Numerous achievements in public works! Settlement floor correction method 'Teratec Method'
TerraTech method
Teratec method: It's not just about replacement and resurfacing! A floor repair method!
【Numerous achievements with the Ministry of Land, Infrastructure, Transport and Tourism and various local governments】 Quickly and fundamentally resolve issues such as floor tilting, unevenness in public facilities, and voids under roads. Are you still considering just replacement or resurfacing? The Teratec method is chosen for public works as well as warehouses, factories, and stores, with a track record of 4,200 projects! ▼ What is the Teratec method? The "Teratec method" is a patented technique that injects Teratec resin under concrete floors to fill voids caused by sinking, restoring the floor to a level position using the resin's expansion force. "Using the expansion force of Teratec resin, we lift and level sinking or tilted floors." This innovative idea has made it possible to restore floors to a level position quickly without destruction. 【Features of the Teratec method】 - No. 1 market share in Japan* (4,200 construction achievements) - Available for construction 24 hours a day, 365 days a year - Reliable technology with patented and former NETIS registration (QS-080007) * (Market share for sinking correction work using urethane injection method / based on our research) ▶ For more details, please view the catalog from "PDF Download." Feel free to contact us by phone (0120-873-835) or email (info@mainmark.co.jp).
Inquire About This Product
Related Videos
basic information
【Product Specifications】 Standard injection interval: 1.5m Resin compressive strength: 193KN/m² 【What is the Teratech Method?】 This is a patented method that involves injecting Teratech resin under concrete floor slabs (roads) to fill voids beneath the floor with its expanding force, leveling sunken floors. The injection hose can be extended from a 3-ton plant vehicle, allowing for construction in narrow areas without the need to remove any cargo. It is safe for large trucks to pass immediately after the work is completed. 【Addressing Building Tilt and Ground Reinforcement】 Our company employs both civil engineers knowledgeable in ground conditions and architectural engineers familiar with buildings, allowing us to propose and design the optimal method tailored to our customers' needs from various techniques. For more details, please view the catalog from "PDF Download." Feel free to contact us by phone (0120-873-835) or email (info@mainmark.co.jp).
Price information
After investigating the sinking volume and cavity volume, we will provide a design estimate. The inspection is free of charge, so please feel free to consult with us.
Delivery Time
Applications/Examples of results
【Main Clients】 ▼Government Agencies Ministry of Land, Infrastructure, Transport and Tourism Kanto Regional Development Bureau Ministry of Land, Infrastructure, Transport and Tourism Chubu Regional Development Bureau Ministry of Land, Infrastructure, Transport and Tourism Kinki Regional Development Bureau Ministry of Land, Infrastructure, Transport and Tourism Chugoku Regional Development Bureau Ministry of Land, Infrastructure, Transport and Tourism Kyushu Regional Development Bureau Ministry of Land, Infrastructure, Transport and Tourism Hokuriku Regional Development Bureau Ministry of Land, Infrastructure, Transport and Tourism Tokyo Aviation Bureau Tokyo Metropolitan Government, First Construction Office Iwate Prefecture, Department of Land Development Aomori Prefecture, Shimokita Regional Bureau Kyoto Prefecture, Civil Engineering Office Chiba Prefecture, Sewerage Corporation ▼Private Companies Obayashi Corporation Kajima Corporation Taisei Corporation Takenaka Corporation Shimizu Corporation Daiwa House Industry Co., Ltd. Toda Corporation Mitsui Sumitomo Construction Co., Ltd. Ando Corporation Tokyu Construction Co., Ltd. Goyo Construction Co., Ltd. Maeda Corporation Fujita Corporation Nishimatsu Construction Co., Ltd. NIPPO Corporation Please feel free to contact us. Toll-Free Number: 0120-873-835
catalog(3)
Download All CatalogsNews about this product(7)
Company information
The main business activities of Mainmark involve "returning tilted floors and buildings to a level state" and "preventing existing floors and buildings from tilting." We primarily offer the "TerraTech Method," which allows us to level tilted floors without stopping operations, and we provide various construction proposals tailored to our customers' concerns, from investigation to execution. ■ Nationwide responsible construction with over 5,000 completed projects Mainmark has established offices in eight locations across the country and conducts responsible construction nationwide. We serve a wide range of clients, including factories, stores, warehouses, offices, and apartments. ■ Non-disruptive floor tilt and subsidence correction method "TerraTech Method" Our main service, the "TerraTech Method," is a patented technique that injects TerraTech resin (rigid polyurethane foam resin) into concrete floors that have developed tilts, subsidence, steps, or voids due to ground subsidence or earthquakes. The expansion force of the resin levels the sunken floor and fills the voids beneath it. This technology is also registered with the Ministry of Land, Infrastructure, Transport and Tourism's "NETIS," ensuring its reliability. Patent No. 4896949 "Method for Correcting Sunken Floors" NETIS Registration No. "QS-080007"