List of Contract Services products
- classification:Contract Services
1711~1725 item / All 4772 items
Achieves high collection efficiency through electrostatic methods. Offers a wide range of products from large to small sizes. Also compatible with water-soluble oil mist.
- air conditioning
Introducing a new device! We present an analytical method aimed at the qualitative and quantitative analysis of components contained in samples.
- Analytical Equipment and Devices
- Contract Analysis
Chemical Analysis Concierge Service
We would like to introduce our "Chemical Analysis - Trust Us Service." When conducting component analysis of foreign substances or stains on products, it can be challenging to determine whether organic analysis or inorganic analysis is more suitable, and which specific analysis within organic or inorganic is the most appropriate. We provide a comprehensive service for customers who are struggling with the selection of analysis methods. Since each analysis device can measure different targets, it is necessary to choose a method that fits the purpose based on the information available.
Two high-power constant temperature and humidity chambers have been introduced! Ideal for temperature cycle tests and temperature and humidity cycle tests for automotive parts and more.
- Contract measurement
- Contract Analysis
- Contract Inspection
Rubber heat aging test
Our company conducts "rubber thermal aging tests" that help evaluate the properties of materials in actual usage environments. Using a method compliant with JIS K6257 (Method for determining thermal aging characteristics of vulcanized rubber and thermoplastic rubber), rubber test pieces are suspended in a gear oven to create specimens with varying heat treatment times. Additionally, tensile tests are performed on heated natural rubber (NR) to investigate changes in mechanical properties, while hardness is measured simultaneously. Changes in the characteristics of the rubber are also examined, confirming that rubber elasticity is lost and the material becomes harder with heating.
Numerous examples of "BGA solder crack analysis," "surface mount LEDs," and "chip resistor observation" using X-ray fluoroscopy and angled CT observation are included!
- X-ray inspection equipment
- Contract Inspection
- Contract Analysis
We offer a variety of measurement modes, including double cantilever beam bending and three-point bending with free support!
- Contract measurement
- Contract Analysis
- Weight related measuring instruments
Chemical Analysis Concierge Service
We would like to introduce our "Chemical Analysis - Trust Us Service." When conducting component analysis of foreign substances or stains on products, it can be challenging to determine whether organic analysis or inorganic analysis is more suitable, and which specific analysis within organic or inorganic is the most appropriate. We provide a comprehensive service for customers who are struggling with the selection of analysis methods. Since each analysis device can measure different targets, it is necessary to choose a method that fits the purpose based on the information available.
Observe the degree of endothermic/exothermic reaction of the sample! The temperature range is possible from -90°C to 550°C.
- Contract measurement
- Contract Analysis
Chemical Analysis Concierge Service
We would like to introduce our "Chemical Analysis - Trust Us Service." When conducting component analysis of foreign substances or stains on products, it can be challenging to determine whether organic analysis or inorganic analysis is more suitable, and which specific analysis within organic or inorganic is the most appropriate. We provide a comprehensive service for customers who are struggling with the selection of analysis methods. Since each analysis device can measure different targets, it is necessary to choose a method that fits the purpose based on the information available.
The analysis sensitivity of TOF-SIMS is high at the ppm level, making it effective for analyzing trace contamination!
- Contract Analysis
- Contract Inspection
- Contract measurement
Chemical Analysis Concierge Service
We would like to introduce our "Chemical Analysis - Trust Us Service." When conducting component analysis of foreign substances or stains on products, it can be challenging to determine whether organic analysis or inorganic analysis is more suitable, and which specific analysis within organic or inorganic is the most appropriate. We provide a comprehensive service for customers who are struggling with the selection of analysis methods. Since each analysis device can measure different targets, it is necessary to choose a method that fits the purpose based on the information available.
High-resolution imaging with a micro probe! Achieving nano-level structural analysis.
- Contract Analysis
- Contract measurement
- Other microscopes
Depth-direction measurements using Raman spectroscopy! Material analysis of each layer is possible from the surface of multilayer films.
- Spectroscopic Analysis Equipment
- Analytical Equipment and Devices
- Contract Analysis
Cryogenic ion milling cross-section processing example (rubber products)
We will introduce a case where cross-sections were created and observed by method regarding the adhesive parts of the tires of pull-back cars. When conducting SEM observations of the created cross-sections, fillers present inside the rubber were confirmed. It was found that the dispersion state of the fillers and the condition of the adhesive interface were not clear with fracture by liquid nitrogen or mechanical polishing. In contrast, the cross-sections created by cryo ion milling allow for clear observation of the dispersion state of the fillers contained within the rubber and the condition of the adhesive interface with the plastic substrate.
Applicable to change observation, with support for additional analysis! We evaluate the subject in a time series and non-destructive manner.
- Contract Inspection
- Testing Equipment and Devices
- Other inspection equipment and devices
Observation of substrate deformation using a 3D shape measuring device (VR-6200)
I would like to introduce "Observation of Substrate Deformation Using a 3D Shape Measuring Machine." By applying pressure to the PCB substrate, referencing bending tests of plastics and PCB substrates, the change in state is measured using a 3D shape measuring machine (VR-6200). Since the measurement results can be confirmed with a color palette and line profile, it is possible to visually verify the shape and amount of deformation caused by the applied pressure.
Achieve high processing precision and a wide processing area! Machining is also possible while reducing damage with cooling functions.
- Contract Inspection
- Processing Contract
Cryogenic ion milling cross-section processing example (rubber products)
We will introduce a case where cross-sections were created and observed by method regarding the adhesive parts of the tires of pull-back cars. When conducting SEM observations of the created cross-sections, fillers present inside the rubber were confirmed. It was found that the dispersion state of the fillers and the condition of the adhesive interface were not clear with fracture by liquid nitrogen or mechanical polishing. In contrast, the cross-sections created by cryo ion milling allow for clear observation of the dispersion state of the fillers contained within the rubber and the condition of the adhesive interface with the plastic substrate.
You can closely observe the solder joint condition of electronic components on the implementation board and the internal structure of the components!
- Other contract services
- Contract Inspection
Confirmation of chiplet package structure by mechanical polishing.
Regarding the chip mounted on the main circuit board of the VR goggles manufactured by Company A, upon visual observation, it was inferred that it has a chiplet structure with multiple chips integrated. To examine the structure in more detail, we created a cross-section using X-ray CT observation and mechanical polishing, and we will introduce the structural confirmation results. *For more details, please download the PDF or feel free to contact us.*
Pre-processing of SiC devices → Identification of leakage points → Physical analysis/component analysis handled seamlessly!
- Analysis Services
- Contract Analysis
Announcement of the introduction of Talos F200E
Our company will introduce the FEI "Talos F200E" transmission electron microscope system. Compared to conventional models, the resolution for TEM and STEM has improved, and performance has been significantly enhanced, allowing for EDS analysis with four detectors. Additionally, it is equipped with features such as drift-corrected frame integration (DCFI), which accumulates multiple frames while correcting for drift.
Even with SiC power devices, we can provide consistent support for cross-section preparation of specific areas, observation of diffusion layer shapes, as well as wiring structure and crystal structure...
- Analysis Services
- Contract Analysis
Check the quality status of LCD components and products! We will analyze the structures of the LCD panels using our analytical methods and expertise!
- Analysis Services
- Contract Analysis
Observation of Conductive Particle Shape in COG Implementation
We will introduce the observation of the shape of conductive particles in COG implementation. ICs and liquid crystal panels are implemented using the COG method with ACF (anisotropic conductive film). A resin ball is used as the core, and a metal layer (such as nickel or gold) for conductivity is deposited on its surface. During connection, the particles deform appropriately to electrically connect the IC and the panel. To confirm the degree of particle deformation and connection status, cross-sectional observations were conducted, revealing that the particle deformation was at a "medium" level, indicating an appropriate degree of deformation. By examining the deformation of conductive particles from both the planar and cross-sectional directions, we can explore the correlation with display defects. Please feel free to contact us for any inquiries regarding panel-related defects.
We will handle everything from the evaluation of the diffusion layer to physical analysis/chemical analysis regarding the malfunctioning part!
- Analysis Services
- Contract Analysis
- Semiconductor inspection/test equipment
Announcement of the introduction of Talos F200E
Our company will introduce the FEI "Talos F200E" transmission electron microscope system. Compared to conventional models, the resolution for TEM and STEM has improved, and performance has been significantly enhanced, allowing for EDS analysis with four detectors. Additionally, it is equipped with features such as drift-corrected frame integration (DCFI), which accumulates multiple frames while correcting for drift.