Magnetic Component Measurement System Model 1810
An automatic measurement system developed to measure the relationship between the power consumption and temperature of magnetic components.
The 1810 is a system developed to measure the relationship between power consumption and temperature. This system is equipped with both DC and AC power supplies, allowing for the measurement of copper losses and iron losses in magnetic components. Copper losses and iron losses are factors that cause temperature rises in magnetic components, and if the temperature is too high, it can affect the inductance of the magnetic components while significantly increasing their power consumption. In other words, components with high copper and iron losses become products with a high risk of electrical anomalies. By having both DC and AC power supplies, it can be widely used for measuring magnetic components, measuring internal temperatures with thermometers, and measuring power losses in magnetic components with high-frequency power meters, covering everything from the development to the analysis of magnetic component materials. Furthermore, it is also possible to measure electrical responses occurring under different electrical conditions with components of the same inductance. When combined with software, it can record temperature changes and power consumption of magnetic components, allowing for easy analysis and evaluation of measurement results. The 1810 is the optimal measurement system for analyzing magnetic components.
- Company:クロマジャパン
- Price:Other