List of Analysis Services products
- classification:Analysis Services
46~90 item / All 563 items
Reduce the workload from handling heavy objects! Here are five case studies that solved customer challenges! We are also accepting free consultations and tests tailored to your work!
- Other conveying machines
It won't break even after 1 million repetitions! A mat switch with reliable operation, high durability, and low price. Suitable for options in machine tools as well. Please consult us about delivery t...
- Sensors
Mechanical grinding allows for a wide range of processing and observation! We will propose appropriate processing and observation methods or combinations.
- Analysis Services
- Other contract services

About the curing temperature of epoxy resin free from hazardous substances.
We conducted measurements to reconfirm the temperature of heat generation during curing, following the change to a non-toxic epoxy resin. When using a large amount of resin, we apply heat generation prevention treatment for resin embedding. Without this treatment, the temperature can rise up to 138°C during curing. However, by applying the heat generation prevention treatment even with a large amount of resin, we were able to keep the heat generation during curing within 30°C.
If any issues arise, detailed analysis will also be provided! A simplified analysis for customers considering the introduction of overseas LCDs.
- Analysis Services

Observation of Conductive Particle Shape in COG Implementation
We will introduce the observation of the shape of conductive particles in COG implementation. ICs and liquid crystal panels are implemented using the COG method with ACF (anisotropic conductive film). A resin ball is used as the core, and a metal layer (such as nickel or gold) for conductivity is deposited on its surface. During connection, the particles deform appropriately to electrically connect the IC and the panel. To confirm the degree of particle deformation and connection status, cross-sectional observations were conducted, revealing that the particle deformation was at a "medium" level, indicating an appropriate degree of deformation. By examining the deformation of conductive particles from both the planar and cross-sectional directions, we can explore the correlation with display defects. Please feel free to contact us for any inquiries regarding panel-related defects.
We conduct environmental testing, as well as non-destructive observation and electrical property measurements.
- Analytical Equipment and Devices
- Analysis Services

Appearance observation and measurement services
We would like to introduce our "Appearance Observation and Measurement Service." We are equipped with a variety of devices to meet your needs, including appearance observation before and after reliability testing, solder joint observation, as well as dimensional measurements and surface roughness measurements of various components. You can also leave the pre-observation processing to us. Our company has IPC-certified IPC specialists on staff. We provide assistance with observations, consultations, and solutions to various observation-related concerns in accordance with international standards.
Easily explain the technical capabilities of Aites by analyzing molecular structures with diagrams and tables!
- Analysis Services
- Structural Analysis

Analysis of trace metal elements in liquid crystals
We will introduce a case where ICP measurement was conducted using panels before and after reliability testing, along with quantification. The liquid crystal molecules in an LCD are oriented within the panel, and the display is controlled by changes in the orientation state of the liquid crystal due to voltage. When ionic substances, such as metal elements, are present inside the panel, the liquid crystal may not drive correctly, leading to display defects. It is known that ionic substances can increase due to contamination during manufacturing or long-term use, making it important to quantify and understand them as part of panel quality. Metal ions can be quantitatively analyzed using ICP analysis, and depending on the differences in pretreatment methods and detection sensitivity, ICP-AES and ICP-MS are used selectively. [Analysis Content] ■ Comparison of metal element content using ICP-AES analysis ■ Comparison of metal element content using ICP-MS analysis For more details, please refer to the related products and catalog below.
We will introduce an example of analysis using EBSD for screws (Cu2Zn).
- Analytical Equipment and Devices
- Analysis Services

Example of analysis of compounds at the SAC solder and Ni pad interface.
We will introduce an example of the analysis of compounds formed at the interface between Sn-Ag-Cu solder and NiP pads. At the interface of NiP pads and Sn-Ag-Cu solder, compounds such as (Ni,Cu)3Sn4 and (Cu,Ni)6Sn5 grow, and surface analysis using EDX shows the distribution of Ni, Cu, and Sn within these compounds. The EBSD method is a technique that analyzes based on the crystallographic information of the sample. By combining it with elemental analysis using EDX, it is possible to estimate the composition, and in some cases, it may be possible to analyze using crystallographic data for Ni3Sn4 and Cu6Sn5 as substitutes.
Visualize the features that appear in the graph! You can check the distribution of crystal sizes and the orientation of crystal directions.
- Analytical Equipment and Devices
- Analysis Services

Example of analysis of compounds at the SAC solder and Ni pad interface.
We will introduce an example of the analysis of compounds formed at the interface between Sn-Ag-Cu solder and NiP pads. At the interface of NiP pads and Sn-Ag-Cu solder, compounds such as (Ni,Cu)3Sn4 and (Cu,Ni)6Sn5 grow, and surface analysis using EDX shows the distribution of Ni, Cu, and Sn within these compounds. The EBSD method is a technique that analyzes based on the crystallographic information of the sample. By combining it with elemental analysis using EDX, it is possible to estimate the composition, and in some cases, it may be possible to analyze using crystallographic data for Ni3Sn4 and Cu6Sn5 as substitutes.
The EBSD method allows for the estimation of crystal states and residual stresses! Here is an example of BGA analysis.
- Analytical Equipment and Devices
- Analysis Services

Example of analysis of compounds at the SAC solder and Ni pad interface.
We will introduce an example of the analysis of compounds formed at the interface between Sn-Ag-Cu solder and NiP pads. At the interface of NiP pads and Sn-Ag-Cu solder, compounds such as (Ni,Cu)3Sn4 and (Cu,Ni)6Sn5 grow, and surface analysis using EDX shows the distribution of Ni, Cu, and Sn within these compounds. The EBSD method is a technique that analyzes based on the crystallographic information of the sample. By combining it with elemental analysis using EDX, it is possible to estimate the composition, and in some cases, it may be possible to analyze using crystallographic data for Ni3Sn4 and Cu6Sn5 as substitutes.
We will introduce an example of crystal analysis of intermetallic compounds at solder joints.
- Analytical Equipment and Devices
- Analysis Services

Example of analysis of compounds at the SAC solder and Ni pad interface.
We will introduce an example of the analysis of compounds formed at the interface between Sn-Ag-Cu solder and NiP pads. At the interface of NiP pads and Sn-Ag-Cu solder, compounds such as (Ni,Cu)3Sn4 and (Cu,Ni)6Sn5 grow, and surface analysis using EDX shows the distribution of Ni, Cu, and Sn within these compounds. The EBSD method is a technique that analyzes based on the crystallographic information of the sample. By combining it with elemental analysis using EDX, it is possible to estimate the composition, and in some cases, it may be possible to analyze using crystallographic data for Ni3Sn4 and Cu6Sn5 as substitutes.
Observe the changes before and after compression on the copper plate! You can compare the half-life of the crystal grain size before and after compression.
- Analytical Equipment and Devices
- Analysis Services

Example of analysis of compounds at the SAC solder and Ni pad interface.
We will introduce an example of the analysis of compounds formed at the interface between Sn-Ag-Cu solder and NiP pads. At the interface of NiP pads and Sn-Ag-Cu solder, compounds such as (Ni,Cu)3Sn4 and (Cu,Ni)6Sn5 grow, and surface analysis using EDX shows the distribution of Ni, Cu, and Sn within these compounds. The EBSD method is a technique that analyzes based on the crystallographic information of the sample. By combining it with elemental analysis using EDX, it is possible to estimate the composition, and in some cases, it may be possible to analyze using crystallographic data for Ni3Sn4 and Cu6Sn5 as substitutes.
We will introduce an example of the analysis of EBSD patterns (Kikuchi patterns) at gold wire bond joints.
- Analytical Equipment and Devices
- Analysis Services

Example of analysis of compounds at the SAC solder and Ni pad interface.
We will introduce an example of the analysis of compounds formed at the interface between Sn-Ag-Cu solder and NiP pads. At the interface of NiP pads and Sn-Ag-Cu solder, compounds such as (Ni,Cu)3Sn4 and (Cu,Ni)6Sn5 grow, and surface analysis using EDX shows the distribution of Ni, Cu, and Sn within these compounds. The EBSD method is a technique that analyzes based on the crystallographic information of the sample. By combining it with elemental analysis using EDX, it is possible to estimate the composition, and in some cases, it may be possible to analyze using crystallographic data for Ni3Sn4 and Cu6Sn5 as substitutes.
By combining various methods suitable for failure modes, we can consistently address everything from the identification of defective nodes to physical analysis.
- Other analyses
- Contract Analysis
- Analysis Services
Pre-processing of SiC devices → Identification of leakage points → Physical analysis/component analysis handled seamlessly!
- Analysis Services
- Contract Analysis

Announcement of the introduction of Talos F200E
Our company will introduce the FEI "Talos F200E" transmission electron microscope system. Compared to conventional models, the resolution for TEM and STEM has improved, and performance has been significantly enhanced, allowing for EDS analysis with four detectors. Additionally, it is equipped with features such as drift-corrected frame integration (DCFI), which accumulates multiple frames while correcting for drift.
Even with SiC power devices, we can provide consistent support for cross-section preparation of specific areas, observation of diffusion layer shapes, as well as wiring structure and crystal structure...
- Analysis Services
- Contract Analysis
Check the quality status of LCD components and products! We will analyze the structures of the LCD panels using our analytical methods and expertise!
- Analysis Services
- Contract Analysis

Observation of Conductive Particle Shape in COG Implementation
We will introduce the observation of the shape of conductive particles in COG implementation. ICs and liquid crystal panels are implemented using the COG method with ACF (anisotropic conductive film). A resin ball is used as the core, and a metal layer (such as nickel or gold) for conductivity is deposited on its surface. During connection, the particles deform appropriately to electrically connect the IC and the panel. To confirm the degree of particle deformation and connection status, cross-sectional observations were conducted, revealing that the particle deformation was at a "medium" level, indicating an appropriate degree of deformation. By examining the deformation of conductive particles from both the planar and cross-sectional directions, we can explore the correlation with display defects. Please feel free to contact us for any inquiries regarding panel-related defects.
We will handle everything from the evaluation of the diffusion layer to physical analysis/chemical analysis regarding the malfunctioning part!
- Analysis Services
- Contract Analysis
- Semiconductor inspection/test equipment

Announcement of the introduction of Talos F200E
Our company will introduce the FEI "Talos F200E" transmission electron microscope system. Compared to conventional models, the resolution for TEM and STEM has improved, and performance has been significantly enhanced, allowing for EDS analysis with four detectors. Additionally, it is equipped with features such as drift-corrected frame integration (DCFI), which accumulates multiple frames while correcting for drift.
Clear publication of analysis results using polyamide imide materials and IR devices, as well as data analysis!
- Analysis Services

Chemical Analysis Concierge Service
We would like to introduce our "Chemical Analysis - Trust Us Service." When conducting component analysis of foreign substances or stains on products, it can be challenging to determine whether organic analysis or inorganic analysis is more suitable, and which specific analysis within organic or inorganic is the most appropriate. We provide a comprehensive service for customers who are struggling with the selection of analysis methods. Since each analysis device can measure different targets, it is necessary to choose a method that fits the purpose based on the information available.
Analysis of inorganic compounds such as metal oxides is also possible!
- Analysis Services
- Contract Analysis

Chemical Analysis Concierge Service
We would like to introduce our "Chemical Analysis - Trust Us Service." When conducting component analysis of foreign substances or stains on products, it can be challenging to determine whether organic analysis or inorganic analysis is more suitable, and which specific analysis within organic or inorganic is the most appropriate. We provide a comprehensive service for customers who are struggling with the selection of analysis methods. Since each analysis device can measure different targets, it is necessary to choose a method that fits the purpose based on the information available.
Examples of analysis using EBSD, such as 'Observation/Elemental Analysis' and 'Analysis by EBSD'!
- Contract Analysis
- Analysis Services
Applying advanced sample preparation techniques and failure analysis equipment for semiconductors! Investigating the causes of non-lighting and brightness degradation.
- Contract Analysis
- Analysis Services

Examples of semiconductor observation using mechanical polishing.
In the methods for cross-section preparation in semiconductor structure observation and defect analysis, CP, FIB, and mechanical polishing are mentioned, each having its own advantages and disadvantages, making it necessary to consider which method to use. In recent years, CP and FIB have become more common, and it seems that the use of mechanically polished methods, which require technical skill, is decreasing. However, it is still not something to be dismissed. While there are merits and demerits, it is possible to achieve cross-section preparation with mechanical polishing that is on par with FIB and CP. At our company, based on years of accumulated know-how, we propose the most appropriate processing method according to the observation purpose, sample composition, and structure.
Back grinding is possible with various types of semiconductors! You can observe the elements and the condition of defects.
- Analysis Services
- Semiconductor inspection/test equipment
Introducing a case study analyzing whiskers that occurred on the lead terminals of an IC package!
- Other contract services
- Contract Analysis
- Analysis Services

Example of analysis of compounds at the SAC solder and Ni pad interface.
We will introduce an example of the analysis of compounds formed at the interface between Sn-Ag-Cu solder and NiP pads. At the interface of NiP pads and Sn-Ag-Cu solder, compounds such as (Ni,Cu)3Sn4 and (Cu,Ni)6Sn5 grow, and surface analysis using EDX shows the distribution of Ni, Cu, and Sn within these compounds. The EBSD method is a technique that analyzes based on the crystallographic information of the sample. By combining it with elemental analysis using EDX, it is possible to estimate the composition, and in some cases, it may be possible to analyze using crystallographic data for Ni3Sn4 and Cu6Sn5 as substitutes.
At Omron's Yasu facility, which has a maximum 8-inch MEMS line, we respond to various customer requests from prototype to mass production in the wafer process!
- Analysis Services
- Contract Analysis
With our advanced technology, we can also create cross-sections of highly challenging samples!
- Analysis Services
- Contract Analysis

Observation of tracking camera cross-section by mechanical grinding.
I would like to introduce "Cross-sectional observation of tracking camera using mechanical polishing." Regarding the structure of the tracking camera components, when viewed from above, the lens can be identified. Although it cannot be clearly seen in the X-ray image, the lens is incorporated into the convex part. Additionally, the cross-sectional structure is similar to that of an RGB sensor, featuring a back-illuminated CMOS structure. However, since color information is not necessary for the tracking camera, there is no color filter layer. A jagged uneven shape was observed on the surface of the photodiode.
Here is an example of analysis regarding the broken part of a crab claw that was damaged due to long-term use!
- Analysis Services
- Contract Analysis

Example of analysis of compounds at the SAC solder and Ni pad interface.
We will introduce an example of the analysis of compounds formed at the interface between Sn-Ag-Cu solder and NiP pads. At the interface of NiP pads and Sn-Ag-Cu solder, compounds such as (Ni,Cu)3Sn4 and (Cu,Ni)6Sn5 grow, and surface analysis using EDX shows the distribution of Ni, Cu, and Sn within these compounds. The EBSD method is a technique that analyzes based on the crystallographic information of the sample. By combining it with elemental analysis using EDX, it is possible to estimate the composition, and in some cases, it may be possible to analyze using crystallographic data for Ni3Sn4 and Cu6Sn5 as substitutes.
Solid samples can leach ionic components into pure water! Trace ionic components in the aqueous solution can be detected with high sensitivity.
- Analysis Services
- Other contract services

Chemical Analysis Concierge Service
We would like to introduce our "Chemical Analysis - Trust Us Service." When conducting component analysis of foreign substances or stains on products, it can be challenging to determine whether organic analysis or inorganic analysis is more suitable, and which specific analysis within organic or inorganic is the most appropriate. We provide a comprehensive service for customers who are struggling with the selection of analysis methods. Since each analysis device can measure different targets, it is necessary to choose a method that fits the purpose based on the information available.
Accurately grasping defects! It is possible to conduct extensive bulk observations as well as partial magnifications, accommodating various types of observations.
- Analysis Services
- Other contract services
We undertake contract processing and manufacturing of cross-sections of various parts and materials.
- Analytical Equipment and Devices
- Analysis Services

Cryogenic ion milling cross-section processing example (rubber products)
We will introduce a case where cross-sections were created and observed by method regarding the adhesive parts of the tires of pull-back cars. When conducting SEM observations of the created cross-sections, fillers present inside the rubber were confirmed. It was found that the dispersion state of the fillers and the condition of the adhesive interface were not clear with fracture by liquid nitrogen or mechanical polishing. In contrast, the cross-sections created by cryo ion milling allow for clear observation of the dispersion state of the fillers contained within the rubber and the condition of the adhesive interface with the plastic substrate.
We conduct surface analysis, foreign substance analysis, and organic composition analysis.
- Analytical Equipment and Devices
- Analysis Services

Analysis of organic-inorganic composite materials using FT-IR and EDX.
We will introduce an example of analyzing organic-inorganic composite materials using FT-IR and SEM-EDX. FT-IR measurements were conducted on the glossy and non-glossy areas of a PET bottle label, and the IR spectra differed between the glossy and non-glossy areas. Since the non-glossy area resembles the spectrum of acrylic resin, it is considered that the main component is acrylic resin. Additionally, SEM-EDX measurements were performed on both the glossy and non-glossy areas, and EDX spectra and backscattered electron images were obtained, revealing that the non-glossy area contained sulfur (S) and barium (Ba), which were not detected in the glossy area.
Transitional thermal measurement possible power cycle testing, with a customized luminescence/OBIRCH analysis device, where a skilled team thoroughly evaluates and analyzes power devices!
- Analytical Equipment and Devices
- Analysis Services

Rubber heat aging test
Our company conducts "rubber thermal aging tests" that help evaluate the properties of materials in actual usage environments. Using a method compliant with JIS K6257 (Method for determining thermal aging characteristics of vulcanized rubber and thermoplastic rubber), rubber test pieces are suspended in a gear oven to create specimens with varying heat treatment times. Additionally, tensile tests are performed on heated natural rubber (NR) to investigate changes in mechanical properties, while hardness is measured simultaneously. Changes in the characteristics of the rubber are also examined, confirming that rubber elasticity is lost and the material becomes harder with heating.
I will introduce an example of analysis using EBSD where orientation was observed in the Al wiring.
- Analytical Equipment and Devices
- Analysis Services

Example of analysis of compounds at the SAC solder and Ni pad interface.
We will introduce an example of the analysis of compounds formed at the interface between Sn-Ag-Cu solder and NiP pads. At the interface of NiP pads and Sn-Ag-Cu solder, compounds such as (Ni,Cu)3Sn4 and (Cu,Ni)6Sn5 grow, and surface analysis using EDX shows the distribution of Ni, Cu, and Sn within these compounds. The EBSD method is a technique that analyzes based on the crystallographic information of the sample. By combining it with elemental analysis using EDX, it is possible to estimate the composition, and in some cases, it may be possible to analyze using crystallographic data for Ni3Sn4 and Cu6Sn5 as substitutes.
I will introduce an example of analysis using EBSD for pipes (austenitic).
- Analytical Equipment and Devices
- Analysis Services

Example of analysis of compounds at the SAC solder and Ni pad interface.
We will introduce an example of the analysis of compounds formed at the interface between Sn-Ag-Cu solder and NiP pads. At the interface of NiP pads and Sn-Ag-Cu solder, compounds such as (Ni,Cu)3Sn4 and (Cu,Ni)6Sn5 grow, and surface analysis using EDX shows the distribution of Ni, Cu, and Sn within these compounds. The EBSD method is a technique that analyzes based on the crystallographic information of the sample. By combining it with elemental analysis using EDX, it is possible to estimate the composition, and in some cases, it may be possible to analyze using crystallographic data for Ni3Sn4 and Cu6Sn5 as substitutes.
The EBSD method allows for the estimation of crystal size distribution and residual stress.
- Analytical Equipment and Devices
- Analysis Services

Example of analysis of compounds at the SAC solder and Ni pad interface.
We will introduce an example of the analysis of compounds formed at the interface between Sn-Ag-Cu solder and NiP pads. At the interface of NiP pads and Sn-Ag-Cu solder, compounds such as (Ni,Cu)3Sn4 and (Cu,Ni)6Sn5 grow, and surface analysis using EDX shows the distribution of Ni, Cu, and Sn within these compounds. The EBSD method is a technique that analyzes based on the crystallographic information of the sample. By combining it with elemental analysis using EDX, it is possible to estimate the composition, and in some cases, it may be possible to analyze using crystallographic data for Ni3Sn4 and Cu6Sn5 as substitutes.
Observing crystal structures with EBSD! Data can be obtained for each metal.
- Analytical Equipment and Devices
- Analysis Services

Example of analysis of compounds at the SAC solder and Ni pad interface.
We will introduce an example of the analysis of compounds formed at the interface between Sn-Ag-Cu solder and NiP pads. At the interface of NiP pads and Sn-Ag-Cu solder, compounds such as (Ni,Cu)3Sn4 and (Cu,Ni)6Sn5 grow, and surface analysis using EDX shows the distribution of Ni, Cu, and Sn within these compounds. The EBSD method is a technique that analyzes based on the crystallographic information of the sample. By combining it with elemental analysis using EDX, it is possible to estimate the composition, and in some cases, it may be possible to analyze using crystallographic data for Ni3Sn4 and Cu6Sn5 as substitutes.
Changes in crystal orientation and crystal grain size can be analyzed! We introduce the EBSD (Electron Backscatter Diffraction) method.
- Analytical Equipment and Devices
- Analysis Services

Example of analysis of compounds at the SAC solder and Ni pad interface.
We will introduce an example of the analysis of compounds formed at the interface between Sn-Ag-Cu solder and NiP pads. At the interface of NiP pads and Sn-Ag-Cu solder, compounds such as (Ni,Cu)3Sn4 and (Cu,Ni)6Sn5 grow, and surface analysis using EDX shows the distribution of Ni, Cu, and Sn within these compounds. The EBSD method is a technique that analyzes based on the crystallographic information of the sample. By combining it with elemental analysis using EDX, it is possible to estimate the composition, and in some cases, it may be possible to analyze using crystallographic data for Ni3Sn4 and Cu6Sn5 as substitutes.
Since semiconductors have different physical properties, new methods are required for failure analysis!
- Analysis Services
- Contract Analysis

Announcement of the introduction of Talos F200E
Our company will introduce the FEI "Talos F200E" transmission electron microscope system. Compared to conventional models, the resolution for TEM and STEM has improved, and performance has been significantly enhanced, allowing for EDS analysis with four detectors. Additionally, it is equipped with features such as drift-corrected frame integration (DCFI), which accumulates multiple frames while correcting for drift.
We will introduce a comparison of brightness and characteristics between good products and ESD-damaged products, along with examples of luminescence analysis using EMS microscopy!
- Analysis Services
- Contract Analysis
Shorter delivery time than his method! Both shape observation using FIB-SEM and diffusion layer observation can be performed!
- Analysis Services
- Contract Analysis

Power device failure location / Slice & View three-dimensional reconstruction
I will introduce the three-dimensional reconstruction of failure locations using the Slice & View function of FIB-SEM. Continuous SEM images of the structure are obtained, and the resulting images are corrected for positional misalignment between the SEM images and visualized in three dimensions using 3D construction software (Avizo). By combining the position identification technique for cross-sectioning the failure location with the Slice & View function, it is possible to obtain continuous SEM images that retain the defective state and include information before and after the abnormal area.
EELS analysis for element identification allows for the comparison of the bonding states of materials!
- Analysis Services
- Contract Analysis
"SEM images" and "absorption current images (current sensing)" etc.! It identifies open defects in wiring and areas with high resistance defects.
- Analysis Services
- Contract Analysis
The inspector observes without missing anything! Consistent whisker evaluation is possible from reliability testing to analysis.
- Analysis Services
- Contract Analysis

Appearance observation and measurement services
We would like to introduce our "Appearance Observation and Measurement Service." We are equipped with a variety of devices to meet your needs, including appearance observation before and after reliability testing, solder joint observation, as well as dimensional measurements and surface roughness measurements of various components. You can also leave the pre-observation processing to us. Our company has IPC-certified IPC specialists on staff. We provide assistance with observations, consultations, and solutions to various observation-related concerns in accordance with international standards.
We will introduce EBSD analysis that reveals areas where distortion has accumulated in the wiring of the bending section!
- Analysis Services
- Contract Analysis
We will narrow down the defective areas through lighting confirmation, panel disassembly, and optical microscope observation!
- Analysis Services
- Contract Analysis

Observation of Conductive Particle Shape in COG Implementation
We will introduce the observation of the shape of conductive particles in COG implementation. ICs and liquid crystal panels are implemented using the COG method with ACF (anisotropic conductive film). A resin ball is used as the core, and a metal layer (such as nickel or gold) for conductivity is deposited on its surface. During connection, the particles deform appropriately to electrically connect the IC and the panel. To confirm the degree of particle deformation and connection status, cross-sectional observations were conducted, revealing that the particle deformation was at a "medium" level, indicating an appropriate degree of deformation. By examining the deformation of conductive particles from both the planar and cross-sectional directions, we can explore the correlation with display defects. Please feel free to contact us for any inquiries regarding panel-related defects.
Analysis of inorganic compounds such as metal oxides is also possible! We will introduce the analysis of black spots on the surface of copper-clad laminates.
- Analysis Services
- Contract Analysis

Chemical Analysis Concierge Service
We would like to introduce our "Chemical Analysis - Trust Us Service." When conducting component analysis of foreign substances or stains on products, it can be challenging to determine whether organic analysis or inorganic analysis is more suitable, and which specific analysis within organic or inorganic is the most appropriate. We provide a comprehensive service for customers who are struggling with the selection of analysis methods. Since each analysis device can measure different targets, it is necessary to choose a method that fits the purpose based on the information available.
Useful for long-term quality control! Ultra-microhardness measurement of materials such as metals, polymers, and ceramics.
- Contract Analysis
- Analysis Services

Tensile test
The "tensile test" is a test that measures the load and displacement (elongation) when a material is pulled at a constant speed, in order to determine the physical and mechanical properties of the material. By pulling the test specimen in a temperature-controlled chamber, it is possible to determine and understand the temperature dependence of these properties. Our company is capable of conducting material property tests under temperature-controlled conditions. We can also propose conditions tailored to the materials and properties you wish to measure. Please feel free to consult with us.
Non-destructive X-ray observation is effective for initial inspection! We will introduce examples of defect analysis.
- Analysis Services
- Contract Analysis