91~135 item / All 568 items
Displayed results
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationContact this company
Contact Us Online91~135 item / All 568 items
Bond Elut Carbon is a solid-phase extraction mini-column that uses graphite carbon black as the packing material. Due to the layered structure of carbon atoms, it exhibits strong retention for compounds with planar structures, such as chlorophyll. Because of these characteristics, it is suitable for the removal of pigments from food extracts and the concentration of compounds (pesticides) with aromatic rings in environmental water. Additionally, since this graphite carbon black is non-porous, it allows for easy flow and elution, enabling high recovery rates for various compounds. *For more details, please refer to the PDF document or feel free to contact us.*
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe Mega Bond Elut Flash column provides high performance and high productivity for the flash purification of organic compounds in both aqueous and hydrophobic solutions. The pre-packed disposable column offers even greater convenience compared to glass columns, which require cleaning, drying, and re-packing each time they are used. Due to the compatibility with automated flash systems, high throughput is ensured even when high reproducibility is required. *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationEnvirElut PAH is a pure high-capacity sorbent suitable for the extraction of polycyclic aromatic hydrocarbons (PAH) from aqueous matrices. Each lot of EnvirElut PAH undergoes rigorous testing for residual environmental contaminants from water samples before being shipped as a product. Next, the sorbent of EnvirElut PAH is packed into Bond Elut cartridges suitable for PAH analysis. *For more details, please refer to the PDF document or feel free to contact us.*
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe same Bondesil packing material that is filled in Bond Elut cartridges can be provided in bulk for large-scale purification or custom cartridge creation. The chemically bonded Bondesil packing material was specifically designed for separations that require selectivity, such as the following. *For more details, please refer to the PDF document or feel free to contact us.*
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationA wide variety of empty containers are used to increase the sample processing capacity of Bond Elut cartridges. You can also fill them with your preferred packing material to create custom-made solid-phase extraction cartridges. Empty cartridges with frits include a polypropylene container and two polypropylene frits. This setup is also ideal for simple filtration. Additional frits can be purchased separately for filling custom-made packing materials. *For more details, please refer to the PDF materials or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationIf the sample volume exceeds the capacity of the Bond Elut cartridge container, you can use the Bond Elut adapter to attach a larger container to the top of the cartridge, thereby increasing the volume capacity. The Bond Elut adapter fits onto the top of the Bond Elut cartridge and has a luer fitting connection that allows another cartridge tip to fit. To select the appropriate adapter, please choose the one specified for the Bond Elut cartridge. The adapter fits correctly on the top of the cartridge container. All Bond Elut cartridges and empty SPE cartridges come with standard luer tips that are compatible with these adapters. *For more details, please refer to the PDF materials or feel free to contact us.*
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationAgilent's gas clean filter system improves gas quality and maximizes productivity. Clean gas reduces the risk of column damage, loss of sensitivity, and equipment downtime. Contaminants present in the gas can have a significant impact on analysis. The presence of oxygen, hydrocarbons, and moisture in the gas can lead to decreased sensitivity and analytical accuracy in GC analysis, and can also cause damage to the column. Impurities activate the glass wool in the liner and accelerate the degradation of the septum. As a result, high background signals and ghost peaks may occur, leading to time-consuming troubleshooting. *For more details, please refer to the PDF document or feel free to contact us.*
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationAgilent offers a wide range of HPLC syringes for Shimadzu autosamplers. You can choose from various syringe styles and capacities, enabling accurate and effective sampling. Agilent's syringes meet a variety of criteria regarding shape, compatibility, and functionality, from large and small capacity autosampler syringes to syringes for pump priming, supporting HPLC systems. *For more details, please refer to the PDF document or feel free to contact us.*
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationAgilent offers a wide range of HPLC syringes for Dionex auto samplers. You can choose from various syringe styles and capacities, enabling accurate and effective sampling. Agilent syringes meet various standards in terms of shape, compatibility, and functionality, from large and small volume auto sampler syringes to syringes for pump priming, supporting HPLC systems. The syringe tip at the end of the syringe barrel functions as an interface between the syringe and the compatible connection (such as a needle). To accommodate a wide range of applications, the tip is available in various needle and connection configurations. *For more details, please refer to the PDF document or feel free to contact us.*
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationAgilent offers a wide range of HPLC syringes for Waters auto samplers. You can choose from various syringe styles and capacities, ensuring accurate and effective sampling. Agilent syringes meet various standards in terms of shape, compatibility, and functionality, supporting HPLC systems, from large and small capacity auto sampler syringes to syringes for pump priming. The syringe tip at the end of the syringe barrel functions as the interface between the syringe and the compatible connection (such as a needle). *For more details, please refer to the PDF document or feel free to contact us.*
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe color-coded barrels make it easy to identify the capacity of the syringes, adding vibrancy to the lab. When performing tasks such as dilution, extraction, expansion, or sample pretreatment manually, using Agilent's manual syringes can simplify operations at every stage of sample processing and improve productivity. The glass barrels are color-coded by capacity (from 0.5μL to 50mL), allowing for quick and easy differentiation of syringes. *For more details, please refer to the PDF document or feel free to contact us.*
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationAgilent offers two main product lines for gas chromatography (GC) syringes: the Agilent Blue Line and the Gold Standard. Agilent's premium Blue Line GC autosampler syringes are specially designed to be compatible with the Agilent 7693A Automatic Liquid Sampler (ALS). The plunger fits precisely into the stroke mechanism of the 7693A ALS, improving injection accuracy and extending the lifespan of the plunger. *For more details, please refer to the PDF document or feel free to contact us.*
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationAgilent offers a variety of syringes to meet different needs, allowing for accurate and effective sample delivery from CTC autosamplers. We provide a wide range of syringes for liquid injection, headspace injection, and for CombiPAL and PAL3 autosamplers. By using Agilent's syringe selection tool, you can find the syringe that is suitable for your application. If you need assistance in creating custom scripts for the PAL3 autosampler system, please take advantage of our script creation service. *For more details, please refer to the PDF materials or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationA smart syringe compatible with the PAL3 auto-sampler has been introduced. Each smart syringe is equipped with a dedicated read/write chip, allowing for tracking of important parameters such as the number of injections made with a specific syringe and the maximum temperature used with the syringe. Furthermore, the PAL3 device automatically recognizes and uploads these parameters, enabling efficient and detailed tracking. Agilent offers a variety of syringes to meet different needs, ensuring accurate and effective sample delivery from the CTC auto-sampler. *For more details, please refer to the PDF document or feel free to contact us.*
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe Bond Elut Lipid Extraction SPE 1mL cartridge and 2mL 96-well plate have highly selective and efficient lipid extraction capabilities, making them useful for lipid analysis, lipid profiling, and lipidomics workflows. These SPE products, which utilize a unique EMR-Lipid packing technology, combine size exclusion and hydrophobic interactions to selectively capture and isolate lipids, allowing for efficient elution from the cartridge or well plate. There is a washing step between sample loading and lipid elution, which removes other matrix interfering substances through the washing process. *For more details, please refer to the PDF document or feel free to contact us.*
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationSample leak adsorbents can be purchased in bulk, allowing you to freely choose reservoirs and frits to customize SPE cartridges or perform "flash" chromatography. *For more details, please refer to the PDF materials or feel free to contact us.*
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationChem Elut S products provide highly reproducible solid-liquid extraction (SLE) results that accommodate high data quality and a large number of samples. Consistent pore and particle sizes ensure batch-to-batch reproducibility and uniform flow. Additionally, since stirring is not required, the formation of emulsions can be avoided. Compared to liquid-liquid extraction, Chem Elut S exhibits less variability between analysts, removes more matrix, and minimizes the amount of extraction solvent used. As a result, the concentration of the target analytes increases. *For more details, please refer to the PDF document or feel free to contact us.*
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationBond Elut Carbon S, Bond Elut Carbon S/NH2, and Bond Elut Carbon S/PSA cartridges are optimized for the adsorption of pigments from organic residues in food, fruits, vegetables, and wastewater. Agilent Carbon S adsorbent is an advanced hybrid carbon material with optimized carbon content and pore structure, capable of improving the recovery rates and RSD of planar pesticides compared to GCB. Carbon S/NH2 and Carbon S/PSA each contain NH2 and PSA, respectively, enhancing the removal of polar compounds. *For more details, please refer to the PDF document or feel free to contact us.*
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationBond Elut Plexa PAX sets a new performance standard for the purification and reproducibility of polar and non-polar acidic compounds. Existing polymer-based anion exchange solid-phase extraction columns had significant variations in ion exchange capacity between lots, leading to low reproducibility and data accuracy. The particles of Bond Elut Plexa PAX utilize a unique manufacturing method that allows for high-level control of the capacity of the anion exchange resin, ensuring stable and more robust performance over an extended period. *For more details, please refer to the PDF document or feel free to contact us.*
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationLeak detectors are important devices in various facilities that manufacture or use gases. Laboratories that conduct analyses such as chromatography, spectroscopic analysis, and mass spectrometry using expensive high-purity gases or hazardous gases routinely monitor gases with leak detectors. The Agilent CrossLab CS (Cartridge System) leak detector detects leaks of various gases within laboratories and facilities, ensuring leak-free connections. The new CrossLab CS leak detector features a groundbreaking cartridge design that allows for both leak detection and flow measurement in a single device. This enables both leak detection and flow measurement to be performed with one handheld system, contributing to improved efficiency in the laboratory. *For more details, please refer to the PDF document or feel free to contact us.*
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe new ADM flow meter does not have the recalibration concerns associated with the common ADM 1000. It serves as an effective tool for verifying gas flow and can also assist in troubleshooting detectors. The ADM flow meter is well-suited for measuring the flow of mixed gases. Since it measures gas by volume, there is no need to select the type of gas. Additionally, it features a removable calibration cartridge, making maintenance easy. Recalibration can be completed simply by replacing the cartridge once a year in the lab, allowing you to maintain compliance. There is no need to return the flow meter itself. *For more details, please refer to the PDF document or feel free to contact us.*
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationAgilent offers the Smart SPME Arrow compatible with all models of the PAL3 series, including the PAL3 Series II smart devices. The SPME Arrow can be used for headspace analysis and can also concentrate analytes through immersion. The sensitivity of the Agilent Smart SPME Arrow is up to 10 times that of SPME fibers. Each Smart SPME Arrow is equipped with a dedicated smart chip that stores information such as specific Arrow parameters, range, and usage history. The Agilent Smart SPME Arrow is color-coded to easily distinguish between different coating phases and thicknesses. Whether you are using the SPME Arrow for the first time or switching to smart technology, you can use the Agilent Smart SPME Arrow with confidence, as it maintains top-quality performance. *For more details, please refer to the PDF materials or feel free to contact us.*
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationAgilent offers smart SPME fibers compatible with all models of the PAL3 series, including the PAL3 Series II smart devices. Each smart SPME fiber is equipped with a dedicated smart chip that stores information such as specific fiber parameters, range, and usage history. Agilent smart SPME fibers are color-coded to easily distinguish between different coating phases and thicknesses. Whether you are using SPME for the first time or switching to smart technology, you can use Agilent smart SPME fibers with confidence, as they maintain top-quality performance. *For more details, please refer to the PDF materials or feel free to contact us.*
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe following accessories are useful for SPME sample preparation. Please choose the accessories that suit your application needs. *For more details, please refer to the PDF document or feel free to contact us.*
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe Agilent SPME Arrow is an advanced improved version of the SPME fiber. It can be used for headspace analysis and can also concentrate components on the Arrow by immersing it in a liquid. The SPME Arrow is compatible with various chemical coatings and has a sensitivity that is ten times greater than that of SPME fibers. *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationSample filtration prior to HPLC, UHPLC, LC/MS, GC, and GC/MS analysis is essential to achieve optimal system performance. The Agilent Captiva Premium Syringe Filters accelerate this process more than ever, thanks to industry-leading flow rates and loading capacity. Additionally, Agilent conducts more LC/MS tests with syringe filters than other manufacturers to ensure that there are no extracts from the filters. All Agilent Captiva Premium Syringe Filters come with HPLC or LC/MS certification. You can choose from a variety of membrane types and pore sizes to suit your needs. - Agilent Captiva Premium Syringe Filter Specifications/Price List/Details - Agilent Captiva Premium Syringe Filter Selection Guide - Premium Syringe Filter Chemical Compatibility Chart - Instructions for Use - Captiva Syringe Filter *For more details, please refer to the PDF materials or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationBy enhancing the level of sample filtration, better results can be obtained in a shorter time. Sample filtration in HPLC, UHPLC, and LC/MS is essential for achieving optimal system performance. The Agilent Captiva Econofilter is a cost-effective choice suitable for busy labs handling many samples. You can choose from various membrane types and pore sizes to meet your needs. - Econofilter price list/details - Econofilter chemical compatibility chart - Instructions for use - Captiva syringe filter *For more details, please refer to the PDF materials or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationCaptiva EMR-Lipid performs highly selective and efficient lipid/matrix removal without losing target compounds. The new EMR-Lipid removes lipids by combining size exclusion and hydrophobic interactions. Effective lipid removal minimizes ion suppression of target compounds, significantly improving the reliability and robustness of the analysis. The 96-well plate and 1mL cartridge format enable solvent-first protein precipitation within the well. This simplifies sample preparation and allows for easy flow through improved filter design using vacuum or positive pressure. The 3mL and 6mL cartridges are particularly suitable for lipid removal from food samples. Please note that this frit does not have a Non-Drip structure. *For more details, please refer to the PDF document or feel free to contact us.*
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationAgilent offers a dispersive SPE kit designed to remove lipids from lipid-rich samples. This kit can be used with any sample type. The dispersive SPE kit allows for the removal of lipids from the sample while retaining the analytes of interest. Excess moisture is removed in the final dehydration step, improving the accuracy of analyte separation. This dispersive kit contains 1g of pre-weighed adsorbent in a 15mL centrifuge tube, easily accommodating the supernatant volume specified in current AOAC and EN methods. Bond Elut QuEChERS Enhanced Matrix Removal Dispersive Kit (5982-1010) Bond Elut QuEChERS Enhanced Matrix Removal Dehydration Kit (5982-0101) Please refer to the recommended protocol for Enhanced Matrix Removal-Lipid. *For more details, please refer to the PDF document or feel free to contact us.*
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationSolid phase extraction (SPE), supported liquid-liquid extraction (SLE), and filtration (protein removal) using cartridges and 96-well plates under pressure have many advantages over conventional vacuum processing. In a typical vacuum manifold, liquid is drawn from the bottom of the cartridge or 96-well plate. When a fast-flowing cartridge empties first, it creates a vacuum state as it becomes the path of least resistance, resulting in a slower flow in the remaining cartridges. This uneven state can lead to variations in processing time and may compromise the reproducibility of results. As an alternative for processing such samples, the Agilent pressure manifold for 48 SPE cartridges (PPM-48) is excellent. The PPM-48 is equipped with unique flow-limiting ports that maintain consistent gas flow across all ports, even if some ports are unused or empty. This consistency ensures reproducibility between columns and cartridges, regardless of the content volume in the cartridges or wells. *For more details, please refer to the PDF document.*
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationSolid-phase extraction (SPE), supported liquid extraction (SLE), and filtration (protein removal) using cartridge and 96-well plate pressurization offer many advantages over conventional vacuum processing. In a typical vacuum manifold, liquid is drawn from the bottom of the cartridge or 96-well plate. When a fast-flowing cartridge empties first, it becomes the path of least resistance, resulting in a vacuum state, which slows down the flow in the remaining cartridges. This uneven condition can lead to variability in processing time and may compromise the reproducibility of results. As an alternative for processing such samples, the Agilent pressurized manifold for 96-well plates (PPM-96) is excellent. The PPM-96 is equipped with unique flow-limiting ports that maintain consistent gas flow across all ports, even if some ports are unused or empty. This consistency ensures reproducibility between columns and cartridges, regardless of the contents of the cartridges or wells. *For more details, please refer to the PDF document.*
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationWhen ordering SPME fibers, please note that the fiber kit contains only the fibers. For your initial order, you will need to separately order a fiber holder that meets your needs. With proper care and careful handling, there are applications where SPME fibers can be used multiple times. The color coding or notched hubs of each fiber indicate the type of coating on the fibers. *For more details, please refer to the PDF materials or feel free to contact us.*
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe SPME fiber kit includes three types of fibers. The fiber coating thickness (df) is indicated in micrometers (μm). If the kit contains multiple types of coating phases, the fiber coatings are listed in the same order as the phases in the "Overview." *For more details, please refer to the PDF materials or feel free to contact us.*
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe Agilent high-purity, porous inert silica gel column, Chem Elut, is used for liquid-liquid extraction in the solid phase. The operation method is simple and consists of three steps: (1) add the sample aqueous solution, (2) let it sit for about 5 minutes, (3) pass the organic solvent through. *For more details, please refer to the PDF document or feel free to contact us.*
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationQuEChERS (pronounced "catchers") is an acronym that represents the features of this food sample preparation method: Quick, Easy, Cheap, Effective, Rugged, and Safe. With just a few simple steps, food samples can be prepared for multi-class multi-residue pesticide analysis. Agilent QuEChERS includes packaged extraction kits and dispersed SPE kits configured for specific food types or screening protocols. The QuEChERS SOP can be helpful as a starting point. *For more details, please refer to the PDF materials or feel free to contact us.*
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe Captiva filter plates, 96 well collection plates, and SPEC 96 well plates can all use vacuum colors, which are tools that allow the Captiva or SPEC plates to be directly coupled to Agilent's collection plates. The unique design of the Captiva color creates a vacuum seal between the filter plate and the collection plate. Specific outlets are positioned at intervals within each well, preventing secondary contamination of the samples. *For more details, please refer to the PDF document or feel free to contact us.*
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationTo prevent clogging of HPLC columns, a simple and versatile filtration process is essential. Captiva 0.2µm and 0.45µm filter plates are suitable for removing precipitated protein samples as a pre-treatment for LC/MS analysis. Captiva 10µm and 20µm glass fiber filter plates are designed to clarify samples containing a lot of particles, such as fresh frozen plasma and liver cells, thereby preventing issues with sample transfer caused by clogging of pipette tips. They are ideal for use with automated systems and Duo Seal 96 well seals. *For more details, please refer to the PDF materials or feel free to contact us.*
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe "Captiva96 Well Collection Plate" is specially designed to be used with the Captiva filter plate, SPEC SPE 96 well plate, and Bond Elut 96 well plate. With a capacity of 1mL, it ensures that the necessary volume is secured to recover all filtered or eluted substances. The "Captiva96 Well Silicone Cover" is easy to handle and can completely seal the plate, preventing sample loss or contamination due to leakage and evaporation. The silicone is specially designed to accommodate 96 well auto injectors, making penetration and removal easy while the cover is attached. *For more details, please refer to the PDF materials or feel free to contact us.*
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationCaptiva ND is designed to quickly and reproducibly remove proteins present in well plates. The Captiva ND plate, which uses a unique non-drip (ND) membrane, enables the removal of proteins using a solvent first method with methanol or acetonitrile. Captiva's unique dual filter design allows for fast and consistent flow, preventing filter clogging and achieving excellent filter recovery rates. *For more details, please refer to the PDF document or feel free to contact us.*
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationCaptiva filter vials are useful for sample filtration prior to LC and GC analysis. If you only need to filter the amount of sample contained in the vial for analysis, you can filter samples quickly, economically, and in an environmentally friendly manner compared to alternative methods that combine syringe filters, syringes, autosampler vials, septa, and caps. *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration0.2µm and 0.45µm filters are suitable for removing precipitated protein samples as a pre-treatment for LC/MS analysis. The Captiva 10µm glass fiber filter is designed to purify samples containing a lot of particles, such as fresh frozen plasma, thereby preventing issues with sample delivery caused by pipette tip clogging. The 3mL Non-Drip (ND) filter with a pore size of 0.2μm can be used with either methanol or acetonitrile and is designed to accommodate workflows using a vacuum manifold. By using these fast and easy-to-use single-sample cartridges, you can effectively remove precipitated proteins and particles. The ND lipid filter can also remove phospholipids from the sample, which can cause ion suppression prior to LC-MS. Using these dual filters allows for consistent flow and helps avoid clogging due to the sample. *For more details, please refer to the PDF document or feel free to contact us.*
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationIn biological samples, phospholipids, like proteins, can cause ionization suppression. In standard protein removal procedures, phospholipids present in plasma remain in the sample as interfering substances. However, by processing with "Captiva ND Lipids," both proteins and phospholipids can be removed simultaneously. This reduces ionization suppression caused by proteins while also minimizing ionization suppression due to phospholipids, allowing for more accurate results. If phospholipids cannot be completely removed, the ionization suppression effect becomes very pronounced. Using this product, you can obtain a much clearer extract compared to standard protein removal procedures. Even in ESI, one of the ionization methods for mass spectrometers, the ionization suppression effect is minimized. *For more details, please refer to the PDF document or feel free to contact us.*
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationLet's test your knowledge of USP<1058>, Analytical Instrument Qualification (AIQ), and compliance with computerized system validation. Do you have what it takes to become a CrossLab Compliance Champion? You can test your compliance knowledge with an online compliance knowledge check.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationMaintenance of lab equipment is a very important task for continuing to execute a smooth and effective workflow. The issue is whether to outsource the maintenance of the equipment or to handle it in-house. It may seem that self-maintaining the equipment could reduce costs. At first glance, this seems reasonable. Is there any reason to outsource tasks that can be handled in-house? However, there are many hidden costs associated with self-maintenance of equipment, and it is necessary to recognize them. Once the hidden costs become apparent, you may want to reconsider.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationAgilent has deep insights and extensive experience in PFAS analysis methods in water and environmental samples as a leader in the environmental analysis market for over 40 years. We support a comprehensive PFAS analysis workflow, from sample preparation to screening, quantification, and reporting.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration