List of Measurement and Analysis products

  • classification:Measurement and Analysis

6346~6390 item / All 52910 items

Displayed results

Reduce the workload from handling heavy objects! Here are five case studies that solved customer challenges! We are also accepting free consultations and tests tailored to your work!

  • PRエリア.png
  • Other conveying machines

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Presentation of explanatory materials on JIS and ISO standards. We propose suitable safety barriers from a rich product series! Free rental of demo kits.

  • Satech - AdaptaGuard_Ipros_2023_JP_1.jpg
  • Satech - BlueGuard_Ipros_2023_JP_1.jpg
  • Satech - EasyGuard_Ipros_2023_JP_1.jpg
  • Satech - FastGuard_Ipros_2023_JP_2.jpg
  • Satech - ImpactGuard_Ipros_2023_JP_1.jpg
  • Satech - EasyGuard_Ipros_2023_JP_Media-gallery_1.jpg
  • Satech - ImpactGuard_Ipros_2023_JP_Media-gallery_2.jpg
  • Satech - AdaptaGuard_Ipros_2023_JP_Media-gallery_1.jpg
  • Satech - BlueGuard_Ipros_2023_JP_Media-gallery_2.jpg
  • Other safety and hygiene products

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Reproducing temperature stress during transportation! Evaluating the presence or absence of delamination and cracks through heat treatment.

  • Testing Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Measurable contrast ratio and color temperature! Quantitative evaluation of changes in optical properties.

  • Spectroscopic Analysis Equipment
  • Contract measurement

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration
R0012 メイン画像.png

Spectral radiance and chromaticity evaluation of liquid crystal displays.

Our company can measure the optical properties of LCD displays and OLEDs using a spectroradiometer. By conducting measurements before and after testing, we can quantitatively evaluate changes in optical properties. Spectral radiance is measured in four patterns: white, red, green, and blue. It is possible to measure various optical properties such as luminance, chromaticity, and dominant wavelength. *For more details about the products, please refer to the product page and catalog below.

When a substance undergoes a phase transition due to a temperature change, a change in thermal energy occurs.

  • Contract measurement

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration
shape memory alloy.png

Measurement of the transformation temperature of shape memory alloys.

When a substance undergoes a phase transformation due to a change in temperature, a change in thermal energy occurs. Shape memory alloys are alloys that have the property of returning to their original shape when deformed and heated above a specific temperature. The manifestation of shape memory is due to a phase transformation (martensitic transformation). By capturing the thermal energy change during the transformation using DSC, we measured the transformation temperatures of three types of shape memory alloy products and investigated the relationship with their composition through elemental analysis. When a deformed wire is immersed in hot water, it instantly returns to its original shape.

Observe the state of the compound from the direction of the back and the surface! We will consider and propose processing, pretreatment, observation methods, and combinations.

  • Contract Analysis
  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration
observation of compounds_etching.png

Examples of observing intermetallic compounds through etching treatment.

The method of processing the observation samples may result in different information being obtained. You may have observed the solder joints in two dimensions from a cross-section, but have you ever wondered how the compounds are growing in three dimensions? In this document, we present examples of observations of the Cu pad and solder joint. We include both "cross-sectional observation" and "planar observation." For more details, please refer to the related products and catalogs below.

Automobiles, paints, construction, plastics, printed materials, textiles, etc.! They are adopted as tests in various fields.

  • Testing Equipment and Devices
  • Weather resistance test
  • Environmental Test Equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration
メイン画像:R0014 図.png

Accelerated Weathering Test <Xenon Weather Meter>

The "Xenon Weather Meter" is an accelerated weathering test device that uses a xenon arc lamp as its light source. By combining exposure conditions such as irradiation, temperature and humidity, and rainfall, it artificially reproduces outdoor and indoor environments, allowing for the evaluation of weather resistance and light resistance of test specimens in a shorter time than natural exposure tests. The xenon lamp used as the light source has a spectral distribution that closely approximates the ultraviolet and visible parts of sunlight, with precise control over the use of appropriate filters and irradiance. This enables tests with good correlation and reproducibility to outdoor exposure. This testing is conducted as a service by our partner companies. For more detailed information, please refer to related products and catalogs.

Send compressed air at the specified pressure and hold for a set time! Check for any leaks.

  • Testing Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration
R0016 画像.png

Pressure Repeated Test

The "Pressure Repetition Test" involves supplying compressed air at a specified pressure to products that require airtightness, in order to check for any leaks. It is also possible to conduct a durability test that alternates between pressurized and released states, and this can be performed in a heated state in combination with an environmental testing chamber. Additionally, it is possible to confirm the timing of any leaks from the logged pressure data.

It is also possible to create master curves in tensile, shear, and bending modes other than compression mode!

  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration
?extensometer.png

Evaluation of tensile properties using a stretch gauge for high-stretch flexible materials.

We would like to introduce the "Tensile Property Evaluation using Extensometers for High-Elasticity Flexible Materials" that we offer. Tensile tests of NR rubber will be conducted using contact-type (suitable for high-elasticity and soft materials) and non-contact type (video) extensometers, and the results will be compared. To accurately determine strain in tensile tests, it is necessary to select the appropriate extensometer and testing conditions based on the target material and measurement objectives. We will provide suggestions tailored to your consultation needs.

Spectroscopic analysis is suitable for component analysis and qualitative analysis of foreign substances.

  • powder spectrum_raman_ftir.png
  • Testing Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration
?chemical analysis.png

Chemical Analysis Concierge Service

We would like to introduce our "Chemical Analysis - Trust Us Service." When conducting component analysis of foreign substances or stains on products, it can be challenging to determine whether organic analysis or inorganic analysis is more suitable, and which specific analysis within organic or inorganic is the most appropriate. We provide a comprehensive service for customers who are struggling with the selection of analysis methods. Since each analysis device can measure different targets, it is necessary to choose a method that fits the purpose based on the information available.

The purity of the electrolyte greatly affects the performance of the battery! It suppresses the volatility of sulfur components and converts them into a form that can be detected by IC.

  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration
ICP Luminescence analysis.png

Composition analysis of LIB cathode active materials by ICP luminescence analysis.

This presentation introduces the composition analysis of active materials in cathode materials using ICP emission analysis. The cathode material in lithium-ion batteries (LIB) is one of the important components that influence the battery's voltage and energy density, and the composition of the cathode material significantly affects the battery's performance. ICP emission analysis allows for qualitative and quantitative analysis of approximately 70 elements, primarily metal elements. In addition to composition analysis of LIB cathode materials, it can also be applied to various analyses, including qualitative and quantitative analysis of additives and impurities contained in samples, as well as quantitative analysis of substances regulated by the RoHS directive.

Industry standard that vividly reveals potential defects in solar cells, EL image inspection device PVX330.

  • Microscope
  • Image analysis software
  • Defect Inspection Equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Microscopic PL observation of the fine structure of wafers in the solar cell manufacturing process.

  • Image Processing Equipment
  • Defect Inspection Equipment
  • Contract measurement

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

The String Checker SZ-200 can identify solar panel failures on a string-by-string basis.

  • Other inspection equipment and devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

We conduct environmental testing, as well as non-destructive observation and electrical property measurements.

  • Analytical Equipment and Devices
  • Analysis Services

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration
microscope_vhx-x1.jpg

Appearance observation and measurement services

We would like to introduce our "Appearance Observation and Measurement Service." We are equipped with a variety of devices to meet your needs, including appearance observation before and after reliability testing, solder joint observation, as well as dimensional measurements and surface roughness measurements of various components. You can also leave the pre-observation processing to us. Our company has IPC-certified IPC specialists on staff. We provide assistance with observations, consultations, and solutions to various observation-related concerns in accordance with international standards.

Inspection equipment effective for initial observation of various components and materials, including implementation substrates and electronic parts.

  • image_02.jpg
  • image_03.jpg
  • image_10.jpg
  • image_11.jpg
  • image_02.jpg
  • image_04.jpg
  • image_03.jpg
  • X-ray inspection equipment
  • Other inspection equipment and devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Introducing a new device! We present an analytical method aimed at the qualitative and quantitative analysis of components contained in samples.

  • 2019-10-10_17h36_48.png
  • Analytical Equipment and Devices
  • Contract Analysis

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration
?chemical analysis.png

Chemical Analysis Concierge Service

We would like to introduce our "Chemical Analysis - Trust Us Service." When conducting component analysis of foreign substances or stains on products, it can be challenging to determine whether organic analysis or inorganic analysis is more suitable, and which specific analysis within organic or inorganic is the most appropriate. We provide a comprehensive service for customers who are struggling with the selection of analysis methods. Since each analysis device can measure different targets, it is necessary to choose a method that fits the purpose based on the information available.

Two high-power constant temperature and humidity chambers have been introduced! Ideal for temperature cycle tests and temperature and humidity cycle tests for automotive parts and more.

  • image_1944.png
  • Contract measurement
  • Contract Analysis
  • Contract Inspection

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration
gear oven.png

Rubber heat aging test

Our company conducts "rubber thermal aging tests" that help evaluate the properties of materials in actual usage environments. Using a method compliant with JIS K6257 (Method for determining thermal aging characteristics of vulcanized rubber and thermoplastic rubber), rubber test pieces are suspended in a gear oven to create specimens with varying heat treatment times. Additionally, tensile tests are performed on heated natural rubber (NR) to investigate changes in mechanical properties, while hardness is measured simultaneously. Changes in the characteristics of the rubber are also examined, confirming that rubber elasticity is lost and the material becomes harder with heating.

X-ray CT observation allows for the assessment of the winding condition of coil wiring! We will introduce examples of observing IC-type coils, which differ from X-ray transmission observation.

  • image_14.png
  • image_15.png
  • image_16.png
  • X-ray inspection equipment
  • Other inspection equipment and devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration
case.png

Analysis case of faulty switch contacts

Since a malfunction was suspected in the switch section of the appliance that would not power on, we will introduce a case study along with the work flow. First, we check for any shape changes such as swelling, cracking, or discoloration through visual observation. In the electrical check, we confirm whether the malfunction can be reproduced and whether it is an open or short circuit. An internal observation using X-rays revealed that the contact terminals inside the switch had melted, scattered, and disappeared, resulting in an open failure. Ultimately, we will submit a report that includes the consideration of the cause. We also accept inquiries for analysis consultations after non-destructive testing, so please feel free to contact us.

[Comparison images available] Internal shape abnormalities can also be observed non-destructively! We compared X-ray CT and cross-sectional SEM.

  • image_18.png
  • image_19.png
  • X-ray inspection equipment
  • Other inspection equipment and devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

X-ray fluoroscopy observation, oblique CT observation, orthogonal CT observation, etc.! Introduction of BGA solder crack analysis cases.

  • 2.jpg
  • 3.jpg
  • 4.jpg
  • X-ray inspection equipment
  • Other inspection equipment and devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration
case.png

Analysis case of faulty switch contacts

Since a malfunction was suspected in the switch section of the appliance that would not power on, we will introduce a case study along with the work flow. First, we check for any shape changes such as swelling, cracking, or discoloration through visual observation. In the electrical check, we confirm whether the malfunction can be reproduced and whether it is an open or short circuit. An internal observation using X-rays revealed that the contact terminals inside the switch had melted, scattered, and disappeared, resulting in an open failure. Ultimately, we will submit a report that includes the consideration of the cause. We also accept inquiries for analysis consultations after non-destructive testing, so please feel free to contact us.

[Video Available] Captured the moment of defect occurrence! Introducing a case of X-ray observation using LED.

  • 2.jpg
  • 3.jpg
  • 4.jpg
  • X-ray inspection equipment
  • Other inspection equipment and devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Numerous examples of "BGA solder crack analysis," "surface mount LEDs," and "chip resistor observation" using X-ray fluoroscopy and angled CT observation are included!

  • X-ray inspection equipment
  • Contract Inspection
  • Contract Analysis

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

We offer a variety of measurement modes, including double cantilever beam bending and three-point bending with free support!

  • image_02.png
  • image_03.png
  • Contract measurement
  • Contract Analysis
  • Weight related measuring instruments

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration
?chemical analysis.png

Chemical Analysis Concierge Service

We would like to introduce our "Chemical Analysis - Trust Us Service." When conducting component analysis of foreign substances or stains on products, it can be challenging to determine whether organic analysis or inorganic analysis is more suitable, and which specific analysis within organic or inorganic is the most appropriate. We provide a comprehensive service for customers who are struggling with the selection of analysis methods. Since each analysis device can measure different targets, it is necessary to choose a method that fits the purpose based on the information available.

Observe the degree of endothermic/exothermic reaction of the sample! The temperature range is possible from -90°C to 550°C.

  • Contract measurement
  • Contract Analysis

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration
?chemical analysis.png

Chemical Analysis Concierge Service

We would like to introduce our "Chemical Analysis - Trust Us Service." When conducting component analysis of foreign substances or stains on products, it can be challenging to determine whether organic analysis or inorganic analysis is more suitable, and which specific analysis within organic or inorganic is the most appropriate. We provide a comprehensive service for customers who are struggling with the selection of analysis methods. Since each analysis device can measure different targets, it is necessary to choose a method that fits the purpose based on the information available.

The analysis sensitivity of TOF-SIMS is high at the ppm level, making it effective for analyzing trace contamination!

  • 2020-05-28_17h35_40.png
  • 2020-05-28_17h35_42.png
  • 2020-05-28_17h35_48.png
  • Contract Analysis
  • Contract Inspection
  • Contract measurement

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration
?chemical analysis.png

Chemical Analysis Concierge Service

We would like to introduce our "Chemical Analysis - Trust Us Service." When conducting component analysis of foreign substances or stains on products, it can be challenging to determine whether organic analysis or inorganic analysis is more suitable, and which specific analysis within organic or inorganic is the most appropriate. We provide a comprehensive service for customers who are struggling with the selection of analysis methods. Since each analysis device can measure different targets, it is necessary to choose a method that fits the purpose based on the information available.

High-resolution imaging with a micro probe! Achieving nano-level structural analysis.

  • 2020-05-28_17h35_56.png
  • 2020-05-28_17h35_59.png
  • 2020-05-28_17h36_03.png
  • 2020-05-28_17h36_06.png
  • Contract Analysis
  • Contract measurement
  • Other microscopes

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Depth-direction measurements using Raman spectroscopy! Material analysis of each layer is possible from the surface of multilayer films.

  • image_02.png
  • image_03.png
  • Spectroscopic Analysis Equipment
  • Analytical Equipment and Devices
  • Contract Analysis

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration
?Observation of tire cross section.jpg

Cryogenic ion milling cross-section processing example (rubber products)

We will introduce a case where cross-sections were created and observed by method regarding the adhesive parts of the tires of pull-back cars. When conducting SEM observations of the created cross-sections, fillers present inside the rubber were confirmed. It was found that the dispersion state of the fillers and the condition of the adhesive interface were not clear with fracture by liquid nitrogen or mechanical polishing. In contrast, the cross-sections created by cryo ion milling allow for clear observation of the dispersion state of the fillers contained within the rubber and the condition of the adhesive interface with the plastic substrate.

Applicable to change observation, with support for additional analysis! We evaluate the subject in a time series and non-destructive manner.

  • image_02.png
  • image_03.png
  • Contract Inspection
  • Testing Equipment and Devices
  • Other inspection equipment and devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration
?pusher.png

Observation of substrate deformation using a 3D shape measuring device (VR-6200)

I would like to introduce "Observation of Substrate Deformation Using a 3D Shape Measuring Machine." By applying pressure to the PCB substrate, referencing bending tests of plastics and PCB substrates, the change in state is measured using a 3D shape measuring machine (VR-6200). Since the measurement results can be confirmed with a color palette and line profile, it is possible to visually verify the shape and amount of deformation caused by the applied pressure.

We will introduce an example of analysis using EBSD for screws (Cu2Zn).

  • image_08.png
  • image_09.png
  • image_11.png
  • image_01.png
  • image_02.png
  • image_03.png
  • image_04.png
  • image_05.png
  • image_06.png
  • Analytical Equipment and Devices
  • Analysis Services

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration
Phasemap.png

Example of analysis of compounds at the SAC solder and Ni pad interface.

We will introduce an example of the analysis of compounds formed at the interface between Sn-Ag-Cu solder and NiP pads. At the interface of NiP pads and Sn-Ag-Cu solder, compounds such as (Ni,Cu)3Sn4 and (Cu,Ni)6Sn5 grow, and surface analysis using EDX shows the distribution of Ni, Cu, and Sn within these compounds. The EBSD method is a technique that analyzes based on the crystallographic information of the sample. By combining it with elemental analysis using EDX, it is possible to estimate the composition, and in some cases, it may be possible to analyze using crystallographic data for Ni3Sn4 and Cu6Sn5 as substitutes.

Visualize the features that appear in the graph! You can check the distribution of crystal sizes and the orientation of crystal directions.

  • image_02.png
  • image_03.png
  • image_04.png
  • image_05.png
  • Analytical Equipment and Devices
  • Analysis Services

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration
Phasemap.png

Example of analysis of compounds at the SAC solder and Ni pad interface.

We will introduce an example of the analysis of compounds formed at the interface between Sn-Ag-Cu solder and NiP pads. At the interface of NiP pads and Sn-Ag-Cu solder, compounds such as (Ni,Cu)3Sn4 and (Cu,Ni)6Sn5 grow, and surface analysis using EDX shows the distribution of Ni, Cu, and Sn within these compounds. The EBSD method is a technique that analyzes based on the crystallographic information of the sample. By combining it with elemental analysis using EDX, it is possible to estimate the composition, and in some cases, it may be possible to analyze using crystallographic data for Ni3Sn4 and Cu6Sn5 as substitutes.

The EBSD method allows for the estimation of crystal states and residual stresses! Here is an example of BGA analysis.

  • image_02.png
  • image_03.png
  • image_04.png
  • image_05.png
  • image_06.png
  • Analytical Equipment and Devices
  • Analysis Services

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration
Phasemap.png

Example of analysis of compounds at the SAC solder and Ni pad interface.

We will introduce an example of the analysis of compounds formed at the interface between Sn-Ag-Cu solder and NiP pads. At the interface of NiP pads and Sn-Ag-Cu solder, compounds such as (Ni,Cu)3Sn4 and (Cu,Ni)6Sn5 grow, and surface analysis using EDX shows the distribution of Ni, Cu, and Sn within these compounds. The EBSD method is a technique that analyzes based on the crystallographic information of the sample. By combining it with elemental analysis using EDX, it is possible to estimate the composition, and in some cases, it may be possible to analyze using crystallographic data for Ni3Sn4 and Cu6Sn5 as substitutes.

We will introduce an example of crystal analysis of intermetallic compounds at solder joints.

  • image_02.png
  • image_03.png
  • image_04.png
  • image_05.png
  • image_06.png
  • Analytical Equipment and Devices
  • Analysis Services

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration
Phasemap.png

Example of analysis of compounds at the SAC solder and Ni pad interface.

We will introduce an example of the analysis of compounds formed at the interface between Sn-Ag-Cu solder and NiP pads. At the interface of NiP pads and Sn-Ag-Cu solder, compounds such as (Ni,Cu)3Sn4 and (Cu,Ni)6Sn5 grow, and surface analysis using EDX shows the distribution of Ni, Cu, and Sn within these compounds. The EBSD method is a technique that analyzes based on the crystallographic information of the sample. By combining it with elemental analysis using EDX, it is possible to estimate the composition, and in some cases, it may be possible to analyze using crystallographic data for Ni3Sn4 and Cu6Sn5 as substitutes.

Observe the changes before and after compression on the copper plate! You can compare the half-life of the crystal grain size before and after compression.

  • image_02.png
  • image_03.png
  • image_04.png
  • image_05.png
  • Analytical Equipment and Devices
  • Analysis Services

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration
Phasemap.png

Example of analysis of compounds at the SAC solder and Ni pad interface.

We will introduce an example of the analysis of compounds formed at the interface between Sn-Ag-Cu solder and NiP pads. At the interface of NiP pads and Sn-Ag-Cu solder, compounds such as (Ni,Cu)3Sn4 and (Cu,Ni)6Sn5 grow, and surface analysis using EDX shows the distribution of Ni, Cu, and Sn within these compounds. The EBSD method is a technique that analyzes based on the crystallographic information of the sample. By combining it with elemental analysis using EDX, it is possible to estimate the composition, and in some cases, it may be possible to analyze using crystallographic data for Ni3Sn4 and Cu6Sn5 as substitutes.

We will introduce an example of the analysis of EBSD patterns (Kikuchi patterns) at gold wire bond joints.

  • image_02.png
  • image_03.png
  • image_04.png
  • image_05.png
  • Analytical Equipment and Devices
  • Analysis Services

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration
Phasemap.png

Example of analysis of compounds at the SAC solder and Ni pad interface.

We will introduce an example of the analysis of compounds formed at the interface between Sn-Ag-Cu solder and NiP pads. At the interface of NiP pads and Sn-Ag-Cu solder, compounds such as (Ni,Cu)3Sn4 and (Cu,Ni)6Sn5 grow, and surface analysis using EDX shows the distribution of Ni, Cu, and Sn within these compounds. The EBSD method is a technique that analyzes based on the crystallographic information of the sample. By combining it with elemental analysis using EDX, it is possible to estimate the composition, and in some cases, it may be possible to analyze using crystallographic data for Ni3Sn4 and Cu6Sn5 as substitutes.

Achieve high processing precision and a wide processing area! Machining is also possible while reducing damage with cooling functions.

  • 2020-08-05_09h56_52.png
  • 2020-08-05_09h58_01.png
  • 2020-08-05_09h58_23.png
  • 2020-08-05_09h59_16.png
  • 2020-08-05_09h59_33.png
  • Contract Inspection
  • Processing Contract

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration
?Observation of tire cross section.jpg

Cryogenic ion milling cross-section processing example (rubber products)

We will introduce a case where cross-sections were created and observed by method regarding the adhesive parts of the tires of pull-back cars. When conducting SEM observations of the created cross-sections, fillers present inside the rubber were confirmed. It was found that the dispersion state of the fillers and the condition of the adhesive interface were not clear with fracture by liquid nitrogen or mechanical polishing. In contrast, the cross-sections created by cryo ion milling allow for clear observation of the dispersion state of the fillers contained within the rubber and the condition of the adhesive interface with the plastic substrate.

You can closely observe the solder joint condition of electronic components on the implementation board and the internal structure of the components!

  • 2020-08-05_10h25_01.png
  • 2020-08-05_10h25_13.png
  • Other contract services
  • Contract Inspection

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration
?sensor parts.png

Observation of tracking camera cross-section by mechanical grinding.

I would like to introduce "Cross-sectional observation of tracking camera using mechanical polishing." Regarding the structure of the tracking camera components, when viewed from above, the lens can be identified. Although it cannot be clearly seen in the X-ray image, the lens is incorporated into the convex part. Additionally, the cross-sectional structure is similar to that of an RGB sensor, featuring a back-illuminated CMOS structure. However, since color information is not necessary for the tracking camera, there is no color filter layer. A jagged uneven shape was observed on the surface of the photodiode.

Pre-processing of SiC devices → Identification of leakage points → Physical analysis/component analysis handled seamlessly!

  • 2020-08-18_15h02_00.png
  • 2020-08-18_15h02_24.png
  • 2020-08-18_15h01_55.png
  • Analysis Services
  • Contract Analysis

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration
TEM_TalosF200E.jpg

Announcement of the introduction of Talos F200E

Our company will introduce the FEI "Talos F200E" transmission electron microscope system. Compared to conventional models, the resolution for TEM and STEM has improved, and performance has been significantly enhanced, allowing for EDS analysis with four detectors. Additionally, it is equipped with features such as drift-corrected frame integration (DCFI), which accumulates multiple frames while correcting for drift.

Even with SiC power devices, we can provide consistent support for cross-section preparation of specific areas, observation of diffusion layer shapes, as well as wiring structure and crystal structure...

  • 2020-08-18_15h03_09.png
  • 2020-08-18_15h03_13.png
  • 2020-08-18_15h03_19.png
  • 2020-08-18_15h03_24.png
  • Analysis Services
  • Contract Analysis

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Check the quality status of LCD components and products! We will analyze the structures of the LCD panels using our analytical methods and expertise!

  • Analysis Services
  • Contract Analysis

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration
画像5.png

Observation of Conductive Particle Shape in COG Implementation

We will introduce the observation of the shape of conductive particles in COG implementation. ICs and liquid crystal panels are implemented using the COG method with ACF (anisotropic conductive film). A resin ball is used as the core, and a metal layer (such as nickel or gold) for conductivity is deposited on its surface. During connection, the particles deform appropriately to electrically connect the IC and the panel. To confirm the degree of particle deformation and connection status, cross-sectional observations were conducted, revealing that the particle deformation was at a "medium" level, indicating an appropriate degree of deformation. By examining the deformation of conductive particles from both the planar and cross-sectional directions, we can explore the correlation with display defects. Please feel free to contact us for any inquiries regarding panel-related defects.

We will handle everything from the evaluation of the diffusion layer to physical analysis/chemical analysis regarding the malfunctioning part!

  • image_03.png
  • image_02.png
  • image_05.png
  • image_06.png
  • image_04.png
  • image_07.png
  • image_08.png
  • image_09.png
  • image_11.png
  • Analysis Services
  • Contract Analysis
  • Semiconductor inspection/test equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration
TEM_TalosF200E.jpg

Announcement of the introduction of Talos F200E

Our company will introduce the FEI "Talos F200E" transmission electron microscope system. Compared to conventional models, the resolution for TEM and STEM has improved, and performance has been significantly enhanced, allowing for EDS analysis with four detectors. Additionally, it is equipped with features such as drift-corrected frame integration (DCFI), which accumulates multiple frames while correcting for drift.

Analysis of inorganic compounds such as metal oxides is also possible!

  • Analysis Services
  • Contract Analysis

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration
?chemical analysis.png

Chemical Analysis Concierge Service

We would like to introduce our "Chemical Analysis - Trust Us Service." When conducting component analysis of foreign substances or stains on products, it can be challenging to determine whether organic analysis or inorganic analysis is more suitable, and which specific analysis within organic or inorganic is the most appropriate. We provide a comprehensive service for customers who are struggling with the selection of analysis methods. Since each analysis device can measure different targets, it is necessary to choose a method that fits the purpose based on the information available.

Introducing a case study analyzing whiskers that occurred on the lead terminals of an IC package!

  • Other contract services
  • Contract Analysis
  • Analysis Services

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration
Phasemap.png

Example of analysis of compounds at the SAC solder and Ni pad interface.

We will introduce an example of the analysis of compounds formed at the interface between Sn-Ag-Cu solder and NiP pads. At the interface of NiP pads and Sn-Ag-Cu solder, compounds such as (Ni,Cu)3Sn4 and (Cu,Ni)6Sn5 grow, and surface analysis using EDX shows the distribution of Ni, Cu, and Sn within these compounds. The EBSD method is a technique that analyzes based on the crystallographic information of the sample. By combining it with elemental analysis using EDX, it is possible to estimate the composition, and in some cases, it may be possible to analyze using crystallographic data for Ni3Sn4 and Cu6Sn5 as substitutes.

At Omron's Yasu facility, which has a maximum 8-inch MEMS line, we respond to various customer requests from prototype to mass production in the wafer process!

  • Analysis Services
  • Contract Analysis

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

I confirmed the blocking function of polymer melting at high temperatures!

  • 2.jpg
  • 3.jpg
  • 4.jpg
  • 5.jpg
  • 6.jpg
  • 7.jpg
  • Other contract services
  • Contract Analysis

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration
ICP Luminescence analysis.png

Composition analysis of LIB cathode active materials by ICP luminescence analysis.

This presentation introduces the composition analysis of active materials in cathode materials using ICP emission analysis. The cathode material in lithium-ion batteries (LIB) is one of the important components that influence the battery's voltage and energy density, and the composition of the cathode material significantly affects the battery's performance. ICP emission analysis allows for qualitative and quantitative analysis of approximately 70 elements, primarily metal elements. In addition to composition analysis of LIB cathode materials, it can also be applied to various analyses, including qualitative and quantitative analysis of additives and impurities contained in samples, as well as quantitative analysis of substances regulated by the RoHS directive.

Light source for PL excitation compatible with 6-inch solar cells. By combining it with the EL image inspection device PVX series, PL observation becomes possible.

  • Image Processing Equipment
  • Image Processing Software
  • Defect Inspection Equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

The Solar Panel Checker SI-200 can easily detect faulty panels during operation.

  • Other inspection equipment and devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Filter

classification
Delivery Time
Location