List of Analysis Services products
- classification:Analysis Services
1~45 item / All 563 items
Reduce the workload from handling heavy objects! Here are five case studies that solved customer challenges! We are also accepting free consultations and tests tailored to your work!
- Other conveying machines
A belt grinding machine that has been in use for about 50 years since 1973. In addition to trust and proven results, the lineup is also extensive.
- Other machine tools

Belt grinding machine "Veda Machine" has high durability and a wide range of service parts.
The "Bader Machine" is our belt grinder that boasts excellent polishing performance for each individual unit. By selecting models and types according to the shape and size of the workpiece, and by equipping it with a polishing belt suitable for the task, it can flexibly accommodate a wide variety of items across various fields. Please make extensive use of it for high-efficiency polishing and grinding, reduction of work time, labor-saving, and standardization of tasks. 【Lineup】 ■ Portable type BP-K (air motor type) ■ Made-to-order machine PC-1 (wheel centerless), BC (standard dust cover) ■ Installed type BM (basic type), SBA-1, BH-2 ■ Wheel type SBD-4S, SBD-7, BWd *For more details, please download the PDF or contact us.
Propose, create, realize, that is SSIL.
- simulator
- Magnetic field analysis/electromagnetic wave analysis
- Analysis Services
Thorough support for design issue verification! Introducing our contract analysis and development solutions.
- Magnetic field analysis/electromagnetic wave analysis
- Contract Analysis
- Analysis Services
A solution that enables 100 times faster processing and analysis of models that are 10 times larger.
- Magnetic field analysis/electromagnetic wave analysis
- simulator
- Analysis Services
Solution through coil homogenization in Ritz line analysis
- Magnetic field analysis/electromagnetic wave analysis
- Contract Analysis
- Analysis Services
Introduction to the effects of interference between dq axes on inductance and torque.
- Magnetic field analysis/electromagnetic wave analysis
- PM motor
- Analysis Services
Introducing case studies of EMSolution! Detailed information on coupled analysis methods and more.
- Magnetic field analysis/electromagnetic wave analysis
- Analysis Services
- simulator
Introducing a case study of EMSolution! Impact load analysis of a servo motor.
- Magnetic field analysis/electromagnetic wave analysis
- Analysis Services
- Servo motor
Introducing analysis cases of EMSolution! Featuring plunger analysis models and more.
- Magnetic field analysis/electromagnetic wave analysis
- Analysis Services
- Contract Analysis
Introducing analysis cases of EMSolution! Detailed information on transformer analysis.
- Magnetic field analysis/electromagnetic wave analysis
- Contract Analysis
- Analysis Services
Electromagnetic field analysis specialists solve challenges - Support from solver development to contracted analysis.
- Analysis Services
- Contract Analysis
- Magnetic field analysis/electromagnetic wave analysis
Low-cost AC resistance calculation is possible! A solution for AC analysis of Ritz lines.
- Magnetic field analysis/electromagnetic wave analysis
- Contract Analysis
- Analysis Services
Introducing useful examples related to modeling in three-dimensional motor analysis.
- Magnetic field analysis/electromagnetic wave analysis
- Analysis Services
- PM motor
Improving the deterioration of convergence characteristics! Introducing a method for modeling with shell elements and performing magnetic field analysis.
- Magnetic field analysis/electromagnetic wave analysis
- Contract Analysis
- Analysis Services
Introduction to magnetic field analysis of a wireless power transfer system with varying positions between the transmitting and receiving coils using the slide method.
- Magnetic field analysis/electromagnetic wave analysis
- Contract Analysis
- Analysis Services
Features of EMSolution illustrated with a two-dimensional analysis of an induction motor!
- Magnetic field analysis/electromagnetic wave analysis
- Generators and transmission motors
- Analysis Services
Development of a method for evaluating AC losses in Litz wire using electromagnetic field analysis - Significantly reducing computation time and the burden of mesh generation.
- Contract Analysis
- Analysis Services
- Magnetic field analysis/electromagnetic wave analysis
Evaluation Method for AC Resistance of Ritz Line Coils
- Magnetic field analysis/electromagnetic wave analysis
- Analysis Services
- simulator
We will respond to the rationalization of design development, shortening of periods, performance improvement, and cost reduction.
- Analysis Services
- Contract Analysis
Prototype response: Utilizing CAE for investigating the causes of equipment malfunctions!
- Other analyses
- Analysis Services
Observation of the sensor chip surface, creating a cross-section through mechanical polishing in the mounted state, and conducting structural observation of the device!
- Analysis Services
- Analytical Equipment and Devices

Observation of tracking camera cross-section by mechanical grinding.
I would like to introduce "Cross-sectional observation of tracking camera using mechanical polishing." Regarding the structure of the tracking camera components, when viewed from above, the lens can be identified. Although it cannot be clearly seen in the X-ray image, the lens is incorporated into the convex part. Additionally, the cross-sectional structure is similar to that of an RGB sensor, featuring a back-illuminated CMOS structure. However, since color information is not necessary for the tracking camera, there is no color filter layer. A jagged uneven shape was observed on the surface of the photodiode.
Measure the change state with a 3D shape measuring device! Visually confirm the indented shape and amount due to pressure.
- Analysis Services
- Analytical Equipment and Devices

Observation of thermal deformation using a 3D shape measuring machine (VR-6200)
This is a measuring device that can non-contact measure surface shapes such as concavities, undulations, and surface roughness. We will introduce "heating deformation observation" using a 3D shape measuring machine. First, we acquire a 3D texture image at room temperature, and then we acquire a 3D texture image in the heated state. By overlaying the texture images before and after heating and checking the differential texture image and cross-sectional profile, it can be seen that the substrate in the heated state has higher ends and a lower center compared to the room temperature state.
By adding a special reagent to the sample and heating it, it becomes possible to detect substances that are usually difficult to detect!
- Analysis Services
- Contract Analysis

Chemical Analysis Concierge Service
We would like to introduce our "Chemical Analysis - Trust Us Service." When conducting component analysis of foreign substances or stains on products, it can be challenging to determine whether organic analysis or inorganic analysis is more suitable, and which specific analysis within organic or inorganic is the most appropriate. We provide a comprehensive service for customers who are struggling with the selection of analysis methods. Since each analysis device can measure different targets, it is necessary to choose a method that fits the purpose based on the information available.
We will suggest appropriate analysis methods based on the condition of polymer materials and samples!
- Contract Analysis
- Analysis Services
- Contract Analysis

Chemical Analysis Concierge Service
We would like to introduce our "Chemical Analysis - Trust Us Service." When conducting component analysis of foreign substances or stains on products, it can be challenging to determine whether organic analysis or inorganic analysis is more suitable, and which specific analysis within organic or inorganic is the most appropriate. We provide a comprehensive service for customers who are struggling with the selection of analysis methods. Since each analysis device can measure different targets, it is necessary to choose a method that fits the purpose based on the information available.
Distinguish and identify compounds with similar structures! You can obtain information such as the number of protons and structural characteristics.
- Contract Analysis
- Analysis Services
- Contract Analysis

NMR analysis of liquid crystal compounds
At Aites Co., Ltd., we conduct "NMR analysis of liquid crystal compounds." NMR is an analytical method that reveals the connections between atoms that make up a molecule, and it is used alongside mass spectrometry and infrared spectroscopy for determining the structure of compounds. In the downloadable materials, we highlight the 1H NMR, 13C NMR, and DEPT measurements of 4-butoxy-4'-cyanobiphenyl (CAS number 52709-87-2), which is used as a liquid crystal component, and introduce the information obtained from NMR. Please feel free to download and take a look.
It is possible to analyze resin materials and evaluate the characteristics that affect product performance!
- Contract Analysis
- Analysis Services
- Contract Analysis
For transparent materials such as glass and ITO! Measurement and evaluation of various transparent resins before and after UV exposure are also possible.
- Analysis Services
- Other contract services
- Contract measurement

Optical film light transmission characteristics
At Aites Co., Ltd., we conduct "optical film analysis." Optical films used in smartphones and other devices have various functions depending on their structure and materials. We measured the light transmittance of privacy protection films at different angles and combined cross-sectional observation with Raman analysis to investigate the mechanism of function manifestation. By investigating the transmittance characteristics of privacy protection films using angle-variable spectrophotometry, we were able to analyze the mechanism of function manifestation through cross-sectional observation and Raman analysis. At Aites, we provide consistent evaluation and analysis from material properties to the mechanisms of function manifestation.
Detect and analyze the absorption wavelengths of organic molecular groups (functional groups)!
- Contract Analysis
- Contract Analysis
- Analysis Services

Chemical Analysis Concierge Service
We would like to introduce our "Chemical Analysis - Trust Us Service." When conducting component analysis of foreign substances or stains on products, it can be challenging to determine whether organic analysis or inorganic analysis is more suitable, and which specific analysis within organic or inorganic is the most appropriate. We provide a comprehensive service for customers who are struggling with the selection of analysis methods. Since each analysis device can measure different targets, it is necessary to choose a method that fits the purpose based on the information available.
Depending on the panel size, it is possible to analyze using different ICP-AES/MS devices!
- Analysis Services

Chemical Analysis Concierge Service
We would like to introduce our "Chemical Analysis - Trust Us Service." When conducting component analysis of foreign substances or stains on products, it can be challenging to determine whether organic analysis or inorganic analysis is more suitable, and which specific analysis within organic or inorganic is the most appropriate. We provide a comprehensive service for customers who are struggling with the selection of analysis methods. Since each analysis device can measure different targets, it is necessary to choose a method that fits the purpose based on the information available.
Distinguish compounds with similar molecular structures through NMR analysis, elucidating the binding positions of side chains and substituents, as well as branching structures!
- Contract Analysis
- Analysis Services
- Contract Analysis

Chemical Analysis Concierge Service
We would like to introduce our "Chemical Analysis - Trust Us Service." When conducting component analysis of foreign substances or stains on products, it can be challenging to determine whether organic analysis or inorganic analysis is more suitable, and which specific analysis within organic or inorganic is the most appropriate. We provide a comprehensive service for customers who are struggling with the selection of analysis methods. Since each analysis device can measure different targets, it is necessary to choose a method that fits the purpose based on the information available.
We will introduce an analysis example confirming that the welded area has a large distribution of grain crystals.
- Analysis Services
- Contract Analysis

Example of analysis of compounds at the SAC solder and Ni pad interface.
We will introduce an example of the analysis of compounds formed at the interface between Sn-Ag-Cu solder and NiP pads. At the interface of NiP pads and Sn-Ag-Cu solder, compounds such as (Ni,Cu)3Sn4 and (Cu,Ni)6Sn5 grow, and surface analysis using EDX shows the distribution of Ni, Cu, and Sn within these compounds. The EBSD method is a technique that analyzes based on the crystallographic information of the sample. By combining it with elemental analysis using EDX, it is possible to estimate the composition, and in some cases, it may be possible to analyze using crystallographic data for Ni3Sn4 and Cu6Sn5 as substitutes.
It will lead to the determination of development direction and acceleration! We will respond with abundant technology, knowledge, and equipment.
- Analysis Services
- Other contract services

Chemical Analysis Concierge Service
We would like to introduce our "Chemical Analysis - Trust Us Service." When conducting component analysis of foreign substances or stains on products, it can be challenging to determine whether organic analysis or inorganic analysis is more suitable, and which specific analysis within organic or inorganic is the most appropriate. We provide a comprehensive service for customers who are struggling with the selection of analysis methods. Since each analysis device can measure different targets, it is necessary to choose a method that fits the purpose based on the information available.
Even with larger-sized implementation boards, resin embedding is possible without cutting before embedding! We will introduce cases with and without heat generation prevention treatment.
- Analysis Services
- Other contract services

About the curing temperature of epoxy resin free from hazardous substances.
We conducted measurements to reconfirm the temperature of heat generation during curing, following the change to a non-toxic epoxy resin. When using a large amount of resin, we apply heat generation prevention treatment for resin embedding. Without this treatment, the temperature can rise up to 138°C during curing. However, by applying the heat generation prevention treatment even with a large amount of resin, we were able to keep the heat generation during curing within 30°C.
The measured silicon wafer is single crystal! The IPF map, pole figure, and inverse pole figure resulted in relatively simple outcomes.
- Analytical Equipment and Devices
- Analysis Services

Example of analysis of compounds at the SAC solder and Ni pad interface.
We will introduce an example of the analysis of compounds formed at the interface between Sn-Ag-Cu solder and NiP pads. At the interface of NiP pads and Sn-Ag-Cu solder, compounds such as (Ni,Cu)3Sn4 and (Cu,Ni)6Sn5 grow, and surface analysis using EDX shows the distribution of Ni, Cu, and Sn within these compounds. The EBSD method is a technique that analyzes based on the crystallographic information of the sample. By combining it with elemental analysis using EDX, it is possible to estimate the composition, and in some cases, it may be possible to analyze using crystallographic data for Ni3Sn4 and Cu6Sn5 as substitutes.
It is possible to analyze with good sensitivity using thermal desorption GC-MS analysis! We propose methods tailored to the symptoms of issues and objectives.
- Other analyses
- Contract Analysis
- Analysis Services

Chemical Analysis Concierge Service
We would like to introduce our "Chemical Analysis - Trust Us Service." When conducting component analysis of foreign substances or stains on products, it can be challenging to determine whether organic analysis or inorganic analysis is more suitable, and which specific analysis within organic or inorganic is the most appropriate. We provide a comprehensive service for customers who are struggling with the selection of analysis methods. Since each analysis device can measure different targets, it is necessary to choose a method that fits the purpose based on the information available.
Mechanical grinding allows for a wide range of processing and observation! We will propose appropriate processing and observation methods or combinations.
- Analysis Services
- Other contract services

About the curing temperature of epoxy resin free from hazardous substances.
We conducted measurements to reconfirm the temperature of heat generation during curing, following the change to a non-toxic epoxy resin. When using a large amount of resin, we apply heat generation prevention treatment for resin embedding. Without this treatment, the temperature can rise up to 138°C during curing. However, by applying the heat generation prevention treatment even with a large amount of resin, we were able to keep the heat generation during curing within 30°C.
If any issues arise, detailed analysis will also be provided! A simplified analysis for customers considering the introduction of overseas LCDs.
- Analysis Services

Observation of Conductive Particle Shape in COG Implementation
We will introduce the observation of the shape of conductive particles in COG implementation. ICs and liquid crystal panels are implemented using the COG method with ACF (anisotropic conductive film). A resin ball is used as the core, and a metal layer (such as nickel or gold) for conductivity is deposited on its surface. During connection, the particles deform appropriately to electrically connect the IC and the panel. To confirm the degree of particle deformation and connection status, cross-sectional observations were conducted, revealing that the particle deformation was at a "medium" level, indicating an appropriate degree of deformation. By examining the deformation of conductive particles from both the planar and cross-sectional directions, we can explore the correlation with display defects. Please feel free to contact us for any inquiries regarding panel-related defects.