List of all products
1891~1935 item / All 595671 items
It won't break even after 1 million repetitions! A mat switch with reliable operation, high durability, and low price. Suitable for options in machine tools as well. Please consult us about delivery t...
- Sensors
We can accommodate high resistance over 10,000 ohms, with diameters ranging from approximately 30 mm to 8 inches, and we also offer thinning and chip processing arrangements!
- Other semiconductors
- Processing Contract
- Wafer
The VSC series oil chillers, which adopt non-Freon refrigerants, are exempt from the Freon Emission Control Law and can achieve high-precision oil temperature management with an accuracy of ±0.1°C.
- Chiller
Easily achieve precise air conditioning just by placing and connecting. The Apiste PAU series of precision air conditioning units allows for flexible temperature control in enclosed spaces.
- Other clean room equipment and facilities
Simply place and connect to easily achieve precise air conditioning. The Apiste PAU series of precision air conditioning units allows for flexible temperature control of enclosed spaces.
- Other clean room equipment and facilities
Simply place and connect to easily achieve precise air conditioning. The Apiste PAU series of precision air conditioning units allows for flexible temperature control in enclosed spaces.
- Other clean room equipment and facilities
Simply place and connect to easily achieve precise air conditioning. The Apiste PAU series of precision air conditioning units allows for flexible temperature control in enclosed spaces.
- Other clean room equipment and facilities
Simply place and connect to easily achieve precise air conditioning. The Apiste PAU series of precision air conditioning units allows for flexible temperature control in enclosed spaces.
- Other clean room equipment and facilities
Simply place and connect to easily achieve precise air conditioning. The Apiste PAU series of precision air conditioning units allows for flexible temperature control in enclosed spaces.
- Other clean room equipment and facilities
Easily achieve precise air conditioning just by placing and connecting. The Apiste PAU series of precision air conditioning units allows for flexible temperature control in enclosed spaces.
- Other clean room equipment and facilities
Simply place and connect to easily achieve precise air conditioning. The Apiste PAU series of precision air conditioning units allows for flexible temperature control in enclosed spaces.
- Other clean room equipment and facilities
Easily achieve precise air conditioning just by placing and connecting. The Apiste PAU series of precision air conditioning units allows for flexible temperature control in enclosed spaces.
- Other clean room equipment and facilities
Simply place and connect to easily achieve precise air conditioning. The Apiste PAU series of precision air conditioning units allows for flexible temperature control in enclosed spaces.
- Other clean room equipment and facilities
Easily achieve precise air conditioning just by placing and connecting. The Apiste PAU series of precision air conditioning units allows for flexible temperature control in enclosed spaces.
- Dust collector
Simply connect it to achieve precise air conditioning easily. The Apiste PAU series of precision air conditioning units allows for flexible temperature control in enclosed spaces.
- Temperature and Humidity Control
Simply place and connect to easily achieve precise air conditioning. The Apiste PAU series of precision air conditioning units allows for flexible temperature control in enclosed spaces.
- Temperature and Humidity Control
Explaining the heat sources of the hydraulic operation system point by point in a manga format! *Manga materials will be provided.
- Chiller
"Manga Material 'Saving Hydraulic Systems! "Oil Chiller Bob"' Now Available" Easy to read in manga format! Explains the causes of hydraulic system failures!
We have released a document titled "Saving Hydraulic Systems! 'Oil Chiller Bob'" that explains hydraulic operation systems in an easy-to-understand manga format. Are there any of you who have introduced a hydraulic operation system but are facing issues such as the oil not cooling or the system going into emergency stop? This document explains the causes of these problems divided into four key points. We also introduce oil chillers for solving these issues, so if you are interested, please download the PDF from the related catalog below or feel free to contact us. [Contents] ■ Heat sources of hydraulic operation systems ■ Filters ■ Fins ■ Sealing properties
When looking at the piping system diagram, cooling equipment appears. This article clearly presents the various types of cooling equipment, including their structures and principles!
- Chiller
Heat is a great enemy for electronic devices! To use them for a long time, it is necessary to keep the temperature low.
- Control Panel Cooler
"Renewal of the Control Panel Heat Exchanger Catalog" Introducing the ENH series heat exchangers for control panels that are useful for heat dissipation and dust prevention!
The ENH series heat exchangers for control panels perform heat exchange due to the temperature difference between the inside and outside of the panel, allowing for heat dissipation from the control panel. Unlike heat dissipation fans, using the control panel in a sealed state enables heat dissipation while keeping it dustproof, providing a more reliable heat management solution. At Apiste, we offer two types of heat exchangers: heat pipe type and plate type. The heat pipe type achieves ultra-high efficiency and miniaturization through "super thermal conductive pipes." The plate type enables efficient heat dissipation with the "next-generation heat dissipation module." The documentation includes more detailed features, specifications, and dimensional drawings, so if you are interested, please download the PDF from the related catalog below or feel free to contact us. [Contents Included] ■ Lineup of ENH series heat exchangers for control panels ■ Features of heat pipe type heat exchangers ■ Features of plate type heat exchangers ■ Specifications ■ Dimensional drawings ■ Standard panel cut drawings
Introducing non-fluorocarbon models in the lineup of "local air conditioning units" that condition limited spaces! Achieve energy savings along with high-precision management of temperature, humidity,...
- Temperature and Humidity Control
[Case Study of Solution Proposal] Humidity management suppresses the adhesion of foreign substances due to static electricity!
This is a case that is possible precisely because Apiste specializes in both environmental improvement and precision air conditioning and temperature control. There was a customer in a factory producing precision parts who experienced a high number of defects due to foreign substances adhering to coiled metal before it was pressed, caused by static electricity. Apiste proposed a localized air conditioning system, stabilizing the temperature and humidity in the production area to create an environment less prone to static electricity. 【Solution Proposal Case】 ■ Conventional Method - Use of general air conditioning ■ Issues - Static electricity occurs in winter, causing foreign substances to adhere to the workpieces. - If the workpieces enter the press with foreign substances attached, they become defective products. ■ Ideal State - Suppression of static electricity generation, preventing foreign substances from adhering. ■ Apiste's Proposal - Installation of the PAU series precision air conditioning units along with booths and fan filter units to implement localized air conditioning. ■ Benefits - Control of humidity to suppress the generation of static electricity. - Stabilizing temperature and humidity only in the necessary areas minimizes initial costs. - Additionally, measures to prevent the intrusion of foreign substances are also realized.
It's now common for oil chillers to be non-Freon! It's possible to eliminate the cost burden associated with Freon.
- Chiller
[Case Study of Solution Proposal] Implemented oil temperature management for hydraulic units, achieving stable operation of equipment! Easy explanation in 6 pages of manga!
This is a case that is possible precisely because Apiste handles both environmental improvement and air conditioning/temperature control. It would be problematic if the oil temperature rises and the hydraulic unit becomes overheated, causing production to stop. An increase in oil temperature can lead to seal degradation and pump failure. 【Proposed Solution Case】 ■ Conventional Method - Use of a natural cooling hydraulic unit ■ Issues - During summer and other times of high outside temperatures, the cooling efficiency decreases, leading to an increase in oil temperature - Oil leaks occur due to seal degradation - High maintenance costs due to pump failures ■ Ideal Condition - The oil temperature of the hydraulic unit is maintained below a certain temperature year-round - No oil leaks occur - Pumps do not frequently fail - Production is not halted due to pump replacement maintenance ■ Apiste's Proposal - Installation of the compressor-type oil chiller VSC-N series ■ Benefits - Realization of oil temperature management - Resolution of oil leaks caused by seal degradation - Reduction in time and costs for pump replacement +α Implementation of preventive maintenance with external output for oil temperature alarms (IoT compatible) *For more details, please refer to the related product catalog or feel free to contact us.
Equipped with a dashcam function! Automatically records temperature and errors, which can be used for troubleshooting in case of emergencies.
- Chiller
[New Chiller Catalog Now Available] Introducing the Apiste Chiller lineup!
Introducing our comprehensive lineup of chillers that meet all your needs! ■ Non-Freon Chiller PCU-NE Series - Uses non-Freon refrigerant R1234yf, exempt from the Freon emission suppression law - Industry-first drive recorder and time calendar function ■ Wide Range Chiller PCU-R Series - Wide range of -10 to 80℃ - Class-leading accuracy of ±0.05℃ ■ High Durability Chiller PCU-SL Series - Does not stop even in high-temperature environments - Usable outdoors
Introduction to the application guide featuring temperature control for molds and cooling for welding machines!
- Chiller
Introducing applications such as temperature management in the sheet extrusion process and cooling of mixers and tanks!
- Chiller
High-Performance Chiller Application Guide for the Chemical and Resin Industry Now Available
We have published an application guide for the chemical and resin industry that leverages the features of our high-performance chiller, the "PCU-SL Series." This document introduces applications for the chemical and resin industry using our high-performance chiller, the "PCU-SL Series." We will solve various traditional problems in applications such as temperature management in sheet extrusion processes, coating and lamination processes, and temperature control of molds with the high-performance chiller "PCU-SL Series"! We have presented the information clearly with illustrations, so if you are interested, please download the PDF from the related catalog below or feel free to contact us. [Contents] ■ Temperature management in sheet extrusion processes ■ Temperature management in coating and lamination processes ■ Cooling of the water tank for extruders ■ Temperature control of molds ■ Cooling of stirrers and tanks
Introducing applications such as cooling for X-ray inspection equipment!
- Chiller
Publication of the 'High-Performance Chiller Application Guide' for the steel and non-ferrous metal industry.
We have published an application guide for the steel and non-ferrous metal industries that leverages the features of our high-performance chiller, the "PCU-SL Series." This document introduces applications for the steel and non-ferrous metal industries using our high-performance chiller, the "PCU-SL Series." We will solve various conventional problems in applications such as cooling X-ray inspection equipment, plasma seam welding machines, and temperature management for laser processing machines with the high-performance chiller "PCU-SL Series"! We have presented this information clearly with illustrations, so if you are interested, please download the PDF from the related catalog below or feel free to contact us. [Contents] ■ Cooling of X-ray inspection equipment ■ Temperature management of laser processing machines ■ Cooling of plasma seam welding machines ■ Cooling of rolls/bearings/hydraulic units ■ Cooling of high-frequency induction heating devices
An explanation of the differences between disk-type, filter-type, and cyclone-type mist collectors in manga format! *Manga materials will be provided.
- Oil Mist Collector
"Manga Material 'Improving the Oil Mist Environment! "Mist Collector Polar"' Now Available" Easy to read in manga format! An explanation about mist collectors!
We have published a document titled "Improving Oil Mist Environments! 'Mist Collector Polar'" which explains mist collectors in an easy-to-understand manga format. Are you struggling with oil mist not being fully collected due to filter clogging in your mist collector? In this document, we introduce the "GME Series" mist collector, which maintains its collection effectiveness even without long-term maintenance. We also explain the different types of mist collectors and the structural differences among them, so if you're interested, please download the PDF from the related catalog below or feel free to contact us. [Contents] ■ Explanation of issues with filter-type and cyclone-type collectors ■ Features of disc-type collectors
Contributing to the improvement of line operating rates and the reduction of unexpected repairs for control equipment! A simple explanation in 6 pages of manga.
- Control Panel Cooler
Achieve significant energy savings! Non-Freon energy-saving control panel cooler ENC-GR-eco series.
The cooler for control panels can perform cooling, dust prevention, and dehumidification inside the panel due to its internal circulation method. It keeps the equipment inside the manufacturing site in optimal condition, enabling stable production. This time, we would like to introduce the non-fluorocarbon energy-saving control panel cooler "ENC-GR-eco series." ■ Since it uses non-fluorocarbon refrigerants, there are no management costs for fluorocarbons! The global warming potential (GWP) is extremely low, and it is not subject to the fluorocarbon emission control law, so there are no costs for recovering or destroying the fluorocarbons from discarded coolers, and there is no obligation for regular inspections of the cooler during use. ■ Energy-saving operation is possible! By operating according to the load rate, we have achieved energy savings of up to 55% compared to conventional models. In addition to controlling the "condensation fan" and "electronic expansion valve," we also implement "compressor control" using a uniquely developed inverter. ■ Lightweight and slim for easy installation! We have achieved a significant weight reduction of up to 32% compared to our conventional models. Additionally, we have models with a slim depth of 115mm, making installation in narrow spaces possible! If you are interested, please feel free to contact us.
Localized air conditioning manages temperature and humidity only where needed! The trend is shifting from whole-building air conditioning to localized air conditioning.
- air conditioning
【Amazing Dehumidification Ability!】Instant dry air supply possible with just the cooler! The "PAU-AZ2000SE-DR" can be used as a drive booth or dry air supply unit.
Precision air conditioning units enable energy-efficient and highly accurate management of temperature, humidity, and cleanliness through "local air conditioning," which conditions only limited spaces. This time, we would like to introduce the precision air conditioning unit specialized in dehumidification, the "PAU-AZ2000SE-DR"! The PAU-AZ2000SE-DR adopts Apiste's unique "MAX-DRY operation method," allowing for dehumidification of absolute moisture content by ▲65% using only the refrigeration cycle, which was previously considered difficult. For example, it can dehumidify intake air from 27°C and 70% humidity to 23°C and 30% humidity in a short time after starting operation. It can also be used for applications that previous precision air conditioning units could not accommodate, so if you are interested, please feel free to contact us. 【Application Examples】 - As a dry air conditioning unit when using hygroscopic materials! - As a drive booth for processes using organic solvents or powders! - As a dry air supply unit for the OA intake of air conditioning equipment!
The non-drain type control panel cooler "ENC-GR-LE-eco series" can be used in sites where drainage water treatment is difficult.
- Control Panel Cooler
Achieving non-drainage even in high temperature and humidity environments! The 'ENC-GR-LE-eco series' can be used in sites where drain water treatment is difficult!
The cooler for control panels can perform cooling, dust prevention, and dehumidification inside the panel due to its internal circulation method. It keeps the equipment inside the manufacturing site in optimal condition, ensuring stable production. The "ENC-GR-LE-eco series" has achieved a non-drain system even in high-temperature and high-humidity environments. It uses a special evaporative filter with excellent water absorption and air permeability, which vaporizes drain water using the heat discharged by the cooler. ■ Non-drain system using a special evaporative filter! It has achieved a non-drain system even in high-temperature and high-humidity environments of 35°C and 85% humidity. ■ Since it uses non-fluorocarbon refrigerants, there are no management costs for fluorocarbons! With an extremely low global warming potential (GWP), it is exempt from the Fluorocarbon Emission Control Law, eliminating the costs for recovering or destroying fluorocarbons from discarded coolers, and there is no obligation for regular inspections of the cooler during use. ■ Energy-saving operation By operating according to the load rate, it has achieved energy savings of up to 55% compared to conventional systems. It employs "compressor control" through a uniquely developed inverter. If you are interested, please feel free to contact us.
High precision of ±0.1℃ is ideal for spindle cooling and hydraulic cooling of high-precision machine tools! Since it is non-Freon, the cost of managing Freon is eliminated.
- Chiller
[Free Distribution - 48 Pages] A comprehensive explanation of the overview and principles of industrial air conditioning, as well as how to interpret the figures used for performance comparisons. For ...
- air conditioning
◆◆Currently offering free access to the material that won 1st place in the catalog rankings◆◆ "Basic Knowledge of Industrial Air Conditioning & Improvement Case Studies" ◆◆
Did you know that the theme of temperature, such as "cooling and heating," which is essential in the manufacturing field, is closely related to "air conditioning"? This document is a comprehensive compilation of knowledge related to industrial air conditioning, cooling, and heating. It also explains related topics such as the properties of air, refrigerants, and air diagrams. If you are interested, please feel free to download the PDF from the related catalog below or contact us. 【Contents (excerpt)】 ■ Overview of air conditioning ■ Properties of air ■ Principles of air conditioning ■ Refrigerants ■ Refrigeration cycle of air conditioning units ■ Air diagrams ■ Air conditioning unit's airflow capacity and pressure loss
■Temperature control range: -10 to 80℃ ■Control accuracy: ±0.05℃ This is a compact chiller that achieves a wide temperature range and high precision.
- Chiller
Automatic cleaning of the filter! By performing it at the optimal timing, we can maintain high dust collection capability.
- Dust collector
◆◆Free Progressing◆◆ Latest technical document "Basic Dust Control Measures" *Also ideal for welding fume control!
"The Basics of Dust Control" explains the fundamental knowledge related to dust for those engaged in work environments where dust is generated. It covers appropriate dust control measures to maintain health and comfort at work, including knowledge about dust, regulations, methods for suppressing and removing dust, and other essential information related to dust. It also includes details about the revision of specific regulations in April 2021. This book summarizes dust control measures to prevent health disorders, so if you are interested, please download the PDF from the related catalog below or feel free to contact us. [Contents (Excerpt)] ■ Health disorders caused by dust ■ Dust control measures ■ Management of dust-related work ■ Regulations concerning dust ■ About the revision of specific regulations in April 2021 (welding fumes)
An Apiste engineer explains. We will provide an overview of the relevant regulations regarding the use of dust collectors and the response flow for welding fumes under the special regulations.
- Technical Seminar
An Apiste technician explains. We will convey how to read the "air line diagram," which helps understand the properties of air.
- Technical Seminar
The GDE series dust collectors do not require filter replacement for a long time and can operate in an energy-saving mode, reducing maintenance and running costs.
- Dust collector
Long-term filter replacement is unnecessary, reducing maintenance costs. The Apiste dust collector GDE series allows you to quickly understand operating conditions.
- Dust collector
Long-term filter replacement-free × Easily understand operating conditions - Apiste's dust collector GDE series
- Dust collector
The cooler for control panels will solve your problems with the deterioration and failure of control equipment! [Immediate delivery]
- Control Panel Cooler
Long-term filter replacement not required × Easily understand operating conditions - Apiste's dust collector GDE series
- Dust collector
Simply place and connect to easily achieve precise air conditioning. The Apiste PAU series of precision air conditioning units allows for flexible temperature control in enclosed spaces.
- Dust collector
Just by placing and connecting, you can easily achieve precise air conditioning. The Apiste PAU series of precision air conditioning units allows for flexible temperature control in enclosed spaces.
- Dust collector
Simply place and connect to easily achieve precise air conditioning. The Apiste PAU series of precision air conditioning units allows for flexible temperature control in enclosed spaces.
- Other clean room equipment and facilities
Simply place and connect to easily achieve precise air conditioning. The Apiste PAU series of precision air conditioning units allows for flexible temperature control in enclosed spaces.
- Other clean room equipment and facilities
Long-term filter replacement is unnecessary, reducing maintenance costs. The Apiste dust collector GDE series allows you to quickly understand the operating status.
- Dust collector
The VSC series oil chillers, which use non-Freon refrigerants, are exempt from the Freon Emission Control Law and can achieve high-precision oil temperature management with an accuracy of ±0.1°C.
- Chiller
The VSC series oil chillers, which adopt non-Freon refrigerants, are exempt from the Freon Emission Control Law and can achieve high-precision oil temperature management within ±0.1℃.
- Chiller