[Example] Custom nozzle with a small flow rate of 500 mL/min
Manufactured a 500mL/min nozzle! Adjusted to increase vacuum level, resulting in an increase in bubble generation.
We would like to introduce a case study using the '500mL/min small custom nozzle' from OK Engineering Co., Ltd. In July 2011, at a water pressure of 0.15MPa, the discharge rate was 410mL/min, and the vacuum level was approximately -0.03MPa under normal settings. A 500mL/min nozzle was manufactured, and adjustments were made to increase the vacuum level at the nozzle agitation section to -0.09MPa when the water pressure was 0.25MPa, resulting in a slight increase in bubble generation. Currently, we are ensuring that the vacuum level of the nozzle exceeds -0.05MPa at a water pressure of 0.15MPa. [Case Summary] <July 2011> ■ A 500mL/min nozzle was manufactured. ■ Since the generation amount is low, it is necessary to increase the vacuum level if required. ■ Adjusted to increase the vacuum level to -0.09MPa at a water pressure of 0.25MPa. ■ There was a slight increase in bubble generation. *For more detailed information about the case, please refer to the related links. For further inquiries, feel free to contact us.
- Company:OKエンジニアリング
- Price:Other