List of Contract Analysis products
- classification:Contract Analysis
271~315 item / All 2039 items
Reduce the workload from handling heavy objects! Here are five case studies that solved customer challenges! We are also accepting free consultations and tests tailored to your work!
- Other conveying machines
A belt grinding machine that has been in use for about 50 years since 1973. In addition to trust and proven results, the lineup is also extensive.
- Other machine tools

Belt grinding machine "Veda Machine" has high durability and a wide range of service parts.
The "Bader Machine" is our belt grinder that boasts excellent polishing performance for each individual unit. By selecting models and types according to the shape and size of the workpiece, and by equipping it with a polishing belt suitable for the task, it can flexibly accommodate a wide variety of items across various fields. Please make extensive use of it for high-efficiency polishing and grinding, reduction of work time, labor-saving, and standardization of tasks. 【Lineup】 ■ Portable type BP-K (air motor type) ■ Made-to-order machine PC-1 (wheel centerless), BC (standard dust cover) ■ Installed type BM (basic type), SBA-1, BH-2 ■ Wheel type SBD-4S, SBD-7, BWd *For more details, please download the PDF or contact us.
We evaluate the isotope ratio by measuring specific mass numbers using ICP-MS.
- Contract Analysis
- Contract Inspection
We will conduct halogen measurement using IC or ICP.
- Contract Analysis
- Contract Inspection
We will conduct measurements of inorganic substances contained as impurities using ICP.
- Contract Analysis
- Contract measurement
- Contract Inspection
Qualitative and quantitative analysis of elements (B to U) contained on the sample surface will be conducted.
- Contract measurement
- Contract Analysis
- Analytical Equipment and Devices
We conduct analysis of trace elements and light elements suitable for material analysis and foreign substance analysis.
- Contract measurement
- Contract Analysis
- X-ray fluorescence analyzer
Measurements of elements, ions, and compounds that elute under specific conditions will be conducted.
- Contract Analysis
- Contract measurement
- Contract Inspection
Free basic analysis seminar held! Please make use of it to enhance your company's analysis skills.
- Contract Analysis
- Contract Inspection
- Contract measurement
Nano to angstrom resolution! Observation of fine morphology and composition analysis at the atomic level.
- Electron microscope
- Contract Analysis
- Contract measurement
Correction of sensitivity coefficients and sputtering rates across all depths in response to changes in the sample matrix, enabling high-precision depth profile analysis.
- Contract Analysis
- Secondary ion mass spectrometer
- Ion implantation equipment
GDMS is a method suitable for evaluating trace impurities (ppm-ppb wt) and can simultaneously measure almost all elements except for gas components with stable isotopes.
- Contract Analysis
- Contract measurement
- Mass Spectrometer
We evaluate abnormalities inside the device non-destructively.
- Contract Analysis
- Other electronic parts
- Transistor
We undertake part of the supplier quality management tasks, such as quality verification of OEM products from supplier factory audits and market research to assist in determining the authenticity of m...
- Other contract services
- Contract Analysis
- Other services
We accept evaluation testing and failure analysis of automotive electronic components and electronic devices.
- Other contract services
- Contract Analysis
- Lithium-ion battery

[Free Seminar] Corrosion Environment Solutions for Ensuring Reliability and Longevity of Electronic Equipment and Facility Maintenance (Introduction of Corrosion Environment Diagnosis Kit Eco Checker II)
The usage environment of electronic devices varies, and the impact of corrosion caused by various environmental factors tends to increase. The reliability and lifespan of electronic devices heavily depend on the environment in which they are used. Corrosive substances originating from hot springs, volcanoes, waste, and rivers can corrode electronic components, printed circuit board wiring, connector contacts, and switch contacts of electrical equipment, potentially leading to serious issues. This content is recommended for those who want to solve such challenges: • Does the atmosphere of the operating environment lead to failures in electronic devices? • I want to reduce the risk of failure in harsh environments such as hot springs and wastewater treatment plants. • I want to conduct environmental surveys in large factories with fewer personnel and man-hours. • I want to prolong the lifespan of aging infrastructure as much as possible. We will introduce our original corrosion environment diagnostic kit, Eco Checker II, as well as methods for diagnosing corrosion environments.
Introducing our facilities used for reliability evaluation and environmental testing of materials for industrial products and consumer goods, not limited to electronic components and devices!
- Contract Analysis
- Contract Inspection
- Contract Analysis
We select the optimal non-destructive analysis from lock-in infrared thermal analysis, 3D X-ray tomography, ultrasonic testing (SAT), etc., and narrow down the abnormal areas.
- Contract Analysis
- Microcomputer
- Other semiconductors
Are you prepared for future PFAS regulations? Leave the analysis of PFAS (per- and polyfluoroalkyl substances) in products to us! We are also offering explanatory materials.
- Contract Analysis
- Ingredient analysis
- Other physical property measurements and component analysis
From investigating the mechanisms of failures and malfunctions to proposing improvement measures and verifying their effectiveness, our expert engineers provide total support!
- Other contract services
- Contract Analysis
- Capacitor

[Free Seminar] Corrosion Environment Solutions for Ensuring Reliability and Longevity of Electronic Equipment and Facility Maintenance (Introduction of Corrosion Environment Diagnosis Kit Eco Checker II)
The usage environment of electronic devices varies, and the impact of corrosion caused by various environmental factors tends to increase. The reliability and lifespan of electronic devices heavily depend on the environment in which they are used. Corrosive substances originating from hot springs, volcanoes, waste, and rivers can corrode electronic components, printed circuit board wiring, connector contacts, and switch contacts of electrical equipment, potentially leading to serious issues. This content is recommended for those who want to solve such challenges: • Does the atmosphere of the operating environment lead to failures in electronic devices? • I want to reduce the risk of failure in harsh environments such as hot springs and wastewater treatment plants. • I want to conduct environmental surveys in large factories with fewer personnel and man-hours. • I want to prolong the lifespan of aging infrastructure as much as possible. We will introduce our original corrosion environment diagnostic kit, Eco Checker II, as well as methods for diagnosing corrosion environments.
We will identify specific species names from samples such as tree branches, insect tissue fragments, and fish fillets!
- Contract Inspection
- Contract Analysis
Real-time PCR detection with excellent sensitivity and specificity measures the presence or absence of specific materials!
- Contract Analysis
- Contract Inspection
Supports up to 306 varieties! Leave your genetically modified food testing to us.
- Contract Inspection
- Contract Analysis
We guarantee A2 milk, which has gained attention in recent years, through DNA analysis!
- Contract Inspection
- Contract Analysis
Detects DNA from seven types of livestock, including hamburger and sausage.
- Contract Analysis
- Contract Inspection
Analysis can be performed on samples in various conditions thanks to our unique preprocessing technology!
- Other Testing Contract
- Contract Analysis

Specification verification and failure analysis through reliability testing.
Our company conducts consistent analysis from reliability testing to failure analysis. This allows us to confirm whether the samples meet the specifications, as well as to identify and observe the defective areas of failed samples. We propose and implement tests and analyses tailored to our customers' requests and objectives, assisting from cause investigation to problem resolution. Please feel free to contact us when you need our services. 【Analysis Flow】 ■ Specification confirmation of semiconductor devices through reliability testing ■ Identification of defective areas and observation of failure locations using TEM ・ Identification of defective areas through EMS/OBIRCH analysis ・ Observation of failure locations using TEM
Reverse engineering that reveals the information engineers want through accurate circuit restoration.
- Contract Analysis
- Circuit board design and manufacturing
- Printed Circuit Board
The reason why it broke, such as plastic or metal, is left on the fracture surface.
- Contract Analysis
- Contract measurement
- Contract Inspection
If the surface of the gold-plated terminals of connectors, etc., has discolored or has foreign substances attached, there is a possibility that the gold plating is corroded.
- Other contract services
- Contract Analysis
- Contract Inspection
Establishment of a support system for disposal! Quick response and flexible consultation system.
- Contract Analysis
Starting from April 2025, government subsidies will begin! A speedy response and flexible consultation system are in place.
- Contract Analysis
Same-day report at the shortest! The lowest price in the industry! For asbestos analysis, choose Vester!!
- Contract Analysis
This is a list of devices used for analysis, evaluation, and testing services at AITES.
- Contract Analysis

Reverse bias test of power devices (up to 2000V)
At Aites Co., Ltd., high-temperature reverse bias testing (HTRB) for evaluating the oxide film and junction of power devices can be applied up to a maximum of 2000V. By monitoring the leakage current during the test, the degradation status of the device can be grasped in real-time. Since the power supply is independent, if one device fails during the test, it will not affect the other devices. Additionally, it is possible to set a failure criterion (current value) and to cut off the power supply to the device deemed faulty at the time of failure judgment. 【Specifications and Service Details】 ■ Test Voltage: Up to a maximum of DC 2000V ■ Applied Current: Up to a maximum of 14mA ■ Number of Test Devices: Up to a maximum of 8 (independent power supply) ■ Compatible Modules: TO-247, TO-220, etc. (other packages require consultation regarding connection methods) ■ Measurement Content: Monitoring of leakage current ■ Temperature Range: Up to a maximum of 200°C (85°C/85% in high temperature and high humidity conditions)
TEM (Transmission Electron Microscope) meets a wide range of requirements for observing failure sites of electronic components, length measurements, elemental analysis, crystal structure analysis, and...
- Contract Analysis
- Other semiconductors
- Other contract services

Announcement of the introduction of Talos F200E
Our company will introduce the FEI "Talos F200E" transmission electron microscope system. Compared to conventional models, the resolution for TEM and STEM has improved, and performance has been significantly enhanced, allowing for EDS analysis with four detectors. Additionally, it is equipped with features such as drift-corrected frame integration (DCFI), which accumulates multiple frames while correcting for drift.
Sample 1, including comparison with Ref! Summarize and conduct candidate analytical methods.
- Contract Analysis

Analysis of organic-inorganic composite materials using FT-IR and EDX.
We will introduce an example of analyzing organic-inorganic composite materials using FT-IR and SEM-EDX. FT-IR measurements were conducted on the glossy and non-glossy areas of a PET bottle label, and the IR spectra differed between the glossy and non-glossy areas. Since the non-glossy area resembles the spectrum of acrylic resin, it is considered that the main component is acrylic resin. Additionally, SEM-EDX measurements were performed on both the glossy and non-glossy areas, and EDX spectra and backscattered electron images were obtained, revealing that the non-glossy area contained sulfur (S) and barium (Ba), which were not detected in the glossy area.
We provide quick and accurate solutions based on technology and experience for quality initiatives that consider performance, reliability, disposal, and recycling from the product planning stage.
- Contract Analysis
- Contract Inspection
- Analytical Equipment and Devices

Evaluation of various implementation substrates
At Aites Co., Ltd., we provide a wide range of technical services for evaluation tests of printed circuit boards (mounted boards) equipped with electronic components. We conduct reliability tests, solder joint observations, whisker observations, and cross-sectional observations. We have IPC-A-610 certified IPC specialists on staff who can assist with observations in accordance with international standards, consultations, and various observation-related concerns. Additionally, we offer services such as X-ray observations, appearance inspections, and shape measurements, so please feel free to consult with us when needed.
We will identify and observe the defective areas of power devices such as diodes, MOS-FETs, and IGBTs.
- Contract Analysis
- Transistor
- Analytical Equipment and Devices

Announcement of the introduction of Talos F200E
Our company will introduce the FEI "Talos F200E" transmission electron microscope system. Compared to conventional models, the resolution for TEM and STEM has improved, and performance has been significantly enhanced, allowing for EDS analysis with four detectors. Additionally, it is equipped with features such as drift-corrected frame integration (DCFI), which accumulates multiple frames while correcting for drift.
By applying chemical etching, ion milling, and FIB processing to mechanical polishing, we will analyze various metal joints, starting with lead-free solder.
- Contract Analysis
- Other contract services
- Contract measurement

Cryogenic ion milling cross-section processing example (rubber products)
We will introduce a case where cross-sections were created and observed by method regarding the adhesive parts of the tires of pull-back cars. When conducting SEM observations of the created cross-sections, fillers present inside the rubber were confirmed. It was found that the dispersion state of the fillers and the condition of the adhesive interface were not clear with fracture by liquid nitrogen or mechanical polishing. In contrast, the cross-sections created by cryo ion milling allow for clear observation of the dispersion state of the fillers contained within the rubber and the condition of the adhesive interface with the plastic substrate.
It is possible to observe cross-sections while observing FIB processing in real time.
- Contract Analysis
- Other contract services
- Electron microscope

Power device failure location / Slice & View three-dimensional reconstruction
I will introduce the three-dimensional reconstruction of failure locations using the Slice & View function of FIB-SEM. Continuous SEM images of the structure are obtained, and the resulting images are corrected for positional misalignment between the SEM images and visualized in three dimensions using 3D construction software (Avizo). By combining the position identification technique for cross-sectioning the failure location with the Slice & View function, it is possible to obtain continuous SEM images that retain the defective state and include information before and after the abnormal area.
If it is 5 micrometers or larger, foreign object IR data can be obtained.
- Contract Analysis
- Analytical Equipment and Devices
- Other contract services

Micro FT-IR imaging measurement
We would like to introduce the "Microscopic FT-IR Imaging Measurement" that we conduct. It allows for the visualization of the distribution of substances as a two-dimensional image within a specified plane. It becomes possible to evaluate changes in the distribution of substances that are difficult to assess with regular point measurements through visual images.
We will report rapid analysis results using various sampling techniques regarding foreign substances that significantly impact the yield of electronics products.
- Contract Analysis
- Analytical Equipment and Devices
- Other contract services

Chemical Analysis Concierge Service
We would like to introduce our "Chemical Analysis - Trust Us Service." When conducting component analysis of foreign substances or stains on products, it can be challenging to determine whether organic analysis or inorganic analysis is more suitable, and which specific analysis within organic or inorganic is the most appropriate. We provide a comprehensive service for customers who are struggling with the selection of analysis methods. Since each analysis device can measure different targets, it is necessary to choose a method that fits the purpose based on the information available.
TOF-SIMS can analyze light elements and inorganic substances as well as large organic molecules.
- Analytical Equipment and Devices
- Contract Analysis
- Other contract services

Chemical Analysis Concierge Service
We would like to introduce our "Chemical Analysis - Trust Us Service." When conducting component analysis of foreign substances or stains on products, it can be challenging to determine whether organic analysis or inorganic analysis is more suitable, and which specific analysis within organic or inorganic is the most appropriate. We provide a comprehensive service for customers who are struggling with the selection of analysis methods. Since each analysis device can measure different targets, it is necessary to choose a method that fits the purpose based on the information available.
We provide comprehensive support for customers facing reliability issues with overseas manufactured LCD displays, from reliability testing to failure analysis and material analysis.
- Contract Inspection
- Testing Equipment and Devices
- Contract Analysis

In-chamber imaging during constant temperature and humidity testing.
Our company conducts environmental testing using a constant temperature and humidity chamber with a front glass window and a camera, allowing us to capture and monitor the operational status, such as screen displays, during the tests. During environmental testing using equipment like constant temperature and humidity chambers, monitoring the condition of the test subjects with loggers (for voltage, current, resistance, temperature, etc.) is widely practiced. However, monitoring the operational status of equipment during testing can be difficult unless the test equipment is equipped with dedicated external outputs. For samples where monitoring with loggers is challenging, we combine a constant temperature and humidity chamber with a front glass window option, a camera, and monitoring software to conduct environmental tests while capturing and monitoring the condition of the test equipment.
It has high safety and can be used in various environments! Consistent analysis is possible.
- Contract Analysis

Case study of failure analysis of oxide-based all-solid-state batteries
We will introduce a case where a series of analyses from failure location identification to cross-sectional observation was conducted on oxide-based all-solid-state batteries that were destroyed by reliability testing. Thermal analysis revealed a tendency for strong heat generation on the side, and X-ray transmission observation showed a white linear contrast anomaly near the boundary where heat generation was observed in the X-ray transmission image. It is suspected that some abnormality is occurring in the white line area. When cross-sectional SEM observation was performed on the area where the anomaly was visible, layer delamination was observed. It is speculated that the positive (negative) electrode layers expanded and contracted repeatedly due to reliability testing, leading to delamination between the current collector and the electrolyte layer.
The Raman spectrum reflects the functional groups of organic compounds! The curing reaction can be estimated to some extent.
- Contract Analysis
- plastic

Chemical Analysis Concierge Service
We would like to introduce our "Chemical Analysis - Trust Us Service." When conducting component analysis of foreign substances or stains on products, it can be challenging to determine whether organic analysis or inorganic analysis is more suitable, and which specific analysis within organic or inorganic is the most appropriate. We provide a comprehensive service for customers who are struggling with the selection of analysis methods. Since each analysis device can measure different targets, it is necessary to choose a method that fits the purpose based on the information available.
Observing the behavior of strain in thermal shock testing! The test materials used are FR-1 and FR-4.
- Contract Analysis

Strain measurement of power module package resin.
We would like to present the results of strain measurements conducted by attaching strain gauges and thermometers to the surfaces of power modules, both in the mounted state on a circuit board and in the unmounted state. In the mounted module, a slight delay in temperature change was observed, and correspondingly, the change in strain also appeared to be delayed. This is believed to be due to the slower transfer of heat to the module when it is mounted. At Aites, we conduct temperature cycle tests and temperature-humidity cycle tests, during which we can simultaneously measure the strain occurring in the mounted components. Please feel free to consult with us.
We provide consistent evaluation and analysis from material properties to the mechanisms of their functional expression!
- Contract Analysis

Optical film light transmission characteristics
At Aites Co., Ltd., we conduct "optical film analysis." Optical films used in smartphones and other devices have various functions depending on their structure and materials. We measured the light transmittance of privacy protection films at different angles and combined cross-sectional observation with Raman analysis to investigate the mechanism of function manifestation. By investigating the transmittance characteristics of privacy protection films using angle-variable spectrophotometry, we were able to analyze the mechanism of function manifestation through cross-sectional observation and Raman analysis. At Aites, we provide consistent evaluation and analysis from material properties to the mechanisms of function manifestation.