Why is silica likely to remain in pure water systems? This will explain its properties as a weak acid, its impact on boilers, how to choose resins, and how to measure it.
Silica, in the context of pure water and boiler water, refers to the silicic acid that is dissolved in water. The silica mentioned in discussions about drinking water is in a different context, and here we will look at it as a component that we want to reduce in order to protect equipment. ■ Why is it likely to remain with ion exchange? Silicic acid is a very weak acid with a low degree of dissociation. The pKa of silicic acid is about 9.5, and near neutral pH, it is mostly not ionized. Because the proportion of ionized silicic acid is low, it is less likely to be exchanged for resin compared to components like chlorides. ■ Weakly basic resins are insufficient Among anion exchange resins, weakly basic resins cannot exchange weak acids like silicic acid or carbonic acid. To reduce silica, strong basic anion exchange resins are necessary. There are Type I and Type II strong basic resins, and Type I is chosen for applications where low silica levels are desired. ■ What components leak out first? As the exchange capacity of the resin approaches its end, silica is one of the components that leaks into the treated water at an early stage. Therefore, in addition to monitoring resistivity (the difficulty of conducting electricity), there is a method of using silica concentration as a guideline for regeneration. Please feel free to consult with us first.
Inquire About This Product
basic information
■What problems arise with boilers? Silica is a component that creates difficult-to-remove deposits inside boilers. In high-pressure boilers, silica tends to dissolve in steam and is carried away more easily, with its solubility increasing as pressure and temperature rise. ■What happens when it attaches to turbines? Silica carried by steam adheres to turbine blades and other components, leading to decreased efficiency and potential failures. Deposits that accumulate in low-pressure areas are difficult to dissolve in water and require considerable effort to remove. In high-pressure systems, maintaining low silica levels in the feedwater is emphasized. ■Basic countermeasures 1. Resin: Use strong alkaline anion exchange resin. 2. Regeneration: Restore exchange capacity with an alkaline regenerant. 3. Monitoring: Measure silica in treated water and regenerate when levels begin to rise. 4. Pretreatment: Combine with other methods such as RO membranes. ■When to switch to regeneration? Strong alkaline anion exchange resin is regenerated with a sodium hydroxide solution. Silica begins to leak quickly at the end of its exchange capacity, so the point at which silica levels in treated water start to rise serves as a signal to switch to regeneration.
Price range
Delivery Time
Applications/Examples of results
■ How to Measure Silica? A commonly used method involves adding molybdate to color the solution and measuring its intensity. When silica reacts with molybdate, a yellow compound is formed, and the yellow color is measured in water with a higher concentration. In trace amounts, the solution is further reduced to a blue color (molybdenum blue) to increase sensitivity for measurement. ■ The Term "Reactive Silica" Silica that reacts with molybdate is referred to as "reactive silica," and measurement results may be indicated by this name. Since the range represented can differ depending on the measurement method, it is important to ensure that the same method and units are used when comparing values. There are also methods that include steps to add chemicals that suppress the influence of interfering components. ■ Differentiating Monitoring Methods There are methods that involve placing a continuous silica meter at the outlet of the device and methods that involve sampling at set intervals for measurement. The required values and monitoring frequency change depending on the boiler pressure and the application of pure water. If you are concerned about silica in your applications and want to review which resin you are using, please feel free to contact us. We welcome your inquiries.
catalog(3)
Download All CatalogsCompany information
Since our founding, we have continued to provide flexible services with the motto of accurately supplying a diverse range of products that respond to changes in the times and the diversification of consumer needs, tailored to various applications and requirements. With the corporate slogan "Chemical Engineering Partner," we, as a group of experts in chemical technology, actively discover ideas to solve our customers' problems from advanced technologies both domestically and internationally, and propose them.


![What is RO membrane (reverse osmosis membrane)? Mechanism and applications [Basic knowledge]](https://image.mono.ipros.com/public/product/image/2094936/IPROS3864637480662902513.jpg?w=280&h=280)
![What are PFAS? Regulations and removal methods in water supply and drainage [Basic Knowledge]](https://image.mono.ipros.com/public/product/image/2094936/IPROS11524899789117550081.jpg?w=280&h=280)
![What is a pure water system? Key points of the 2-bed 3-tower mechanism and operation [Basic Knowledge]](https://image.mono.ipros.com/public/product/image/2094936/IPROS5440712044023579082.jpg?w=280&h=280)
![What is MF membrane (microfiltration membrane)? Differentiation from UF membrane and sand filtration [Basic Knowledge]](https://image.mono.ipros.com/public/product/image/2094936/IPROS995478300726706091.jpg?w=280&h=280)