How to choose a DME-compatible MMG fitting? Three points to check: series, thread, and valve.
When replacing DME Jiffy-tight fittings with MMG in the cooling and temperature control line of molds, both the socket (coupler) and the plug (nipple) should be checked. The key points when selecting replacement parts are as follows:
1. Check the series
Take note of the model numbers of the existing socket and plug, and confirm whether they correspond to DME200 or DME300. For example, a candidate for replacing the DME socket "JS200" is the "JS200J" from the MMG200 series.
2. Match the thread standards and installation dimensions
Check the thread standards and sizes on the mold side, as well as the installation space around the fitting. For types that connect directly to hoses, also verify the hose diameter and connection method.
3. Confirm the presence of valves and usage conditions
Check which component, the socket or the plug, has a valve. Select sealing materials based on the fluid, temperature, and pressure to be used.
The attached document includes examples of corresponding model numbers for DME and MMG. If you would like to verify model numbers, please provide the model numbers of the existing socket and plug along with the usage conditions.