We have compiled a list of manufacturers, distributors, product information, reference prices, and rankings for stage.
ipros is IPROS GMS IPROS One of the largest technical database sites in Japan that collects information on.

stage Product List and Ranking from 124 Manufacturers, Suppliers and Companies | IPROS GMS

Last Updated: Aggregation Period:May 06, 2026~Jun 02, 2026
This ranking is based on the number of page views on our site.

stage Manufacturer, Suppliers and Company Rankings

Last Updated: Aggregation Period:May 06, 2026~Jun 02, 2026
This ranking is based on the number of page views on our site.

  1. PI Japan Kanagawa//Electronic Components and Semiconductors
  2. null/null
  3. Nippon Blower Co.,LTD. Tokyo//Industrial Electrical Equipment
  4. 4 ミラック光学 Tokyo//Testing, Analysis and Measurement
  5. 5 シグマ光機 Tokyo//Testing, Analysis and Measurement

stage Product ranking

Last Updated: Aggregation Period:May 06, 2026~Jun 02, 2026
This ranking is based on the number of page views on our site.

  1. Stirred temperature control stage Nippon Blower Co.,LTD.
  2. Manual stage equipped with a self-locking mechanism that has obtained a patent <Video now available> ミラック光学
  3. PIMag Linear Motor XY Axis Stage 'L-731/V-731' PI Japan
  4. 4 Deben's "Tensile Stage" エルミネット
  5. 5 Rotary Pump DUO Series / 2-Stage Type 伯東 本社

stage Product List

511~540 item / All 704 items

Displayed results

1-axis stage L80 / 150

A tabletop stage kit that can be used for everything from education to research and development.

This is a tabletop stage assembly kit that achieves a compact, lightweight design and an easy-to-introduce price. It features versatility to accommodate stepping motors from various manufacturers and can also support DC motors as an option. The product can be combined in pairs to be used as an X-Y stage, allowing for a flexible configuration with excellent expandability. Its high operability makes it suitable for a wide range of learning, from the basics to advanced applications in machine control. Since its release in 2003, it has been adopted as a teaching material for control technology in many educational institutions and companies, and it has a long track record of being utilized over the years. It demonstrates stable performance in research and development as well as experimental environments, combining practicality and reliability.

  • Other FA equipment
  • stage

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Swing Stage

To improve work efficiency, it is essential to start with creating a safe scaffolding.

The "Swing Stage" is a foldable permanent access stairway. It is suitable for safe and efficient loading and unloading operations. It is widely used for crossing from shipping areas, such as those for petroleum products, to tank trucks and tank cars in manufacturing plants and other shipping locations. Additionally, it can be used as a step for crossing spaces in various locations, not just for tank car loading. 【Features】 ■ Foldable permanent access stairway ■ Designed to fit the environment of the facility *For more details, please download the PDF or feel free to contact us.

  • Other safety and hygiene products
  • stage

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Chromato Stage

We offer a variety of data import units! Packed with features suitable for creating papers and reports.

The "ChromatoStage" that we handle is a chromatographic data processing device that allows for a variety of system configurations. You can change the display format to your preference, and the printing layout can be designed freely. High-quality reports can be created without the need to install Excel or Word. Additionally, you can connect as many data importers as needed, and with the expansion features, it is also possible to import data from devices such as pressure gauges and thermometers. 【Features】 ■ Various system configurations are possible ■ Change the display format to your preference ■ Freely design the printing layout ■ Excellent compatibility with Excel ■ Separate installation of PCs for analysis and processing to improve efficiency *For more details, please download the PDF or feel free to contact us.

  • Other Chromatograph
  • Other separation and analysis equipment
  • stage

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Global market size of micro-positioning stages.

This report systematically organizes the medium to long-term growth trends of the micro-positioning stage market from both quantitative and qualitative analysis perspectives.

This document provides an explanation of the global market size for micro-positioning stages. It covers an overview of micro-positioning stages, analysis by product type, analysis by application, analysis by company, analysis by region, technological innovations, and future market outlook. Our company, based in Tokyo, integrates industrial information from around the world and provides reports to support corporate decision-making. *For more details, please download the PDF or feel free to contact us.*

  • others
  • stage

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Temperature control stage with stirrer for pharmaceuticals

Precise temperature control while stirring! Improving the efficiency and accuracy of reaction control.

In the pharmaceutical industry, precise management of temperature and stirring is crucial for the efficiency and quality of reactions. This is especially true for reactions sensitive to temperature changes or those requiring uniform mixing, where accurate temperature control and efficient stirring are essential. Inadequate temperature management or insufficient stirring can lead to delays in reactions or the formation of by-products. Our temperature-controlled stage with a stirrer provides precise temperature control within a range of -10°C to 80°C and stirring capabilities of up to 1200 rpm. This significantly enhances the precision and efficiency of reaction control in pharmaceutical research and development. 【Application Scenarios】 - Drug synthesis - Chemical reactions - Cell culture - Reagent preparation 【Benefits of Implementation】 - Improved reproducibility of reactions - Enhanced experimental efficiency - Contribution to the production of high-quality pharmaceuticals

  • セット断熱材.png
  • グラフ.JPG
  • 構成例.JPG
  • Stirrer
  • stage

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Temperature control stage with stirrer for chemical synthesis

Control the temperature while stirring! Improve the efficiency and accuracy of synthetic reactions.

In the field of chemical synthesis, precise control of reaction temperature and uniform stirring significantly influence the efficiency and quality of reactions. This is especially true for reactions sensitive to temperature changes or those requiring uniform mixing, where appropriate temperature management and stirring are essential. Inadequate temperature control or stirring can lead to delays in reactions, the formation of by-products, and decreased yields. Our temperature-controlled stage with a stirrer offers precise temperature control in the range of -10°C to 80°C and stirring capabilities of up to 1200 rpm. This enables easy realization of optimal reaction conditions in chemical synthesis, enhancing the reproducibility and efficiency of experiments. 【Application Scenarios】 - Organic synthesis reactions - Inorganic synthesis reactions - Polymerization reactions - Catalytic reactions - Crystallization 【Benefits of Implementation】 - Optimization of reactions through precise control of reaction temperature - Improved reaction efficiency through uniform stirring - Reduction of by-products by suppressing temperature gradients - Enhanced reproducibility of experiments - Adaptability to a variety of reactions

  • セット断熱材.png
  • グラフ.JPG
  • 構成例.JPG
  • Stirrer
  • stage

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Temperature control stage with stirrer for food quality evaluation

Temperature control while stirring! Streamlining food quality evaluation.

In the food industry, temperature management is extremely important for quality assessment. The deterioration and degradation of food are greatly influenced by temperature, so evaluations under precise temperature control are required. In particular, temperature changes can significantly affect the results in component analysis and microbiological testing. A temperature-controlled stage with stirring allows for more accurate and efficient evaluations by simultaneously managing temperature and agitation in food quality assessments. 【Application Scenarios】 - Component analysis of food - Microbiological testing - Quality retention tests - Dissolution tests for food additives 【Benefits of Implementation】 - Improved accuracy of evaluations by simultaneously managing temperature and stirring - Increased efficiency of experiments and reduced working time - Establishment of a highly reproducible experimental environment - Compatibility with a variety of food samples

  • セット断熱材.png
  • グラフ.JPG
  • 構成例.JPG
  • Stirrer
  • stage

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Temperature control stage with stirrer for environmental science.

It is possible to maintain temperature while stirring within a temperature range of -10℃ to 80℃. Insulation material set included.

In the field of environmental science, the temperature management of samples is a crucial factor that affects the accuracy of pollutant analysis. Particularly in the analysis of volatile organic compounds, precise temperature control and uniform stirring are required to prevent the loss or alteration of components due to temperature fluctuations. If proper temperature management and stirring are not implemented, the reliability of the analysis results may be compromised. A temperature-controlled stage with stirring capability addresses these challenges and supports accurate analysis. 【Application Scenarios】 - Extraction and concentration of pollutants - Temperature control of chemical reactions - Dissolution and mixing of samples 【Benefits of Implementation】 - Simultaneous temperature management and stirring - Improved reproducibility and reliability of analysis - Enhanced experimental efficiency

  • セット断熱材.png
  • グラフ.JPG
  • 構成例.JPG
  • Stirrer
  • stage

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Temperature control stage with stirrer for polymer polymerization

Control the polymerization reaction while stirring within a temperature range of -10℃ to 80℃.

In the polymer material polymerization reaction, precise control of the reaction temperature and uniform stirring are crucial factors that influence the quality of the product. In particular, polymerization reactions are sensitive to temperature changes, making appropriate temperature management essential. Additionally, efficient stirring is required to maintain the uniformity of the reaction mixture. Insufficient temperature control can affect the rate of the polymerization reaction and the molecular weight distribution of the products. Our temperature-controlled stage with a stirrer addresses these challenges and contributes to the efficiency and quality improvement of polymerization reactions. 【Application Scenarios】 - Research and development of polymer materials - Polymer synthesis - Optimization of polymerization reaction processes 【Benefits of Implementation】 - Synthesis of high-quality polymer materials through precise control of reaction temperature - Improved reaction efficiency through uniform stirring - Establishment of a highly reproducible experimental environment

  • セット断熱材.png
  • グラフ.JPG
  • 構成例.JPG
  • Stirrer
  • stage

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

10nm feedback stage system (precision positioning device)

Positioning with 10nm resolution! Excellent reproducibility, stage with a stroke of 20 to 200mm.

■High Resolution and Reproducibility The built-in motor driver in the controller allows the stage to operate with a resolution of 10nm, and the optical linear encoder integrated into the stage reads the position for feedback control, resulting in high resolution and excellent reproducibility. ■Long Stroke It can move up to 200mm. This enables precise positioning and sample retraction with a single stage. ■Control The controller is equipped with several communication interfaces, allowing the stage to be controlled by inputting command strings from a PC or similar device. ■Movable Type In addition to linear motion, we also offer lifting types and micro-rotation options. For more details, please download the catalog or contact us.

  • Other microscopes
  • Other inspection equipment and devices
  • stage

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Submicron feedback stage system (precision positioning device)

Positioning with sub-micron resolution! Excellent reproducibility with built-in encoder, stage with a stroke of 20 to 400 mm.

■High Resolution and Reproducibility The built-in motor driver in the controller allows the stage to operate with sub-micron resolution, and the optical linear encoder integrated into the stage reads the position and performs feedback control, resulting in high resolution and excellent reproducibility. The stage controller operates at a resolution of either 100nm (0.1μm) or 50nm (0.05μm). ■Long Stroke It can move up to a maximum of 400mm. This enables precise positioning and sample retraction with a single stage. ■Control The controller is equipped with several communication interfaces, allowing the stage to be controlled by inputting command strings from a PC or similar device. ■Movable Type In addition to linear motion, we also offer lift types and micro-rotation options. For more details, please download the catalog or contact us.

  • Other microscopes
  • Other inspection equipment and devices
  • stage

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Vacuum-compatible 10nm feedback stage system

For positioning applications within a vacuum chamber, it features built-in linear encoders for positioning with a resolution of 10nm and a maximum movement range of 100mm.

A precision positioning device (feedback stage system) that achieves a resolution of 10nm and a reproducibility of ±20nm with an integrated optical linear encoder. It can be used in a vacuum chamber with a vacuum level of up to 10^-4 Pa. Compared to positioning devices that use piezo technology, it is utilized in a wide range of applications due to its "low cost," "easy control," and "large stroke capability." The stroke ranges from 20mm to 100mm. If you are facing challenges with positioning, please feel free to contact us. ■ For more details, please download the catalog or contact us.

  • Other microscopes
  • Other inspection equipment and devices
  • Other FA equipment
  • stage

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Submicron Feedback Stage FS-3200X/XY

"Precision positioning device" with high resolution, high positioning repeatability, and excellent position holding capability after positioning!

This is a high-resolution positioning stage with an optical linear scale built into the center of the stage, reducing detection errors. It has a stroke of 200mm with a resolution of either 50nm or 100nm (*1). Thanks to our in-house developed linear scale and unique feedback control circuit, it offers high resolution, excellent positioning repeatability, and position holding capability after positioning. Equipped with a slowdown sensor, it minimizes the impact during stops at the stroke end. (*1) In combination with the feedback stage controllers FC-414 or FC-114.

  • Other FA equipment
  • stage

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Vacuum-compatible submicron feedback stage, lift type

Usable in a vacuum! Positioning stage for the Z-axis with built-in linear encoder and sub-micron resolution!

This is a high-resolution Z-axis positioning stage equipped with an optical linear scale. It achieves a stroke of either 5mm or 10mm with a resolution of either 50nm (*1) or 100nm (*2). It has been treated for outgassing and can be used in a vacuum. Thanks to its unique design, it minimizes changes in the tilt of the table surface, which is common in Z-axis configurations, and is equipped with a self-developed linear scale and proprietary feedback control circuit, providing high resolution, excellent positioning repeatability, and position retention after positioning. (*1) Combination with feedback stage controller FC-411 (*2) Combination with feedback stage controller FC-111

  • Other FA equipment
  • stage

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Vacuum-compatible 10nm feedback stage with 50mm operation.

High-performance positioning stage with 10nm resolution and 50mm operation, capable of reproducibility using position information from a linear encoder in a vacuum environment.

A stage was created with components that do not outgas for use in a vacuum. Therefore, the stage can be introduced into the vacuum chamber. It features full closed-loop control based on the positional information from an embedded optical linear encoder, providing high-precision repeatability in positioning. It can operate with a 50mm stroke at a resolution of 10nm.

  • Other FA equipment
  • Other microscopes
  • Other inspection equipment and devices
  • stage

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Vacuum-compatible 10nm feedback stage with 20mm operation.

High-performance positioning stage with a built-in linear encoder operating at 10nm resolution, usable in a vacuum.

This is a vacuum-compatible feedback stage equipped with outgassing measures. It can be directly introduced into a vacuum chamber. It has a built-in optical linear encoder, and based on the position information detected by the encoder, it performs full closed-loop control, resulting in high-precision repeatability in positioning. It can achieve positioning with a 20mm stroke and a resolution of 10nm.

  • Other FA equipment
  • Other microscopes
  • Other inspection equipment and devices
  • stage

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Vacuum-compatible submicron feedback stage with 100mm operation

Usable in a vacuum! Positioning stage with built-in linear encoder and sub-micron resolution.

The stage position is detected using a built-in optical linear encoder, enabling full closed-loop control, which results in high resolution and excellent position reproducibility. It has been treated for outgassing and can be used in a vacuum. It can operate within a range of 100mm, with a resolution of "50nm" or "100nm" depending on the controller.

  • Other FA equipment
  • stage

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Vacuum-compatible submicron feedback stage with 50mm operation

Vacuum-compatible positioning stage with sub-micron resolution and a range of 50mm.

It is driven using a stepping motor and ball screw, which provides excellent position holding capability. The built-in optical linear encoder detects the stage's position and performs full closed-loop control, resulting in high resolution and excellent position reproducibility. It has been treated for outgassing and can be used in a vacuum. It can operate within a range of 50mm with a resolution of either 50nm or 100nm (depending on the controller).

  • Other FA equipment
  • stage

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Vacuum-compatible submicron feedback stage with 40mm operation.

High-resolution positioning stage with built-in encoder for use in a vacuum.

The built-in optical linear encoder detects the position of the stage and performs full closed-loop control, resulting in high resolution and excellent position reproducibility. Since it is driven by a stepping motor and ball screw, it has excellent position holding capability. Due to the use of components that are less likely to outgas in the vacuum chamber, the stage can be placed inside the vacuum chamber. It can operate within a range of 40mm and can be controlled with a resolution of "50nm" or "100nm" (depending on the controller).

  • Other FA equipment
  • stage

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Vacuum-compatible submicron feedback stage with 20mm operation

Feedback stage with submicron resolution usable in a vacuum.

The built-in optical linear encoder detects the position of the stage table and feeds the position information back to the controller, resulting in high resolution and excellent position reproducibility. Since it is driven by a stepping motor and ball screw, it has excellent position retention. As a countermeasure against outgassing, lubricants, wires, and motors have been replaced with vacuum-compatible products, allowing for use within a vacuum chamber. It can operate within a range of 20mm and can be controlled with a resolution of "50nm" or "100nm" (depending on the controller).

  • Other FA equipment
  • stage

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Vacuum-compatible submicron feedback stage, micro-rotation type

Usable in a vacuum! Stage for adjusting rotation direction

It is equipped with an optical linear encoder, allowing it to detect the position of the movable parts of the stage, which enables the controller to perform closed-loop control based on that position information, resulting in excellent position reproducibility. The resolution can be operated at "0.00005" or "0.0001" resolution, depending on the controller. It has been treated for outgassing, making it usable in a vacuum.

  • Other FA equipment
  • stage

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Feedback Stage System Comprehensive Catalog (Atmosphere/Vacuum) 5th Edition

Achieve nanometer resolution, high reproducibility, and high retention with linear encoders! Custom manufacturing is also available.

This is the comprehensive catalog for our high-resolution positioning devices for atmospheric use and vacuum-compatible high-resolution positioning devices (feedback stage systems) that we design, manufacture, and sell. It covers specifications, configurations, prices, and more for feedback stages, feedback stage controllers, cables, and options. We also accept orders for custom and special products. Please feel free to consult us. 【Features of Atmospheric Systems】 We develop, manufacture, and sell compact positioning devices with built-in linear scales. They are used in semiconductor-related equipment, communication-related applications, and optical systems for advanced research. 【Features of Vacuum-Compatible Systems】 Since our establishment, we have leveraged the know-how gained from producing custom products to provide high resolution and high precision reproducibility for vacuum applications. *You can view the comprehensive catalog by downloading the PDF. Please feel free to contact us via the inquiry form for any requests. Additionally, the link below introduces examples of custom product manufacturing.

  • Other FA equipment
  • stage

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

BIXY Stage STD System (NK) "B30117"

A joystick that further improves the operability of speed and feed mode switching!

While being an open control system, it achieves positioning reproducibility equivalent to that of electric stages with linear scales from other companies. In addition to a joystick that further improves the operability of speed and feed mode switching, it also comes with a button-type keypad that allows for fine movements. 【Features】 ○ Stage movement speed and unit display can be changed as desired ○ Standard compatibility with K standard holders (compatible with incubators and thermo plates from various manufacturers) → "LCI's Chamlide LC, TC series," "Tokai Hit's Stage Top Incubator, Thermo Plate series," etc. ○ Can be mounted on NIKON inverted microscopes ○ Compatible with imaging software → "MDJ's Meta series software (MetaMorph, etc.) compatible," "Mitsui & Co.'s bioimaging software LuminaVision compatible" For more details, please contact us or download the catalog.