reagentのメーカーや取扱い企業、製品情報、参考価格、ランキングをまとめています。
イプロスは、 製造業 BtoB における情報を集めた国内最大級の技術データベースサイトです。

reagent(10) - メーカー・企業と製品の一覧

更新日: 集計期間:Aug 13, 2025~Sep 09, 2025
※当サイトの各ページの閲覧回数を元に算出したランキングです。

reagentの製品一覧

46~60 件を表示 / 全 89 件

表示件数

Monoclonal antibody production contract option service

Format conversion

Format Conversion The antibodies obtained through the Antibody Artisan's contract services come with various optional services. If an Fc region is required, we can convert the candidate antibody's Fab into full-length human, human-mouse chimeric, or human-rat chimeric forms, and deliver purified IgG molecules within 10 weeks. After cloning the genes for the VH and VL regions along with the desired constant region into a vector, we simultaneously introduce the light chain and heavy chain vectors into mammalian cells for expression. For more details, please also refer to the selection of antibody formats in the service flow. For pricing, please inquire for confirmation. *This is an optional service for antibodies produced through the Antibody Artisan service. *This menu is not applicable to antibodies you already possess. *For more details, please refer to the PDF materials or feel free to contact us.

  • Other contract services
  • Other services

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録

Human DNA removal tool 'MolYsis'

Selective enrichment of bacterial and fungal DNA! Human DNA can be removed regardless of sample volume. [Trial campaign in progress]

"MolYsis" is a tool that removes human DNA and concentrates bacterial and fungal DNA from liquid samples. Technically, it is effective in a short series of steps for the selective lysis of blood cells and the quantitative degradation of released human DNA (>99%). After the lysis solution is concentrated by centrifugation, the microorganisms are treated with reagents that break down the cell walls of gram-positive bacteria, gram-negative bacteria, and fungi. It has been clinically evaluated for a wide range of microbial lysis, demonstrating effectiveness against over 200 species of bacteria and 65 species of fungi. From December 1, 2021, to March 31, 2022, Jumatsu Trading will offer a trial kit of "MolYsis Complete5" from this series at a special price. For more details, please check our website's news section (December 1, 2021: Announcement). [Features] - Removes human DNA - Selectively concentrates bacterial and fungal DNA - Removes PCR inhibitors - Dissolves a wide range of bacteria and fungi *For more details, please refer to the PDF materials or feel free to contact us.

  • image_16.png
  • Other Nucleic Acid/DNA Research
  • Real-time PCR
  • Other Amplification/PCR

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録

NMR reagent 'Deuterated compounds and reference materials'

We offer a wide range of deuterated compounds used for NMR measurements!

We offer a variety of deuterated compounds used for nuclear magnetic resonance spectroscopy (NMR). We have products with different deuteration levels available for your specific needs. Additionally, we provide both general packaging options ranging from 10 mL to 500 mL, as well as ampoule packaging for single-use. Our ampoule packaged products come with labels attached, making it easy to verify the contents even without a box. The removed labels can be directly affixed to your lab notebook, facilitating the management of the solvents used. For more details, please download our catalog or feel free to contact us.

  • NMR用試薬 重水素化合物・基準物質_OGA-01(202210).jpg
  • Chemicals

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録

☆High Purity Reagents☆ Various warranty items! Please choose according to your analysis needs.

We offer high-quality reagents. A wide range of options to choose from, tailored to your analysis needs and budget!

┏━━━━┓ ☆Recommended☆ ≪Reagents for Metal Analysis≫ ┗━━━━┛ ▷Reduction of metal impurities using specially treated bottles ▷Suitable for UGR and harmful metal measurement, atomic absorption analysis ▷First choice for precise analysis ▼Product Lineup▼ ■Ultra High Purity Reagent Ultrapur An ultra-high purity reagent developed for ultra-trace analysis ■High Purity Solvent Primepure A new reagent with the highest purity specifications among commercially available reagents and broader guarantee items ■Reagents for Atomic Absorption Analysis AAS Reagents used for pretreatment, extraction solvents, masking agents, chelating agents, and interference suppressants in atomic absorption analysis. Guarantees low-level metal impurities for multiple items compared to those for precise analysis. ■Reagents for Harmful Metal Measurement PMA Reagents for measuring harmful metals at environmental standard levels. Specification values set from several ppb to several tens of ppb for each harmful metal. ■Reagents for Precise Analysis UGR This reagent group has a quality that meets or exceeds special grade standards defined by JIS standards. It particularly standardizes and guarantees metals as impurities.

  • 直しトリミング図1.png
  • Chemicals

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録

We also have standard substances for 'ion chromatography reagents' for HPLC.

In addition to standard solutions and standard liquids that you can use with confidence in ion chromatography, we also offer a variety of mixed standard solutions that are convenient for creating calibration curves!

"Ion chromatography reagents" are HPLC reagents. Ion chromatography measures standard substances and actual samples, performing qualitative and quantitative analysis by comparing the peaks of the standard substances with those of the actual samples. Our company offers a variety of ion chromatography reagents. In addition to standard stock solutions and standard solutions, we also provide various mixed standard solutions that are convenient for screening and creating calibration curves. 【Product Lineup】 ◇ 1 mol/L ethylenediamine solution ◇ 500 mg/mL ethylenediamine solution ◇ 1 mol/L nitric acid (1N) ◇ 1 mol/L sodium carbonate solution ◇ 1 mol/L sodium bicarbonate solution ◇ Sodium 4-pyridinecarboxylate ◇ 10 mol/L sulfuric acid (20N) ◇ 1 mol/L tartaric acid solution …etc 【Related Products】 We offer JCSS standard solutions used for tap water quality testing. As a JCSS registered business, we provide various standard solutions for water quality testing based on the measurement law traceability system. Please use them together. For more details, please download the catalog or feel free to contact us.

  • RDB-04_水道水試験に用いるJCSS標準液について.png
  • RCA-00液体クロマトグラフィー用関連製品.png
  • Chemicals

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録

Environmental allergen-related reagent "Dust Mite Allergen Measurement ELISA Kit"

For trace measurement of dust mite allergens! A kit for measuring allergen concentration, capable of measuring from flour as well.

The "Dust Mite Allergen Measurement ELISA Kit" is a kit designed to measure the concentrations of the major allergens Der p 1 and Der f 1 or Der 2 from house dust mites and storage mites. By using this kit, you can sensitively detect allergens derived from dust mite bodies or feces, which serve as indicators when assessing contamination levels of dust mite allergens in indoor environments. <NEW> By using the dilution solution (flour) for the dust mite allergen kit, it has become possible to efficiently extract and measure dust mite allergens (Der p 1, Der f 1, Der 2) contained in flour, which was difficult to extract with conventional dilution solutions. 【Features】 - Detection of allergens from dust mite bodies or feces - High-sensitivity quantification using ELISA - High reproducibility with an average C.V. value of less than 5% - All necessary reagents included - Uses a separate plate that can be used in multiple sessions *For more details, please refer to the catalog or feel free to contact us.

  • Other laboratory equipment and containers
  • Other physicochemical equipment
  • Other measurement, recording and measuring instruments

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録

Standard Protocol for Inducing Atopic Dermatitis by "Biosta AD"

This is an introduction to the standard protocol for inducing atopic dermatitis using BioSta AD.

In the atopic dermatitis model using Biosta AD, after destroying the skin barrier with 4% SDS, the product is applied to the back and ear area of the mice at a dose of 100 mg/mouse twice a week. The induction period is approximately 3 weeks (for a total of 6 applications). Ultimately, a total of 600 mg of the product will be applied. In this model, symptoms begin to appear from 1 to 2 weeks after the start of application, with an incidence rate of about 80% observed at 3 to 4 weeks. 【Initial Induction Method】 ○(1) NC/Nga mice (female, from Charles River Japan, aged 10 weeks or older) are anesthetized (with ether), and the back and ear areas are shaved with clippers, followed by the application of an appropriate amount of depilatory agent to remove hair. ○(2) After wiping off the depilatory agent, 100 mg of Biosta AD is evenly applied to the back and ear areas. ○(3) After application, the mice are returned to their breeding cages. For more details, please contact us or download the catalog.

  • Public Testing/Laboratory
  • Other services

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録

Ultra-high purity reagent Ultrapur-100, excellent cost performance.

"High-purity reagents for ultra-trace analysis" guarantees metal impurity content at the 100 ppt level while achieving excellent cost performance. Recommended for ultra-trace metal analysis.

"Ultrapur-100" is a grade of ultra-high purity reagent that can be easily used for a wider range of applications. With the improvement in sensitivity and accuracy of analytical instruments, the analysis of ultra-trace elements is being conducted in fields such as the semiconductor industry, new materials, biochemistry, and environmental chemistry (drinking water quality, soil contamination). For trace metal analysis in such fields, including ICP-AES and ICP-MS, "Ultrapur-100" is highly recommended. 【Features】 ■ The highest grade reagent after Ultrapur - EL grade The purity achieved by the top-tier commercial reagent Ultrapur is not always required. "Ultrapur-100" ensures high purity next to Ultrapur and can be widely used for general metal analysis. ■ Adoption of specialized containers A newly developed special container made of extremely clean high-density polyethylene is used. It successfully minimizes contamination of the contents while keeping costs to a minimum. ■ Outstanding cost performance It achieves exceptional cost performance among commercially available high-purity reagents. It can be widely and easily utilized. For more details, please download the catalog or feel free to contact us.

  • 超高純度試薬ウルトラピュア(Ultrapur)_RAA-02(202203).jpg
  • RAA-00用途別製品 試験規格一覧.png
  • Chemicals

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録

Reagent for Residual Solvent Testing for Pharmaceutical Testing

We guarantee the quality through residual solvent suitability testing. We also offer convenient 100 mL packaging for single use.

The residual solvent test measures the amount of organic solvents present in pharmaceuticals using methods such as gas chromatography, confirming that organic solvents do not exceed the limit values in the pharmaceuticals. Most commercially available general reagents have not had low boiling point impurities removed, making them unusable as the impurity peaks from the reagents overlap with the peaks of the substances being measured on the GC chart. This product reduces the content of low boiling point compounds such as methanol and guarantees quality through a unique residual solvent compatibility test. The expiration date is displayed on the label, and a certificate of analysis can also be issued. Additionally, we offer single-use reagents packaged in 100mL. Please make use of these for recording and managing reagents.

  • Chemicals

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録

Test method for water quality standard item "color" - "Related products for color measurement."

We have prepared reagents based on conventional water quality standards! The 'Color Standard Solution (1000 degrees)' is prepared by dissolving potassium chloroplatinate and cobalt chloride in hydrochloric acid.

"Colorimetric Measurement Related Products" are reagents used in testing methods targeting the water quality standard item "color." Our company has traditionally offered reagents and standard products based on water quality standards. The "Color Standard Solution (1000 degrees)" is prepared by dissolving potassium chloroplatinate and cobalt chloride in hydrochloric acid. This stock solution is then step-diluted to create a color standard series, which is tested using colorimetric methods and transmittance measurement methods. In addition to this, our company also handles various standard products for water quality testing. ◇ Pesticide standard solutions ◇ Standard solutions for volatile organic compound analysis ◇ Standard solutions for disinfection byproduct analysis ◇ Standard solutions for phenolic compound analysis ◇ Standard solutions for surfactant analysis ◇ Standard solutions for musty odor analysis ◇ Other organic compound standard solutions ◇ Phthalate ester standard products ◇ Standard solutions for metal analysis ◇ Standard solutions for ion chromatography ◇ Standard solutions for turbidity, color, and pH testing For more details, please refer to our company’s published page or feel free to contact us.

  • Chemicals

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録

Introduction to Custom Monoclonal Antibody Production Service Case Studies vol. 9

Not mediated by animal immunity! An article introducing successful cases of antibodies that distinguish specific oxidized Cys.

DJ-1 is a 21 kDa protein, and we present a successful case of producing antibodies that specifically recognize the oxidized form of the Cys residue at position 106 (C106) of DJ-1. We have attempted to obtain antibodies that specifically recognize the oxidized C106 through the production of polyclonal antibodies via immunization in rabbits and monoclonal antibodies via immunization in mice, but we were unable to obtain the desired antibodies in either case. Here, we introduce a method for producing antibodies that do not involve animal immunization and are selected entirely in vitro, along with the results of verifying the specificity of the obtained antibodies. 【Contents】 ■1. What is DJ-1 ■2. Strategic Screening  ・2-1. Antigen Design  ・2-2. Panning and ELISA Screening  ・2-3. Cross-reactivity Confirmation by ELISA ■3. Western Blotting and Immunoprecipitation ■4. Summary *For detailed content of the article, please refer to the related links. *For detailed specifications, please refer to the PDF document or feel free to contact us.

  • Other services
  • Other contract services
  • Contract manufacturing

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録

Total nitrogen and total phosphorus analysis reagents

Yokogawa Electric Corporation's "Dedicated Reagents for Total Nitrogen and Total Phosphorus Automatic Measurement Device"

We sell the following products as reagents specifically for the NP600 automatic measurement device for total nitrogen and total phosphorus manufactured by Yokogawa Electric Corporation. Additionally, we offer a variety of standard solutions that serve as calibration span solutions, allowing for the adjustment of nitrogen and phosphorus concentrations in various ways. Please use them together. 【Related Products】 ◆ Nitrogen Standard Solution 100mL ◆ Phosphorus Standard Solution 100mL ◆ Distilled Water 500mL 20L

  • Chemicals

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録

Disposable Reagent Series for Pharmaceutical Testing

This is a 100 mL package ideal for single use. Please make use of it for contamination prevention, reducing waste, and effective use of storage space!

Our company offers a series of single-use reagents for pharmaceutical testing in 100 mL packaging. The PIC/S GMP Guidelines Part 1, Chapter 6 states: "Special attention must be paid to the quality of laboratory reagents, test solutions, glassware, reference materials, and culture media. They must be prepared and managed according to the procedures. The level of management should be appropriate to their intended use and the available stability data." It is expected that the management of reagents once opened will be based on stability data after opening. This product is available in small, single-use packaging, which allows for reduced waste and effective use of storage space, and eliminates the need for stability confirmation after opening. There is no concern about cross-contamination, allowing for safe use.

  • Chemicals

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録

Reagents for BOD and COD measurement

Water Quality Standards "Reagents for BOD and COD Measurement"

● Reagents for COD Measurement We offer reagents used for measuring Chemical Oxygen Demand (CODMn) by potassium permanganate (KMnO4) as specified by official methods. *Official methods: Industrial water testing methods (JIS K0101) / Factory wastewater testing methods (JIS K0102) / Mine water and wastewater testing methods (JIS M0202) / Sewage testing methods ● Reagents for BOD Measurement Our BOD seed is a blended inoculum that contains bacteria capable of isolating various organic substances, formulated to achieve BOD values equivalent to those obtained from inoculum prepared from sewage sludge. The bacteria included in the formulation are produced and blended under strict product and lot management after being individually cultured. For more details, please refer to the catalog below.

  • Chemicals

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録

Palladium(II) chloride

Introduction of raw materials such as conductive paste, electronic components, and palladium plating!

Palladium(II) chloride is a dark red or dark brown hygroscopic powder. It is slightly soluble in water and ether, and dissolves in water with hydrochloric acid to form a yellow-brown clear solution. Manufactured using high-purity palladium metal with a purity of 99.95% or higher, through a unique method in fully sealed equipment. It maintains a quality that sufficiently meets the standards of Japanese Industrial Standards (JIS-K8154) for reagent grade and has received high evaluations. 【Applications】 ■ Conductive paste ■ Electronic component plating ■ Plating ■ Catalyst ■ Reagent *For more details, please refer to the PDF document or feel free to contact us.

  • Other polymer materials

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録