"Subsidance Correction" - Watch the "TerraTech Method" in a video.

Correcting floor subsidence caused by ground subsidence without stopping operations. "Subsidence correction and void filling" without dismantling the floor.

The "Teratech Method" is a construction technique that corrects the tilt, subsidence, and unevenness of concrete floors in factories, warehouses, stores, and shopping centers by injecting a special urethane resin called "Teratech Resin," without damaging the floor or halting operations. **Features of the Teratech Method:** - Injection holes smaller than a one-yen coin, with a diameter of 6 mm. There is no need to break the floor. - Specialized technicians perform corrections while measuring in millimeters. - Minimum load-bearing capacity of 19 tons per square meter. - Weighs approximately 10 kg per cubic meter, making it lightweight. *This is 1/20th the weight of concrete. - Short curing time of about 30 minutes, allowing large trucks to pass immediately after construction. - Standard daily construction area is 200 square meters (this may vary depending on construction conditions). Available nationwide in Japan. Construction achievements: Over 300 cases annually from Hokkaido to Okinawa. Total construction area: Over 1,177,000 square meters. We can handle projects ranging from 30 square meters to several thousand square meters for factories, warehouses, shopping centers, and more. Available nationwide in Japan, 24/7, feel free to consult us! Toll-free number: 0120-873-835

  • 注入イラスト.jpg
  • 動画で見る床の沈下修正テラテック工法.jpg
  • others

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Unevenness Correction" Correction of uneven concrete floors "TerraTech Method

We will quickly fix the "wobbling" and "unevenness" at the floor joints caused by the hollow space under the floor without damaging it!

Unevenness and bumps in the concrete floor that hinder the smooth operation of forklifts. Every time the forks pass, it rattles, causing damage to the cargo, items to fall from the forks, and requiring a reduction in speed, which significantly decreases work efficiency, doesn't it? Not only does the decline in work efficiency pose a problem, but it also presents numerous safety hazards for employees. With the "Teratec Method," we can eliminate the unevenness and bumps in the concrete floor without breaking it and without halting operations, all in a short time. Since we do not break the floor, there is almost no noise, debris, or dust generated. We offer services 24 hours a day, 365 days a year, including weekends and holidays! For adjustments to the unevenness and bumps in concrete floors in factories, warehouses, cold storage facilities, and distribution centers, please feel free to contact us. Toll-free number: 0120-873-835

  • DSC00028.JPG
  • others

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Settlement Correction and Void Filling: TerraTech Method Case Study Collection Giveaway

Over 4,500 construction projects! With the extension of the lifespan of structures being considered now, the number of projects in factories, warehouses, and stores is rapidly increasing!

The Teratech method quickly corrects the tilting, sagging, distortion, and unevenness of floor slabs in factories, warehouses, stores, and shopping centers caused by ground subsidence by injecting a special urethane resin called "Teratech resin." ◆ Teratech Method * A cavity survey under the floor is conducted in advance. 1. Measure the tilt of the floor. 2. Drill holes with a diameter of 6 millimeters, smaller than a one-yen coin, at the correction points. 3. Use proprietary equipment to inject resin under the floor slab. 4. The injected resin begins to expand instantly. This expansion force compacts and strengthens the ground while pushing the floor upward. 5. Correct the floor while measuring its movement in millimeters. 【Features】 ■ Lifts from underneath the floor, so no damage to the floor. ■ Short construction period; can level an area of 200 square meters in one day. ■ Cost-effective compared to demolition and restoration work. ■ No demolition work means it is quiet and produces no waste. ■ Does not use water, so it does not dirty products or machinery. By addressing floor subsidence, tilting, and cavity filling, we can ensure the safety of workers and customers, improve work efficiency, and enhance the internal environment, leading to better business performance. Please feel free to contact us. Toll-free number: 0120-873-835

  • others

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Currently Offering Free Samples] Case Studies of Floor Leveling Repair Work

We will correct the floor tilt and subsidence without stopping operations! Introducing examples of the "Terra Tech Method" for correcting subsided concrete floors!

Our company conducts the "TerraTech Method," a sinking correction technique that adjusts floor tilts, subsidence, steps, and voids in buildings such as factories, warehouses, stores, and schools, where it is difficult to halt operations, without breaking the existing floor. The "TerraTech Method" involves injecting a special urethane resin under the concrete slab floor, which levels the floor using its expansion force. Compared to traditional concrete replacement methods, the construction period is about 1/10 of the time, and there is no need to remove goods, machinery, or install large plants. We are offering free materials that introduce examples of sinking correction work carried out using the "TerraTech Method." The materials include detailed information about the situation before construction and the reasons for inquiries. Please feel free to download and review them. [Overview of Materials] ■ Case Study: Funabori Co., Ltd. (Manufacturing Factory) ■ Case Study Collection Vol. 1: Various case studies are introduced ■ Customer Feedback Vol. 1-4: Feedback from customers who have actually undergone construction *For more details, please refer to the PDF materials or feel free to contact us. Toll-Free Number: 0120-873-835

  • okyakusamanokoe_matome.jpg
  • others

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

The first step in warehouse automation is the "Terra Tech Method" from the level of the floor.

Currently, with the advancement of delivery management and warehouse automation utilizing AI and big data, the levelness of the facility's floor is an important theme for the introduction of automation equipment.

If the floor is not level... ☑ The installation of high-rise racks will require liner support, causing anxiety! ☑ There is a possibility that high-pick operators may fall, making it unusable! ☑ There may be obstacles to the operation of AGVs (automated guided vehicles)! ☑ High stacking of pallets and nestainers may become tilted and impossible! The "TerraTech Method" levels the floor's tilt and subsidence in a short construction period. ◆ What is the TerraTech Method? Is your warehouse's concrete floor tilted or sunken? The TerraTech Method involves injecting TerraTech resin beneath the concrete floor, using its expansion force to return the sunken floor to level and fill any voids underneath. This patented method corrects the "tilt," "sinking," "steps," and "deflection" of the concrete floor without damaging it, and does so in a short period. Please feel free to contact us. Toll-free number: 0120-873-835

  • 倉庫自動化工法比較.png
  • Other machine tools

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Numerous achievements in public works! Settlement floor correction method 'Teratec Method'

Teratec method: It's not just about replacement and resurfacing! A floor repair method!

【Numerous achievements with the Ministry of Land, Infrastructure, Transport and Tourism and various local governments】 Quickly and fundamentally resolve issues such as floor tilting, unevenness in public facilities, and voids under roads. Are you still considering just replacement or resurfacing? The Teratec method is chosen for public works as well as warehouses, factories, and stores, with a track record of 4,200 projects! ▼ What is the Teratec method? The "Teratec method" is a patented technique that injects Teratec resin under concrete floors to fill voids caused by sinking, restoring the floor to a level position using the resin's expansion force. "Using the expansion force of Teratec resin, we lift and level sinking or tilted floors." This innovative idea has made it possible to restore floors to a level position quickly without destruction. 【Features of the Teratec method】 - No. 1 market share in Japan* (4,200 construction achievements) - Available for construction 24 hours a day, 365 days a year - Reliable technology with patented and former NETIS registration (QS-080007) * (Market share for sinking correction work using urethane injection method / based on our research) ▶ For more details, please view the catalog from "PDF Download." Feel free to contact us by phone (0120-873-835) or email (info@mainmark.co.jp).

  • others

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Construction Case] Vibration Suppression in Precision Parts Manufacturing Factory - Void Filling Work

"The earthen floor is sagging, causing the machine to vibrate." "The vibration of the machine affects product accuracy." Quickly resolved with the up-con method.

This time, we will introduce a case study of a precision parts manufacturing factory in Saitama Prefecture. Due to ground subsidence, cracks and deflection occurred in the concrete floor, causing vibrations in the machinery. To prevent the impact of vibrations on product accuracy, we carried out subsidence correction work to alleviate deflection and void filling work under the concrete floor. The Upcon method was adopted because it allows for construction without moving the machinery and without stopping operations. 【Site Information】 Saitama Prefecture / Precision Parts Manufacturing Factory Construction Area: 287 square meters Maximum Subsidence: 44 mm Maximum Void Volume: 50 mm Construction Period: 3 days You can view detailed construction information in the PDF download below.

  • Machinery and equipment installation/dismantling/relocation

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Achieve the levelness of floors necessary for factory and warehouse automation! 'TerraTech Method'

The first step in automating factories and warehouses starts with the level of the floor. You can rely on us for issues related to floor tilt and subsidence.

The "Teratec Method" is a technique for leveling floors that have tilted or settled in a short construction period. In the current era where AI and big data are advancing in delivery management and the automation of factories and warehouses, the leveling of facility floors is an important theme for the introduction of automated equipment. We solve concerns such as: - "The installation of high racks has become unstable for liner compatibility." - "There is a risk of the high-pick work vehicle tipping over, making it unusable." - "The stacking of pallets and nestainers is becoming tilted and cannot be done." 【Features】 - Does not damage the floor - Short construction period - Patent obtained - Over 4,200 construction achievements *For more details, please refer to the PDF materials or feel free to contact us. Toll-free number: 0120-873-835

  • 3物流倉庫での施工の様子.jpg
  • 1事象のイラストまとめol.png
  • 2事象のイラストまとめol.png
  • others

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Residential Upcon Method (Concrete Floor Slab Settlement Correction Method)

For sinking correction work on slab foundation houses due to earthquakes or ground subsidence, leave it to Upcon!

Do you have any of these concerns? ✓ The house is leaning ✓ There are gaps in the windows and sliding doors ✓ The entrance and windows do not close properly ✓ There is a sense of discomfort when entering the room ✓ Doors open and close on their own ✓ Experiencing dizziness or headaches ✓ There are cracks or wrinkles in the wallpaper ✓ Balls roll on their own ✓ Water flow has worsened ✓ The water in the aquarium is not level With Upcon, we can quickly correct the tilt of your home! ■ Upcon Method (Concrete Floor Slab Settlement Correction Method) We inject special foam urethane resin under the concrete of the foundation of the house where the tilt has occurred, making adjustments in millimeter increments while constantly monitoring the level. The injected resin expands in a short time, compressing and reinforcing the ground while lifting the foundation to restore it to a straight position. We conduct surveys and construction anywhere in Japan, 365 days a year, including weekends and holidays. Our qualified in-house staff will assist you!

  • others

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Upcon Co., Ltd. Company Profile

Upcon is a company that solves problems with 'urethane.' We quickly correct floor sinking, unevenness, tilting, and gaps using rigid polyurethane resin.

Upcon quickly corrects concrete floors that have experienced sinking, unevenness, tilting, gaps, and vibrations due to ground subsidence and earthquakes without halting operations. We repair tilted concrete floors in factories, warehouses, and stores, which are the bases of corporate production and sales activities, as well as in general residences affected by earthquakes and ground subsidence. Additionally, we engage in public works projects using technologies developed through various research and development projects to restore the functionality of aging social infrastructure such as roads, airports, ports, and agricultural waterways. ■ Features of the Upcon Method 1. Short construction period: The construction time is one-tenth that of conventional methods. 2. No operational stoppage: No need to move machinery or cargo. 3. Comprehensive high technical capability: 100% in-house employees. 4. Compact construction system: Quick restoration of the current state is possible. 5. Reduced risk of re-sinking compared to conventional methods. We provide total support from on-site investigation to repair planning and construction, all handled responsibly by our in-house staff. Our specialized and experienced staff propose optimal repair plans tailored to the customer's site. Upcon Co., Ltd. was newly listed on the Nagoya Stock Exchange Next Market on December 26, 2022.

  • others

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Factory/Warehouse] Upcon Method (Concrete Floor Slab Settlement Correction Method)

If you have tilting, steps, or gaps in factory or warehouse floors due to earthquakes or ground subsidence, then Upcon!

Do you have any of these concerns? ✓ Unable to secure the level of machinery ✓ Warehouse items are not stacked straight ✓ Uneven surfaces make it difficult for forklifts to operate ✓ Cracks are forming in the floor ✓ Gaps are appearing between the floor, walls, and ceiling ✓ Water is pooling due to floor sagging ✓ Insects are appearing inside the building We can solve these problems with Upcon! ■ Upcon Method (Concrete Floor Slab Settlement Correction Method) Concrete floors that have settled, become uneven, tilted, or developed gaps due to ground subsidence and other causes. The Upcon method corrects such floors quickly without stopping operations. Since it can be performed without breaking the existing floor, the construction period is significantly reduced to about 1/10 compared to conventional methods (concrete replacement). There is no need to remove items or machinery, or to install large plants, allowing for construction without halting operations. We conduct surveys and construction anywhere in Japan, 365 days a year, including weekends and holidays. Our in-house staff, equipped with the necessary skills and qualifications, will assist you! *For more details, please visit the external link page or feel free to contact us.

  • others

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Store] Upcon Method (Concrete Floor Slab Settlement Correction Method)

Tilt, steps, and gaps in the store floor caused by earthquakes or ground subsidence. We will make corrections quickly without stopping operations!

Do you have any of these concerns? ✓ Cracks in the floor ✓ Gaps in the floor, walls, or ceiling ✓ Issues with the automatic door opening and closing ✓ Shopping cart moves on its own when you let go ✓ The floor is sagging ✓ Feeling dizzy and losing balance when entering the store ✓ Product racks are tilted We can solve these problems with Upcon! ■ Upcon Method (Concrete Floor Slab Settlement Correction Method) Concrete floors that have settled, have steps, tilts, or gaps due to ground subsidence and other causes. The Upcon method corrects such floors quickly without stopping business. Since it is performed without breaking the existing floor, the construction period is significantly reduced to about 1/10 compared to traditional methods (concrete replacement). There is no need to move or remove product racks or refrigerated cases, and installation of large plants is also unnecessary, allowing for construction without halting operations. We conduct surveys and construction anywhere in Japan, 365 days a year, including weekends and holidays. Our own staff, equipped with skills and qualifications, will assist you! *For more details, please refer to the external link page or feel free to contact us.

  • others

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Correcting floor subsidence and tilt in stores/commercial facilities without stopping operations!

Floor subsidence caused by earthquakes and ground sinking. The subsidence correction specialist, Upcon, will fix the existing floor without demolition and in a short period! Over 3,000 successful cases nationwide!

□ Store fixtures and product racks are tilted □ Shopping carts move on their own □ Luggage and products are not stacked straight □ Gaps are forming in the floor, walls, and ceiling □ Cracks are appearing in the floor The issues caused by floor subsidence, tilting, and unevenness will be resolved by "Subsidance Correction Specialist Upcon." With the Upcon method, polyurethane resin is injected under the existing concrete floor, and the pressure from the foaming strengthens the ground and lifts the floor. In principle, there is no need to demolish the existing floor, and there is no need to move heavy product racks or store fixtures, significantly shortening the construction period compared to conventional methods. Additionally, we can accommodate construction limited to nighttime outside of business hours, allowing us to correct floor subsidence without stopping operations.

  • Contract measurement

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Quickly correct the factory floor's slope and the gaps under the floor with rigid polyurethane foam resin!

Correcting floor tilts caused by earthquakes and ground subsidence without stopping operations and in a short period! No need to move machines or equipment! Also suppressing any concerning vibrations from the machines!

■ The machine cannot be leveled. ■ The machine is tilted and vibrating. ■ Malfunctions are occurring in the machine, leading to an increase in defective products. ■ Gaps have formed in the floor, walls, and ceiling. ■ Cracks have appeared in the floor. The "Upcon Method" solves problems caused by floor tilting and sagging due to earthquakes or ground subsidence, as well as voids and gaps that have formed beneath the floor, using polyurethane resin for quick repairs. 【What is the Upcon Method?】 Small holes with a diameter of 16mm are drilled into the existing concrete floor where subsidence has occurred. While continuously monitoring the level in millimeter increments, polyurethane resin is injected. The resin injected beneath the floor expands under pressure in a short time, compacting and strengthening the ground, improving bearing capacity, and pushing the concrete back to a level position. The final strength of the resin is achieved in about 60 minutes. Even if voids have formed beneath the floor, the same method is used to fill those voids. Since the existing concrete floor is repaired without demolition, the construction period is significantly reduced compared to conventional methods. The polyurethane can lift the floor with a foaming pressure of up to 10 tons per square meter, eliminating the need to move heavy equipment or materials. The deformation of the floor is corrected without stopping the production line.

  • Contract measurement
  • Other contract services
  • others

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Road Concrete Pavement Slab Settlement Correction Method Achieves Early Lifting of Traffic Restrictions

We will correct the irregularities such as steps and flapping that have occurred in the concrete pavement slabs using specially developed high-strength polyurethane resin, without excavation and within a short construction period.

Using a specially developed high-strength polyurethane resin, we will correct the deformation such as steps and fluttering that occur in concrete pavement slabs commonly used on highways, as well as fill the gaps and voids that have developed under bridge deck slabs, all without breaking the existing concrete pavement and within a short construction period. Injecting polyurethane resin will also improve the loosening of the subgrade. Additionally, it enables the lifting of joints with polyurethane resin along with the bearing slab, fundamentally resolving the issue of correcting the step at the joint, which traditionally required excavation and long-term continuous restrictions or road closures.

  • Repair Agent