are customizing our measurements to meet the request of measuring only the sediment in the tank liquid. 1. Adjusting the detection torque to prevent malfunction due to resistance at the water surface. 2. Using a special rope to prevent corrosion from the liquid. 3. Using specially shaped weights to reduce buoyancy and resistance when descending in the liquid. For more details, please contact us. Matsushima Mejatech responds to customer requests with customizations made possible by in-house production.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationI would like to install a sounding level gauge, but there are reasons such as wanting to insert measuring objects and other measuring instruments at the installation location, so there was a request to "have the sounding level gauge stand by in a different location when it is not in use." Therefore, we have developed a "portable sounding level gauge" that can stand by in a different location when not in use. For more details, please contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe "Sunshade Cover" is a product used for "Radar-type Microwave Level Gauges." Even outdoor level gauges can experience temperature increases in the internal unit due to sunlight during the day, which may shorten the product's lifespan. This product helps mitigate the effects of sunlight and contributes to the longevity of the equipment. You can choose from two types: hard and soft. 【Lineup】 ■ Hard Cover - Material: Stainless Steel - Used in locations where robustness is required ■ Soft Cover - Material: PVC - Easy installation type that simply ties with a string *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationWe would like to introduce a case study of the admittance-type level switch 'MAL-110' handled by Matsushima Majatech. In general, capacitive level switches have malfunctioned due to the effects of adhesion. This product cancels the influence of adhesion with guard electrodes, preventing malfunctions. 【Case Study】 ■Challenge - General capacitive level switches malfunction due to the effects of adhesion. ■Product Introduced - Admittance-type level switch 'MAL-110' ■Effect - Reliable detection - The guard electrodes cancel the influence of adhesion, preventing malfunctions. *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationWe would like to introduce a case study of the admittance-type level switch 'MAL-110' handled by Matsushima Majatech. The existing conductive (leak-type) level switch frequently malfunctioned due to adhesion, requiring on-site calls each time. After replacing it with our product, malfunctions due to adhesion ceased, and emergency calls were eliminated. 【Case Study】 ■ Issues - The existing conductive (leak-type) level switch frequently malfunctioned due to adhesion. ■ Introduced Product - Admittance-type level switch 'MAL-110' ■ Effects - Malfunctions due to adhesion were eliminated. *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationWe would like to introduce a case study of the admittance-type level switch 'MAL-110' handled by Matsushima Majatech. There were voices expressing frustration about having to "go to the site every time there was equipment trouble, open the sensor cover, and check the operating status one by one!" In response, we introduced this product equipped with an operating LED on the cover. Now, it is possible to understand the operating status while keeping the cover closed, eliminating the cumbersome task. 【Case Study】 ■ Issue - It is cumbersome to go to the site every time there is equipment trouble, open the sensor cover, and check the operating status. ■ Introduced Product - Admittance-type level switch 'MAL-110' ■ Effect - It has become possible to understand the operating status while keeping the cover closed. *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationWe would like to introduce a case study of the admittance-type level switch 'MAL-110' handled by Matsushima Majatech. Conventional capacitive level switches could only detect oils and fats, leading to overflow when a large amount of foam was generated. By adopting our product, we were able to detect low dielectric constant foam, eliminating the overflow issue. 【Case Study】 ■Challenges - Conventional capacitive level switches could only detect oils and fats, causing overflow when a large amount of foam was generated. ■Product Introduced - Admittance-type level switch 'MAL-110' ■Effects - Successfully detected low dielectric constant foam, eliminating overflow. *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationWe would like to introduce the application examples of the load flow detector 'EFSL-155S' handled by Matsushima Majatech. When there are no items being transported on the conveyor, there may be abnormalities in the upstream process. Additionally, if the normal transport volume is not flowing, it could significantly impact the downstream process. This product is suitable for monitoring the status of the conveyor transport line. Its implementation helps stabilize the production process. [Example] ■ Application: Monitoring the transport status of belt conveyors ■ Introduced product: Load flow detector 'EFSL-155S' *For more details, please refer to the PDF materials or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationWe are currently offering a free "Level Meter/Level Sensor and Dust Concentration Meter Comprehensive Catalog" filled with products such as level meters for powders and liquids, dust monitors, and conveyor protection equipment. The catalog includes information on products like the "Radar Microwave Level Meter," which dramatically improves measurement performance, and the "Triboelectric Dust Monitor," ideal for detecting leaks and tears in bags, enhancing productivity, and addressing environmental and disaster prevention measures. 【Contents】 ■ Radar Microwave Level Meter ■ Sounding Level Meter ■ Dust Monitor ■ Emergency Pull Switch ■ Speed Switch *You can view part of the catalog in PDF format from the download section. If you would like the complete version, please request the materials through the inquiry form.