It can irradiate a small point with a diameter of 13 mm with ultraviolet light.
Features of UVP-30 1) It is compact and can irradiate a point with a diameter of 13mm using ultraviolet light. The UVP-30 is a point-type ultraviolet irradiator that focuses the light from the ultraviolet lamp into a point. 2) You can choose from five wavelengths of near-ultraviolet (UVA): 355nm, 360nm, 365nm, 370nm, and 375nm. You can compare the activation of cellular functions and tanning effects by wavelength. 3) It has a manually adjustable power supply, allowing for easy adjustment of the irradiation amount through current regulation. You can compare the effects of ultraviolet light based on the amount of irradiation. 4) It achieves perfect clean irradiation and can be used in clean rooms or under vacuum conditions. 5) The light-shielding hood ensures the safety of the operator.
Inquire About This Product
basic information
Model UVP-30/f30/355nm/P2m355nm lamp, power cord 2m UVP-30/f15Focusing lens with a focal length of 15mm UVP-30/f30Focusing lens with a focal length of 30mm UVP-30/f40Focusing lens with a focal length of 40mm UVP-30/400nm400nm base-mounted replacement bulb UVP-30/375nm375nm base-mounted replacement bulb UVP-30/370nm370nm base-mounted replacement bulb UVP-30/365nm365nm base-mounted replacement bulb UVP-30/360nm360nm base-mounted replacement bulb UVP-30/355nm355nm base-mounted replacement bulb Hood-30f□Light-shielding hood
Price range
Delivery Time
Applications/Examples of results
Irradiation of ultraviolet curing resin Tire crack testing Photocatalyst testing UV cut glass transmittance testing Accelerated weather resistance test of color-coated steel sheets Comparative test by partial sterilization of culture medium Weather resistance test of resin sheets Weather resistance test of coatings Drying of UV printing Reading of transparent UV ink Ultraviolet weeding effect Ultraviolet surface modification of resin substrates Ultraviolet (UV) cleaning of glass lenses Synthesis of vitamin D by ultraviolet irradiation Ultraviolet fluorescence method for sulfur dioxide Light source for total protein quantification by absorbance photometry Quantification of uranium ore by ultraviolet fluorescence method Light source for thin-layer chromatography
Detailed information
-

Quantification of Uranium Ore by Ultraviolet Fluorescence Method Issues There was a need to quantify a small amount of uranium. ⇒ Improvement Points The molten substance obtained by adding a small amount of uranium to sodium fluoride emits a yellow-green fluorescence under ultraviolet light, and the intensity of the fluorescence is proportional to the content, allowing for semi-quantification by comparing it with known quantities.
-

Light Source for the Spectrophotometric Method of Total Protein Quantification Issues An analytical method was needed that did not use additives to recover samples after measurement. ⇒ Improvement Points The absorbance was measured at a wavelength of 280 nm to quantify proteins. In the case of a crude protein solution containing various proteins, when the absorbance measured using a 1 cm optical path length cell is 1, the protein concentration in that solution is approximately 1 mg/mL. By estimating the absorbance at a protein concentration of 1 mg/mL as 1 and measuring the absorbance at 280 nm, the protein concentration in the sample solution can be estimated. The advantage of this method is that the protein concentration can be calculated simply by measuring the absorbance at 280 nm using a spectrophotometer, making the analytical operation straightforward. Additionally, since no additives are used during the analysis, samples can be recovered after measurement.
-

Ultraviolet Fluorescence Method for Sulfur Dioxide Issues There was a need to measure the concentration of sulfur dioxide emitted into the atmosphere. ⇒ Points for Improvement When UVC is irradiated on the sample, the excited SO2 molecules emit fluorescence as they return to their ground state. The concentration of SO2 in the sample was measured by assessing the intensity of the fluorescence. The advantages of this method are that it is not affected by the flow rate of the sample gas, nor by moisture or carbon dioxide.
-

Synthesis of Vitamin D due to UV radiation Issues Vitamin D deficiency led to poor health. ⇒ Improvement Points By exposing myself to UV-B radiation around 300nm for about 10 minutes a day, Vitamin D was synthesized in the skin, and my health improved.
catalog(1)
Download All CatalogsCompany information
5 reasons that HEATTECH is selected 1. The rich selection of 5 principles and 71 types. Air Blow heater , Near-infrared, Middle-infrared, Far-infrared, and UV heater From the 71 types of products based on the 5 principles of heating system, we will propose the best heater. 2. 9 series 88 types of heater controllers. Manual, Automatic, Speed proportional, Remote control, IOT compliant, Noncontact heating control, One-shot heating, Multistage heating, etc. We propose the optimal heater controller from the multifunctional products. 3. Construction method study materials We have published a number of technical documentation online seminars. 4. Sense of security of verification before introduction. Test piece, test laboratory, in user can verify before introduction. 5. Low-budget one-stop introduction To introduce in testing way, the laboratory kit which gathered something necessary was prepared. : Member of the Kobe Chamber of Commerce and Industry : Member of the Society of Material Science Japan : Member of the Society of Thermophysical Properties Japan : Member of the Japan External Trade Organization Trade Tie-up Promotion Program